Eltako ES12Z-200

Eltako ES12Z-200 Modulares Impulsrelais – Benutzerhandbuch

Model: ES12Z-200 | Brand: Eltako

1. Einleitung

The Eltako ES12Z-200 is a modular impulse relay designed for inline installation on a DIN-EN 50 022 rail. This device features galvanically isolated working contacts and centralized control inputs, allowing for local control with a different phase and voltage than the centralized system. It includes a rotary switch for setting different priorities between control inputs and determining the device's behavior (switch off or maintain position) after a power failure.

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Eltako ES12Z-200 impulse relay.

2. Hauptmerkmale

  • Modular design for DIN rail mounting (1 module unit = 18mm wide).
  • Wide control voltage range: 8 to 230 V AC/DC.
  • Galvanically isolated control inputs for flexible local and centralized control.
  • Integrated rotary switch for priority selection and power failure behavior.
  • Two normally open (NO) contacts.
  • Rated current: 16 A.

3. Technische Daten

SpezifikationWert
HerstellerEltako
ModellnummerES12Z-200 (21200601)
MontagetypDIN-Schiene
Width in Module Units1 (18 mm)
Number of Normally Open Contacts (NO)2
Kontrolllautstärketage Reichweite8 bis 230 V AC / DC
Nennstrom16 A
BetriebsartEIN-AUS
Produktabmessungen (L x B x H)9.5 x 6 x 2.5 cm
Gewicht70 Gramm
MaterialNeon (for indicator lamp)
Verfügbarkeit von ErsatzteilenInformationen nicht verfügbar

4. Sicherheitshinweise

WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified electricians in accordance with all national and local electrical codes and regulations.

  • Vor der Installation, Wartung oder dem Ausbau des Geräts muss immer die Stromzufuhr unterbrochen werden.
  • Sorgen Sie für ordnungsgemäße Erdung und Verdrahtungsanschlüsse.
  • Überschreiten Sie nicht das angegebene Volumentage und Stromstärken.
  • Schützen Sie das Gerät vor Feuchtigkeit, Staub und extremen Temperaturen.
  • Überprüfen Sie, ob alle Verbindungen sicher sind, bevor Sie die Stromversorgung wiederherstellen.

5. Installation

5.1 Montage

The Eltako ES12Z-200 is designed for mounting on a standard DIN-EN 50 022 rail. Ensure sufficient space for ventilation and access to terminals.

5.2 Schaltplan

Refer to the wiring diagram below for correct electrical connections. The device supports both local and centralized control inputs with galvanic isolation.

Wiring diagram for Eltako ES12Z-200 impulse relay showing connections for L, N, control inputs (local, central on, central off), and output contacts.

Bild 1: Wiring diagram for the Eltako ES12Z-200 impulse relay. This diagram illustrates the connections for the main power supply (L, N), local control input, centralized control inputs (central on, central off), and the output contacts (1, 2). It also shows the internal circuitry for the control voltage and the 16A/250V output rating.

5.3 Verbindungsschritte

  1. Stromversorgung: Connect the live (L) and neutral (N) wires to the designated terminals as shown in the diagram. The device operates with a supply voltage range of 8-230V AC/DC.
  2. Lokale Steuerung: Connect your local push-button or switch to the 'local on/off' input. This input typically requires a control current of up to 150mA for neon lamps from 110V.
  3. Zentralisierte Steuerung: Connect centralized 'on' and 'off' control signals to the respective terminals. These inputs are galvanically isolated, allowing for different control voltages oder Phasen.
  4. Ausgangskontakte: Connect the load (e.g., lighting circuit) to the output contacts (1 and 2). The relay provides two normally open (NO) contacts with a maximum current rating of 16A at 250V.
  5. Überprüfung: Double-check all connections for correctness and security before applying power.

6. Bedienung

6.1 Grundlegende Funktionalität

The Eltako ES12Z-200 functions as an impulse relay. A brief pulse to any activated control input (local, central on) will toggle the state of the output contacts. A pulse to the central off input will switch the contacts to the OFF state.

6.2 Priority Selection and Power Failure Behavior

The device features a rotary switch on its front panel to configure priority settings for control inputs and define behavior during power failures.

Close-up of the Eltako ES12Z-200 rotary switch for priority selection and power failure settings.

Bild 2: Nahaufnahme view of the Eltako ES12Z-200 rotary switch. This switch allows users to select different priority levels for control inputs and configure the relay's response to power outages, such as switching off or maintaining its current state.

The rotary switch allows you to:

  • Set different priority levels for the various control inputs (e.g., local vs. centralized).
  • Determine the relay's state after a power failure: either switch off or maintain its last switching position upon power return. Consult the specific markings on your device for detailed settings.

