1. Einleitung
The KUAIQU KM61C and KM61B are advanced digital multimeters designed for professional electricians and DIY enthusiasts. They offer a wide range of measurement functions including AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Diode, Continuity, and Non-Contact Voltage (NCV) detection. The KM61C model features 6000 counts and additional functions like Frequency/Duty Cycle and Temperature measurement, while the KM61B offers 4000 counts. Both models incorporate True RMS for accurate readings and a clear LCD display with backlight for visibility in various conditions.
This manual provides essential information for the safe operation, setup, and maintenance of your KUAIQU digital multimeter. Please read it thoroughly before use.
2. Sicherheitshinweise
WARNING: To avoid possible electric shock, fire, or personal injury, please read all safety information before you use the product. Improper use of this meter can cause damage, shock, injury, or death.
- Always ensure the multimeter is in the correct function and range before connecting to a circuit.
- Do not exceed the maximum input values for any range. Both models are rated CAT III 600V.
- Prüfen Sie die Messleitungen vor Gebrauch auf beschädigte Isolierung oder freiliegendes Metall. Ersetzen Sie beschädigte Leitungen.
- Verwenden Sie das Messgerät nicht, wenn es beschädigt erscheint oder das Gehäuse geöffnet ist.
- Seien Sie vorsichtig im Umgang mit Vol.tagEs liegt über 30 V AC RMS, 42 V Spitze oder 60 V DC. Diese SpannungentagEs besteht die Gefahr eines Stromschlags.
- Keep your fingers behind the finger guards on the test probes during measurements.
- Vor Funktionsänderungen die Messleitungen aus dem Stromkreis entfernen.
- Betreiben Sie das Messgerät nicht in der Nähe von explosiven Gasen, Dämpfen oder Staub.
- Always turn off the power to the circuit under test before measuring resistance, capacitance, or continuity.

3. Packungsinhalt
Upon opening your product box, please verify that all items listed below are present and in good condition.
For KM61C Model:
- 1 x KUAIQU KM61C Digital Multimeter
- 1 x Pair of Multimeter Test Probes (Red and Black)
- 1 x Temperaturfühler
- 1 x Farbbox.

For KM61B Model:
- 1 x KUAIQU KM61B Digital Multimeter
- 1 x Pair of Multimeter Test Probes (Red and Black)
- 1 x Farbbox.

4. Produktüberschreitungview
Familiarize yourself with the components of your digital multimeter:

Schlüsselkomponenten:
- LCD Anzeige: Zeigt Messwerte, Einheiten und Funktionsindikatoren an.
- Funktionsauswahlknopf: Rotary switch to select the desired measurement function (e.g., Voltage, Widerstand, Stromstärke).
- Funktionstaste (FUNC): Used to switch between AC/DC modes or other sub-functions within a main setting.
- Halte den Knopf: Locks the current display reading.
- Max Button: Zeigt den maximal gemessenen Wert an.
- Taschenlampen-/Hintergrundbeleuchtungstaste: Press for backlight, press and hold for flashlight.
- Eingangsklemmen:
- 10A Stromeingangsanschluss: Zur Messung von Strömen bis zu 10 A.
- COM (Common) Input Terminal: The negative (-) input for all measurements.
- Other Measurement Input Terminals: Für voltage, resistance, capacitance, diode, continuity, and temperature measurements.
- NCV Detection Indicator Light: Illuminates during Non-Contact Voltage Erkennung.
5. Einrichtung
5.1 Einlegen der Batterie
The multimeter requires batteries for operation (not included). Typically, these multimeters use AAA batteries. To install:
- Stellen Sie sicher, dass das Multimeter ausgeschaltet ist und trennen Sie alle Messleitungen.
- Suchen Sie den Batteriefachdeckel auf der Rückseite des Messgeräts.
- Die Befestigungsschraube(n) lösen und die Abdeckung abnehmen.
- Legen Sie die Batterien unter Beachtung der richtigen Polarität (+ und -) ein.
- Bringen Sie die Abdeckung des Batteriefachs wieder an und ziehen Sie die Schraube(n) fest.
5.2 Anschließen der Testleitungen
Always connect the black test lead to the COM terminal. Connect the red test lead to the appropriate input terminal based on the desired measurement:
- Für Bdtage, Resistance, Capacitance, Diode, Continuity, and Temperature: Connect the red lead to the VΩHz%mAµA terminal.
- For Current (up to 10A): Connect the red lead to the 10A terminal.
6. Bedienungsanleitung
6.1 Allgemeine Bedienung
- Ein-/Ausschalten: Turn the Function Selection Knob from "OFF" to any desired function to power on. Turn to "OFF" to power off. The meter features auto-shutdown to conserve battery.
- Funktionsauswahl: Rotate the Function Selection Knob to the desired measurement type (e.g., V~ for AC Voltage, V- für Gleichstromvoltage, Ω für Widerstand).
- Sub-Function Selection (FUNC button): For functions with multiple modes (e.g., AC/DC Voltage, Diode/Continuity), press the "FUNC" button to toggle between them.
- Data Hold (HOLD button): Press "HOLD" to freeze the current reading on the display. Press again to release.
- Maximum Value (MAX button): Press "MAX" to capture and display the maximum measured value.
- Hintergrundbeleuchtung/Taschenlampe: Press the backlight button (light bulb icon) to turn on/off the display backlight. Press and hold the button to activate the flashlight.

