Einführung
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Wayne SWS75 0.75 HP Shallow Well Jet Pump. Please read these instructions thoroughly before use to ensure proper function and longevity of the pump.

Image: Wayne Shallow Well Jet Pump branding banner.
Sicherheitshinweise
Always observe safety precautions to reduce the risk of injury, electric shock, or property damage. This pump operates with electricity and water, which can be hazardous if not handled correctly.
- Elektrische Sicherheit: Ensure all electrical connections comply with local codes. The motor is thermally protected to prevent overheating; however, proper wiring is crucial.
- Wassersicherheit: Do not operate the pump dry. Ensure the pump is properly primed before starting.
- Installation: Follow all installation instructions carefully. Improper installation can lead to pump failure or safety hazards.
- Wartung: Vor jeglichen Wartungs- oder Servicearbeiten die Stromzufuhr unterbrechen.
Produkt überview
The Wayne SWS75 is a 0.75 horsepower shallow well jet pump designed for wells up to 25 feet deep. It features a durable cast iron volute and an efficient square flange motor that is thermally protected to prevent overheating.

Bild: Vorderseite view of the Wayne SWS75 0.75 HP Shallow Well Jet Pump.
Hauptmerkmale:
- Leistung: 0.75 PS
- Max Flussrate: 510 gallons per hour (GPH) at 50 PSI
- Well Depth: Suitable for wells 0 ft. to 25 ft. in depth
- Entladung: 3/4 Zoll NPT
- Saugen: 1-1/4 Zoll NPT
- Druckschalter: Pre-set at 30-50 PSI for automatic operation
- Konstruktion: Durable cast iron volute with a dedicated priming port
- Motor: Efficient square flange motor, thermally protected
- Montage: Assembled in the USA with foreign and domestic parts.

Image: Diagram highlighting key features of the Wayne SWS75 pump, including USA assembly, self-priming, dual voltage, and intake/discharge sizes.
Setup und Installation
Proper installation is critical for the performance and safety of your pump. Consult a qualified professional if you are unsure about any steps.
1. Location and Mounting:
- Install the pump on a solid, level surface to minimize vibration.
- Ensure the pump is protected from freezing temperatures and direct weather exposure.
- The pump is designed for shallow wells up to 25 feet deep.
2. Plumbing Connections:
- Connect the suction line to the 1-1/4 inch NPT intake port.
- Connect the discharge line to the 3/4 inch NPT discharge port.
- Use appropriate pipe sealant on all threaded connections to prevent leaks.
- Ensure all piping is adequately supported to avoid strain on the pump.
3. Ansaugen der Pumpe:
Before initial operation, the pump must be properly primed.
- Remove the priming plug located on the pump volute.
- Fill the pump volute completely with water through the dedicated priming port until water overflows.
- Setzen Sie den Ansaugstopfen wieder fest ein.
- Ensure the suction line is also filled with water to the well.
4. Elektrischer Anschluss:
- The pump operates on 120 Volts and is dual voltage 120V/240V capable. Ensure your power supply matches the pump's configuration.
- Connect the pump to a dedicated, properly grounded electrical circuit.
- Consult a licensed electrician for wiring if you are not familiar with electrical installations.
Bedienungsanleitung
Nach der Installation und dem Befüllen ist die Pumpe betriebsbereit.
- Erstinbetriebnahme: Turn on the power supply to the pump. The pump should start and begin to build pressure.
- Automatische Operation: The integrated pressure switch is pre-set to turn the pump on at 30 PSI and off at 50 PSI, maintaining consistent water pressure.
- Überwachung: Observe the pressure gauge (if installed) to ensure the pump is operating within the expected pressure range.
- Dauerbetrieb: The pump is designed for intermittent use as demand requires. Avoid prolonged dry running.
Wartung
Regelmäßige Wartung gewährleistet optimale Leistung und verlängert die Lebensdauer Ihrer Pumpe.
- Stromversorgung trennen: Vor jeglichen Wartungsarbeiten muss die Stromversorgung unterbrochen werden.
- Verbindungen prüfen: Überprüfen Sie regelmäßig alle Wasser- und Elektroanschlüsse auf Undichtigkeiten oder Korrosion. Ziehen Sie sie gegebenenfalls fest.
- Lüftungsschlitze reinigen: Ensure motor cooling vents are clear of debris to prevent overheating.
- Überwinterung: In areas subject to freezing temperatures, drain the pump and piping completely to prevent damage.
Fehlerbehebung
In diesem Abschnitt werden häufig auftretende Probleme behandelt, die bei Ihrer Pumpe auftreten können.
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Pumpe läuft, aber es kommt kein Wasser oder der Wasserdruck ist niedrig. |
|
|
| Pumpenzyklen zu häufig |
|
|
| Pumpe startet nicht |
|
|
Technische Daten
Detailed technical specifications for the Wayne SWS75 0.75 HP Shallow Well Jet Pump.
| Modell | SWS75 |
| PS | 0.75 PS |
| Maximaler Durchfluss | 510 GPH (at 50 PSI) |
| Maximale Hubhöhe | 25 Fuß |
| Bandtage | 120 Volts (Dual voltage 120V/240V capable) |
| Entladungsgröße | 3/4 Zoll NPT |
| Sauggröße | 1-1/4 Zoll NPT |
| Druckschaltereinstellung | 30-50 PSI (Pre-set) |
| Material | Gusseisen |
| Artikelgewicht | 38.6 Pfund |
| Produktabmessungen (L x B x H) | 22.3" x 11.5" x 10.3" |
Performance Data (Gallons Per Hour - GPH):

Image: Performance table showing GPH at various depths (0', 5', 10', 15', 20', 25') for 30, 40, and 50 PSI.
| PSI | 0' Depth (GPH) | 5' Depth (GPH) | 10' Depth (GPH) | 15' Depth (GPH) | 20' Depth (GPH) | 25' Depth (GPH) |
|---|---|---|---|---|---|---|
| 30 | 779 | 750 | 721 | 691 | 662 | 633 |
| 40 | 644 | 615 | 586 | 557 | 528 | 499 |
| 50 | 510 | 481 | 451 | 422 | 393 | 364 |
Garantieinformationen
The Wayne SWS75 Well Jet Pump comes with a 3 Jahr eingeschränkte Garantie covering parts only. Please retain your proof of purchase for warranty claims. For full warranty terms and conditions, refer to the documentation included with your product or visit the manufacturer's webWebsite.
Kundenservice
For technical assistance, replacement parts, or further inquiries, please contact Wayne customer support. Contact details can typically be found on the manufacturer's official webvor Ort oder in den Verpackungsmaterialien.
Note: Always provide your pump's model number (SWS75) and serial number when contacting support.