7. Wartung

The Eltako ES12Z-200 impulse relay is designed for long-term, maintenance-free operation under normal conditions. However, periodic checks are recommended:

  • Sichtprüfung: Periodically inspect the device for any signs of physical damage, overheating, or loose connections.
  • Reinigung: Reinigen Sie die Außenseite des Geräts bei Bedarf vorsichtig mit einem trockenen, weichen Tuch. Verwenden Sie keine flüssigen Reiniger oder Lösungsmittel.
  • Anschlussdichtheit: Ensure all terminal screws remain tight to prevent poor contact and potential overheating.

Always disconnect power before performing any inspection or cleaning.

8. Fehlerbehebung

If you encounter issues with your Eltako ES12Z-200, refer to the following table for common problems and solutions:

ProblemMögliche UrsacheLösung
Relay does not respond to control input.No power supply; incorrect wiring; faulty control switch; control voltage outside range.Check power supply to L and N terminals. Verify all wiring connections against the diagram. Test the control switch. Ensure control voltage liegt im Bereich von 8-230V AC/DC.
Die Last schaltet nicht ein/aus.Faulty load; incorrect load wiring; overloaded contacts.Check the load (e.g., light bulb). Verify wiring to output contacts. Ensure load current does not exceed 16A.
Relay switches erratically.Interference; loose connections; faulty device.Check for sources of electrical interference. Tighten all terminal connections. If problem persists, the device may be faulty and require replacement.
Device gets excessively hot.Overloaded contacts; poor ventilation; loose connections.Reduce load if exceeding 16A. Ensure adequate ventilation around the device. Tighten all connections.

9. Garantie und Support

Information regarding a manufacturer's warranty for the Eltako ES12Z-200 is not explicitly provided. This product may be subject to the terms of a private sale without warranty, as indicated in some product descriptions. Additionally, information on the availability of spare parts is not available.

For any warranty claims or technical support, please contact your point of purchase or the seller directly. They can provide details on applicable return policies or support options.

10. Produktabmessungen

The Eltako ES12Z-200 is a compact device, designed to fit within standard electrical enclosures.

Image showing the Eltako ES12Z-200 impulse relay held in a hand, illustrating its compact size with dimensions of 2.6 inches (6 cm) in height.

Bild 3: The Eltako ES12Z-200 impulse relay shown in hand, providing a visual reference for its compact dimensions. The image highlights a height of approximately 2.6 inches (6 cm).

Zugehörige Dokumente - ES12Z-200

Vorview Eltako SU12DBT/1+1-UC: 2-Kanal-Bluetooth-Timer mit Display und App-Steuerung
Entdecken Sie den Eltako SU12DBT/1+1-UC, einen vielseitigen 2-Kanal-Timer mit Display, Bluetooth und ELTAKO Connect-App-Integration. Er verfügt über einen 16-A/250-V-Wechselstromkontakt, eine Astro-Funktion und eine DIN-Schienenmontage für eine effiziente elektrische Steuerung.
Vorview Eltako S2U12DDX-UC Digital-Timer mit Display: Benutzerhandbuch und technische Daten
Ausführlicher Leitfaden für die digitale Zeitschaltuhr Eltako S2U12DDX-UC mit Informationen zu Installation, Programmierung, Funktionen wie Astro-Funktion, Sommer-/Winterzeitumstellung und technischen Daten. Enthält Schaltpläne und Programmbeispiele.amples.
Vorview Eltako RS485 Bus Actuator FSR14SSR: Noiseless 2-Channel Impulse Switch Technical Manual
Comprehensive technical documentation for the Eltako FSR14SSR RS485 bus actuator, detailing its features, installation, configuration, wireless sensor integration, and typical connections for smart home automation.
Vorview Eltako SU12DBT/1+1-UC 2-Kanal Bluetooth-Timer: Benutzerhandbuch und technische Daten
Ausführliche Anleitung für die Eltako SU12DBT/1+1-UC 2-Kanal-Zeitschaltuhr mit Bluetooth. Erfahren Sie mehr über Installation, Einrichtung, Programmierung, Funktionen wie die Astro-Funktion und technische Daten.
Vorview Eltako TLZ12-8plus Treppenhausbeleuchtungs-Zeitschaltuhr – Technische Daten und Installationsanleitung
Ausführlicher Leitfaden zum Eltako TLZ12-8plus Treppenhauslicht-Zeitschalter mit Informationen zu Funktionen, technischen Daten, Multifunktionalität, Anschlussdiagrammen und Installationshinweisen für eine optimale Lichtsteuerung. Enthält detaillierte Erläuterungen zu Funktionen wie Abschaltwarnung und Dauerlicht per Knopfdruck.
Vorview Eltako ESR12NP-230V+UC Stromstoßschalter mit integrierter Relaisfunktion
Technische Daten und Bedienungsanleitung für den Eltako Impulsschalter ESR12NP-230V+UC mit integrierter Relaisfunktion. Details zu Installation, Funktionen, technischen Daten und Verdrahtung.