6.2 Spezielle Messmodi
Always ensure the test leads are correctly connected and the function knob is set to the appropriate measurement type before proceeding.
- AC/DC-Voltage Messung (V~ / V-):
- Set the function knob to V~ (AC) or V- (DC).
- Connect the test leads in parallel to the power supply or circuit being tested.
- Lesen Sie den Bandtage-Wert auf dem Display.

Abbildung 6: AC Voltage Messung example. - AC/DC Current Measurement (A~ / A-):
- Set the function knob to A~ (AC) or A- (DC).
- Schließen Sie die Prüfleitungen in Reihe mit dem Schaltkreis an.
- Lesen Sie den aktuellen Wert auf dem Display ab.
- Widerstandsmessung (Ω):
- Schalten Sie die Stromzufuhr zum Stromkreis aus.
- Set the function knob to Ω.
- Schließen Sie die Messleitungen an das Bauteil an, um den Widerstand zu messen.
- Lesen Sie den Widerstandswert ab.
- Capacitance Measurement (mF):
- Turn off power to the circuit and discharge the capacitor.
- Set the function knob to mF.
- Schließen Sie die Messleitungen an den Kondensator an.
- Lesen Sie den Kapazitätswert ab.
- Frequency/Duty Cycle Measurement (Hz%) (KM61C only):
- Set the function knob to Hz%.
- Schließen Sie die Testleitungen an die Signalquelle an.
- Read the frequency or duty cycle value.
- Temperature Measurement (°C/°F) (KM61C only):
- Set the function knob to °C/°F.
- Connect the temperature probe to the input terminals.
- Place the probe tip on the object to measure its temperature.
- Lesen Sie den Temperaturwert ab.
- Diodentest (
):- Schalten Sie die Stromzufuhr zum Stromkreis aus.
- Set the function knob to the Diode/Continuity position and press FUNC to select Diode.
- Verbinden Sie die rote Leitung mit der Anode und die schwarze Leitung mit der Kathode der Diode.
- Lesen Sie das Vorwort voltage drop. Vertauschen Sie die Anschlüsse, um auf einen offenen Stromkreis zu prüfen.
- Durchgangsprüfung (
):- Schalten Sie die Stromzufuhr zum Stromkreis aus.
- Set the function knob to the Diode/Continuity position and press FUNC to select Continuity.
- Schließen Sie die Messleitungen an den Stromkreis oder das Bauteil an.
- A buzzer will sound if continuity is detected (resistance below a certain threshold).
- Kontaktloses Volumentage (NCV)-Erkennung:
- Set the function knob to NCV.
- Move the top part of the meter near the conductor or outlet.
- The NCV indicator light will illuminate and a buzzer will sound if AC voltage wird erkannt.

