Watts 007 QT

Watts 007 QT 1/2-inch Double Check Valve Assembly Instruction Manual

1. Produktüberschreitungview

The Watts 007 QT 1/2-inch Double Check Valve Assembly is engineered to prevent the backflow of contaminated water into a potable water supply system. This device is suitable for non-health hazard, continuous pressure applications. Its robust bronze body construction ensures durability and ease of maintenance. The assembly provides protection against both backsiphonage and backpressure backflow, safeguarding water quality.

Zu den Hauptmerkmalen gehören:

Watts 007 QT 1/2-inch Double Check Valve Assembly

Image 1.1: Watts 007 QT 1/2-inch Double Check Valve Assembly. This image displays the bronze body construction and overall compact design of the valve assembly.

2. Sicherheitshinweise

WARNUNG: Improper installation or maintenance of this device can lead to serious injury or property damage. Always adhere to local plumbing codes and regulations.

3. Einrichtung und Installation

The Watts 007 QT Double Check Valve Assembly is designed for horizontal or vertical installation, depending on local codes and specific model requirements. Ensure proper orientation for optimal performance.

3.1 Prüfungen vor der Installation

3.2 Installationsschritte

  1. Wasserzufuhr abstellen: Locate the main water shut-off valve and turn off the water supply to the area where the backflow preventer will be installed. Drain the system to relieve pressure.
  2. Ort auswählen: Choose an accessible location for installation that allows for future maintenance and testing. The device should be installed downstream of the main water meter and upstream of any connections that could introduce contaminants.
  3. Rohrleitungen vorbereiten: Cut and prepare the existing piping to accommodate the 1/2-inch inlet and outlet connections of the valve assembly. Ensure pipe ends are clean and free of burrs.
  4. Ventil einbauen: Install the Watts 007 QT assembly into the pipeline, ensuring the flow arrow on the valve body points in the direction of water flow. Use appropriate thread sealant on all connections.
  5. Verbindungen festziehen: Securely tighten all connections to prevent leaks, but do not overtighten, which could damage the bronze body or fittings.
  6. Offene Wasserversorgung: Slowly open the main water shut-off valve to gradually repressurize the system. Check all connections for leaks.
  7. Erster Test: After installation, the device should be tested by a certified backflow prevention device tester to ensure proper operation and compliance with local regulations.

4. Bedienung

The Watts 007 QT Double Check Valve Assembly operates automatically to prevent backflow. It contains two independently operating check valves that close to prevent reverse flow when a backflow condition occurs.

5. Wartung

Regular maintenance and testing are crucial to ensure the continued proper function of your Watts 007 QT Double Check Valve Assembly. This device is designed for ease of service.

5.1 Jährliche Prüfung

Local regulations typically require annual testing of backflow prevention devices by a certified tester. This ensures the device is operating correctly and providing the required level of protection.

5.2 Wartung und Reparatur

The modular construction and top-entry design facilitate easy servicing. If testing indicates a malfunction, the internal components can be accessed and replaced without removing the entire assembly from the pipeline.

6. Fehlerbehebung

This section provides guidance for common issues. For complex problems or issues related to backflow prevention, always consult a certified professional.

6.1 Häufige Probleme und Lösungen

If you encounter issues not listed here or are unsure about a repair, contact Watts customer support or a qualified plumbing professional.

7. Spezifikationen

Modellnummer007 QT (Part # 0062131)
Größe1/2 Zoll
MaterialBronze, Silicone
AußenverkleidungBronze
Einlassanschlussgröße0.5 Zoll
EinlassverbindungstypDoppelrückschlagventilbaugruppe
Größe des Auslassanschlusses0.5 Zoll
AuslassanschlusstypFNPT
Maximaler Betriebsdruck175 psi (12.06 bar)
Anzahl der Ports2
Artikelgewicht3.45 Pfund
Produktabmessungen (L x B x H)1 x 0.39 x 0.39 Zoll
Spezifikation erfülltASSE 1015, AWWA C510, CSA B64.5, IAPMO PS31

8. Garantie und Support

For specific warranty information regarding your Watts 007 QT Double Check Valve Assembly, please refer to the documentation included with your purchase or visit the official Watts webDie Garantiebedingungen decken in der Regel Herstellungsfehler bei normalem Gebrauch und ordnungsgemäßer Wartung ab.

8.1 Kundendienst

If you require technical assistance, have questions about installation, operation, or maintenance, or need to inquire about replacement parts, please contact Watts customer support:

When contacting support, please have your product model number (007 QT) and any relevant purchase information readily available.

Zugehörige Dokumente - 007 QT

Vorview Watts Series 007, LF007 Double Check Valve Assemblies Installation, Maintenance, and Repair Manual
Comprehensive guide for installing, maintaining, and troubleshooting Watts Series 007 and LF007 Double Check Valve Assemblies. Includes safety warnings, installation procedures, servicing instructions, troubleshooting tips, and warranty information.
Vorview Watts Edelstahl-Doppelrückschlagventil-Kit GBS (007-SS-GBS) – Technische Daten
Technische Daten, Produktcodes, Abmessungen und Merkmale des Watts 007-SS-GBS Edelstahl-Doppelrückschlagventils mit Getriebe-Absperrklappe und Sieb. Entwickelt zur Rückflussverhinderung in Anlagen mit mittlerem und niedrigem Gefahrenpotenzial.
Vorview Watts-Doppelrückschlagventile der Serien 709, LF709 und 709DCDA: Installations-, Wartungs- und Reparaturhandbuch
Umfassender Leitfaden für die Installation, Wartung und Reparatur von Watts-Doppelrückschlagventilen der Serien 709, LF709 und 709DCDA sowie von Doppelrückschlagdetektoren für die Größen 2½" bis 10". Enthält Installationsrichtlinien, Wartungsanleitungen, Hinweise zur Fehlerbehebung und Informationen zu zusätzlichen Überwachungssätzen.
Vorview Watts Series 757, 757DCDA, LF757DCDA Double Check Valve Assemblies Installation, Maintenance, and Repair Manual
Comprehensive guide for installing, maintaining, and repairing Watts Series 757, 757DCDA, and LF757DCDA Double Check Valve and Detector Assemblies, covering procedures, troubleshooting, and warranty information.
Vorview Watts Series LF007 Double Check Valve Assembly: Installation, Maintenance, and Repair Manual
Comprehensive guide for the Watts Series LF007 Double Check Valve Assembly, covering installation, maintenance, troubleshooting, and warranty. Essential for ensuring safe and efficient water system operation.
Vorview Technische Daten des Watts 007-SS-LBS Edelstahl-Doppelrückschlagventils
Technisches Datenblatt für das Watts 007-SS-LBS Silver Stallion Edelstahl-Doppelrückschlagventil-Set mit Abmessungen, Produktcodes, technischen Spezifikationen und Kennlinien zum Schutz der Wasserversorgung.