Seco-Larm E-931-S35RRQ

Seco-Larm Enforcer E-931-S35RRQ Photoelectric Beam Sensor Instruction Manual

Model: E-931-S35RRQ

1. Einleitung

This manual provides detailed instructions for the installation, operation, and maintenance of the Seco-Larm Enforcer E-931-S35RRQ Photoelectric Beam Sensor. This device is designed for indoor and outdoor use to monitor entrances, secure perimeters, and detect obstructions by creating an invisible infrared beam. When the beam is broken, it triggers an alert (alarm device sold separately).

The sensor features a rugged, weatherproof enclosure, ensuring reliable performance in various environments.

2. Packungsinhalt

Überprüfen Sie, ob alle Komponenten im Paket vorhanden sind:

Seco-Larm Enforcer E-931-S35RRQ Photoelectric Beam Sensor and Reflector

Image 2.1: The Seco-Larm Enforcer E-931-S35RRQ Photoelectric Beam Sensor (right) and its accompanying reflector (left).

3. Installation und Einrichtung

Proper installation is crucial for optimal performance. The sensor and reflector should be mounted securely and aligned precisely.

3.1 Montage

Seco-Larm Enforcer E-931-S35RRQ Photoelectric Beam Sensor with attached cable

Bild 3.1: Nahaufnahme view of the sensor unit, showing the attached cable for power and signal connections.

3.2 Verkabelung

The sensor plugs into a standard power outlet. Connect the sensor to your security system or alarm device (sold separately) according to the wiring diagram provided with your alarm system. The sensor provides an SPDT (Single-Pole Double-Throw) relay output for triggering external devices.

3.3 Ausrichtung

Align the sensor and reflector to establish the infrared beam. The adjustable sensing distance allows for ranges up to 35 feet (11 meters). A yellow LED on the sensor indicates proper alignment. Adjust the position of the sensor and/or reflector until the yellow LED illuminates steadily, confirming the beam is established.

Close-up of the Seco-Larm Enforcer E-931-S35RRQ sensor showing LED indicators

Abbildung 3.2: Detailansicht view of the sensor's front face, highlighting the yellow alignment LED and red trigger LED.

4. Bedienung

Once installed and aligned, the Seco-Larm Enforcer E-931-S35RRQ operates by continuously emitting an infrared beam towards the reflector. The reflector bounces the beam back to the sensor. When an object breaks this invisible beam, the sensor's internal relay changes state, triggering the connected alarm or control device.

Seco-Larm Enforcer E-931-S35RRQ Photoelectric Beam Sensor and Reflector from a different angle

Image 4.1: The sensor and reflector units shown together, illustrating their relative positions for beam operation.

5. Wartung

The Seco-Larm Enforcer E-931-S35RRQ is designed for long-term reliability with minimal maintenance. Periodically inspect the sensor and reflector for any obstructions, dirt, or damage. Clean the lenses of both units with a soft, damp cloth to ensure clear beam transmission and reception. Ensure all mounting hardware remains secure.

6. Fehlerbehebung

If the sensor is not functioning as expected, consider the following:

7. Spezifikationen

ModellnummerE-931-S35RRQ
TypRetro-Reflective Photoelectric Sensor
Erfassungsbereich0.5' to 35' (0.1 - 11 m)
Bandtage Versorgung12~240VDC or 24~240VAC
Ansprechzeit10 ms (max.)
LichtquelleIR-LED
LED-AnzeigenYellow LED (Alignment), Red LED (Trigger)
Ausgabe auslösenSPDT Relay output
Schaltkapazität250VAC / 1A
SchutzartIP 66 Weatherproof
Umgebungstemperatur-4 ° - 131 ° F (-20 ° - 55 ° C)
Maße5.75 x 3.5 x 2 Zoll
Artikelgewicht11.2 Unzen (0.7 Pfund)
StromquelleKabelgebundene Elektrik
MontagetypWandhalterung

8. Garantie und Support

The Seco-Larm Enforcer E-931-S35RRQ Photoelectric Beam Sensor comes with a 1 Jahr eingeschränkte Garantie ab Kaufdatum. Diese Garantie deckt Material- und Verarbeitungsfehler bei normalem Gebrauch ab.

For technical support or warranty claims, please contact Seco-Larm customer service. Keep your proof of purchase for warranty validation.

Zugehörige Dokumente - E-931-S35RRQ

Vorview ENFORCER E-931-S50RRLQ 50ft Large Reflective Beam Sensor Manual
User manual for the SECO-LARM ENFORCER E-931-S50RRLQ 50ft Large Reflective Beam Sensor, covering features, specifications, installation, alignment, and troubleshooting.
Vorview ENFORCER E-921CPQ Voice Dialer Security System Component
Detailed information on the ENFORCER E-921CPQ Voice Dialer, a security system component by SECO-LARM. Features include user-recorded messages, remote listening/broadcasting, home mode, panic button, and a 105dB siren. Includes technical specifications, wiring diagram, and related products.
Vorview ENFORCER E-936-S45RRGQ Retroreflektierender Lichtschrankensensor – Installationsanleitung
Installationsanleitung für den retroreflektierenden Lichtschrankensensor ENFORCER E-936-S45RRGQ. Er bietet eine Reichweite von 45 m, Schutzart IP66 (wetterfest) und ist gemäß UL 325 für Torantriebe geeignet. Die Anleitung enthält Spezifikationen sowie Hinweise zu Installation, Justierung und Fehlerbehebung.
Vorview SECO-LARM E-941S Serie U-Halterungen für elektromagnetische Schlösser – Installationsanleitung
Montageanleitung für SECO-LARM E-941S-600/UQ und E-941S-1K2/UQ Glastür-U-Halterungen für elektromagnetische Schlösser. Enthält eine Teileliste.viewund eine schrittweise Installationsanleitung.
Vorview ENFORCER E-921CPQ Voice Dialer User Manual
User manual for the SECO-LARM ENFORCER E-921CPQ Voice Dialer, detailing its features, installation, programming, operation, and remote control capabilities for alarm systems.
Vorview SECO-LARM ENFORCER SH-525SQ/SH-905SQ Surface-Mount Dual-Tone Wall Siren or Speaker Manual
Installation manual and specifications for the SECO-LARM ENFORCER SH-525SQ and SH-905SQ surface-mount dual-tone wall siren or speaker. Includes features, parts list, specifications, overview, installation instructions, and wiring diagrams.