Abbildung 7: NCV-Nichtkontakt-Volumentage detection example.
7. Spezifikationen
Below is a detailed comparison of the KUAIQU KM61C and KM61B models, along with general specifications.
7.1 Allgemeine Spezifikationen:
- Brand Name: KUAIQU
- DIY Lieferungen: Elektrisch
- Anzeigetyp: Digitalanzeige
- Operating Mode: Auto-Ranging
- Zertifizierung: CE, FCC, RoHS
- Herkunft: Festlandchina
- Battery Included: No (User-supplied)
- Hochbesorgniserregende Chemikalie: Keine
- Data Record: Yes
- Product Dimensions (approx.): 145mm (5.7in) H x 68mm (2.7in) W x 30mm (1.2in) D

7.2 Model-Specific Specifications:
| Besonderheit | KM61C (6000 Counts) | KM61B (4000 Counts) |
|---|---|---|
| Max. Anzahl | 6000 | 4000 |
| Echter Effektivwert | Ja | Ja |
| AC/DC-Voltage | 600 V | 600 V |
| AC / DC-Strom | 10 A | 10 A |
| Widerstand | 60 MΩ | 40 MΩ |
| Kapazität | 100 mF | 4 mF |
| Frequenz | 10 MHz | N / A |
| Arbeitszyklus | 1 % bis 99 % | N / A |
| Temperatur | -20°C bis 1000°C | -20°C bis 1000°C |
| Diodentest | Ja | Ja |
| Durchgangsprüfung | Yes (Buzzer Alarm) | Yes (Buzzer Alarm) |
| NCV | Yes (Buzzer Alarm) | Yes (Buzzer Alarm) |
| AC-Bandbreite | 1 kHz | 1 kHz |
| Daten halten | Ja | Ja |
| Taschenlampe | Ja | Ja |
| LCD High-definition Display | Ja | Ja |

8. Wartung
8.1 Reinigung
- Löschen Sie den Fall mit Anzeigeamp Tuch und mildem Reinigungsmittel. Keine Scheuer- oder Lösungsmittel verwenden.
- Halten Sie die Eingangsanschlüsse frei von Schmutz und Feuchtigkeit.
8.2 Batteriewechsel
Wenn die niedrige Lautstärketage indicator appears on the display, replace the batteries immediately to ensure accurate readings and proper operation. Follow the battery installation steps in Section 5.1.
8.3 Test Lead Care
- Regularly inspect test leads for any signs of damage, such as cuts, cracks, or exposed wiring.
- Replace damaged test leads immediately to prevent electric shock.
- Store test leads properly to avoid kinks or damage.
9. Fehlerbehebung
If your multimeter is not functioning as expected, refer to the following common issues and solutions:
- Keine Anzeige/Schwache Anzeige:
- Überprüfen Sie den Batterieeinbau und stellen Sie sicher, dass die Batterien nicht entladen sind. Tauschen Sie sie gegebenenfalls aus.
- Ensure the function knob is turned ON.
- Falsche Messwerte:
- Vergewissern Sie sich, dass die richtige Funktion und der richtige Messbereich ausgewählt sind.
- Check test lead connections for proper insertion and good contact.
- Ensure the circuit under test is powered off when measuring resistance, capacitance, or continuity.
- For True RMS models, ensure the signal is within the specified AC bandwidth (1kHz).
- Kein Kontinuitätssignal:
- Ensure the function knob is set to Continuity mode.
- Check if the circuit or component has high resistance, which would prevent the beep.
- NCV erkennt keine Lautstärketage:
- Ensure the function knob is set to NCV mode.
- Bestätigen Sie das Vorhandensein von AC vol.tage im Testgebiet.
If the problem persists after checking these points, contact customer support for further assistance.
10. Benutzertipps
- Immer mit einem hohen Start beginnen: Bei der Messung eines unbekannten VoltagBei Stromstärke oder E-Zahlen sollten Sie mit der höchsten Einstellung beginnen und sich schrittweise nach unten vorarbeiten, um eine Überlastung des Messgeräts zu vermeiden.
- Überprüfen Sie die Batterien regelmäßig: Eine schwache Batterie kann zu ungenauen Messwerten führen. Tauschen Sie die Batterien umgehend aus, sobald die Anzeige für niedrigen Batteriestand aufleuchtet.
- Richtige Lagerung: Store your multimeter in a dry, clean environment away from extreme temperatures and direct sunlight.
- Nutzen Sie NCV für Schnellprüfungen: The NCV function is excellent for quickly checking if a wire or outlet is live before performing more detailed measurements.
- Den wahren Effektivwert verstehen: True RMS multimeters provide accurate readings for both sinusoidal and non-sinusoidal AC waveforms, which is important in modern electronics.
11. Garantie und Support
For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact the KUAIQU customer service directly. Keep your purchase receipt as proof of purchase.
Zusätzliche Unterstützung und häufig gestellte Fragen finden Sie oft auf der offiziellen Website des Herstellers. webWebsite oder über die Supportkanäle des Verkäufers.