ESAB 0781-0589

ESAB SR-461B-510 LPG-Zylinder-Gasregler Bedienungsanleitung

Modell: 0781-0589

1. Einleitung

This manual provides essential instructions for the safe and effective installation, operation, and maintenance of your ESAB SR-461B-510 Industrial Gas Regulator. This single-stage regulator is designed for use with LP Gas cylinders, featuring a CGA-510 inlet connection and a 9/16 In.-18 M LH outlet connection.

Please read this manual thoroughly before attempting to install or operate the regulator. Retain this manual for future reference.

1.1. Sicherheitshinweise

WARNUNG: Misuse of this product may cause explosion and personal injury. Always read and understand all ASME-B40.100 standards and apparatus installation/operating instructions before using.

Dieses Produkt enthält Chemikalien, die dem Staat Kalifornien als krebserregend und fortpflanzungsschädigend bekannt sind (Warnung gemäß kalifornischer Proposition 65).

  • Always ensure proper ventilation when working with LP gas.
  • Never use oil or grease on regulator or cylinder connections.
  • Inspect the regulator and connections for damage before each use.
  • Use only with compatible LP gas cylinders and connections.
  • Do not modify the regulator in any way.

1.2. Packungsinhalt

  • ESAB SR-461B-510 Regulator Unit
  • Bedienungsanleitung (dieses Handbuch)

2. Einrichtung und Installation

Follow these steps for safe installation of the regulator to an LP gas cylinder.

  1. Ensure the cylinder valve is closed and the regulator adjusting screw is fully backed out (turned counter-clockwise until loose).
  2. Inspect the cylinder valve outlet and regulator inlet connection (CGA-510) for any damage or debris.
  3. Connect the regulator inlet nut to the cylinder valve outlet. The CGA-510 connection is designed for LP gas. Tighten securely with a wrench.
  4. Connect the outlet hose (not included) to the regulator's 9/16 In.-18 M LH outlet connection. Ensure this connection is also tight.
  5. Perform a leak test using a suitable leak detection solution on all connections before opening the cylinder valve.
ESAB SR-461B-510 LPG Cylinder Gas Regulator with two gauges and a T-handle adjusting screw.

Abbildung 1: ESAB SR-461B-510 LPG Cylinder Gas Regulator. This image displays the brass regulator body, two pressure gauges, and a T-handle adjusting screw. The inlet connection (CGA-510) is visible on the right, designed for LP gas cylinders. The left gauge, which in this image shows a scale for Acetylene (0-15 psi), would indicate the delivery pressure for LPG. The right gauge indicates the cylinder pressure (0-400 psi).

3. Bedienungsanleitung

Once the regulator is securely installed and leak-tested, follow these steps to operate.

  1. Slowly open the cylinder valve. The inlet gauge (right gauge, 0-400 psi) will indicate the cylinder pressure.
  2. Turn the regulator adjusting screw (T-handle) clockwise to increase the delivery pressure. The delivery pressure gauge (left gauge, 0-60 psig) will show the regulated pressure. Adjust to the desired working pressure, typically within the 2 to 40 psig range for this model.
  3. Once the desired pressure is set, you can begin using the LP gas.
  4. To shut down, first close the cylinder valve.
  5. Allow the gas in the system to bleed off until both gauges read zero.
  6. Turn the regulator adjusting screw counter-clockwise until it is loose to relieve spring tension.

The regulator is designed for a flow rate of approximately 2500 SCFH (Standard Cubic Feet per Hour).

4. Wartung

Regular maintenance ensures the longevity and safe operation of your regulator.

  • Inspektion: Before each use, visually inspect the regulator for any signs of damage, such as dents, cracks, or worn threads. Check gauges for proper function.
  • Reinigung: Keep the regulator clean and free from oil, grease, or other contaminants. Use a clean, dry cloth. Do not use harsh chemicals.
  • Dichtigkeitsprüfung: Periodically perform a leak test on all connections, even if no issues are suspected.
  • Lagerung: When not in use, store the regulator in a clean, dry place, disconnected from the cylinder.

Do not attempt to repair the regulator yourself. Refer all repairs to qualified personnel or contact ESAB customer support.

5. Fehlerbehebung

In diesem Abschnitt werden häufig auftretende Probleme behandelt.

  • Kein Gasfluss:
    • Ensure the cylinder valve is fully open.
    • Check if the cylinder contains gas.
    • Verify the regulator adjusting screw is turned clockwise to set a delivery pressure.
    • Inspect for blockages in the hose or equipment.
  • Druck hält nicht:
    • Perform a leak test on all connections (cylinder, regulator inlet, regulator outlet, hose).
    • Stellen Sie sicher, dass alle Verbindungen fest angezogen sind.
    • If leaks persist or the regulator itself is suspected, discontinue use and contact support.
  • Inaccurate Gauge Readings:
    • Gauges are factory calibrated. If readings appear consistently incorrect, the gauge may be faulty. Discontinue use and contact support.

For issues not covered here, or if troubleshooting steps do not resolve the problem, contact ESAB customer support.

6. Spezifikationen

BesonderheitDetail
Modellnummer0781-0589 (SR-461B-510)
ReglertypIndustrial Gas Regulator, Single Stage
Gas ServiceFlüssiggas (LPG)
EinlassanschlussCGA-510
Auslassanschluss9/16 In.-18 M LH
Delivery Pressure Range2 bis 40 psig
Delivery Pressure Gauge60 psig (2-1/2 In. Gauge Size)
Einlassmanometer400 psig (2-1/2 In. Gauge Size)
Durchflussrate (ca.)2500 l/h
MaterialGeschmiedetes Messing
Gesamtlänge7-1 / 4 In.
Technische Daten6 x 7 x 7 Zoll
Artikelgewicht5.13 Pfund
HerstellerVictor Technologies (ESAB)
UrsprungslandVereinigte Staaten

7. Garantie und Support

For warranty information, technical support, or service inquiries, please contact ESAB customer service directly. Refer to the official ESAB webDie aktuellsten Kontaktdaten finden Sie auf der Website oder der Produktverpackung.

When contacting support, please have your model number (0781-0589) and purchase information available.

Zugehörige Dokumente - 0781-0589

Vorview ESAB PP 350W Taschenlampe – Kurzanleitung – Einrichtung und Betrieb
Kurzanleitung für die Einrichtung und den Betrieb des ESAB PP 350W Schweißbrenners, einschließlich Anschluss, Einstellungen und Sicherheitsinformationen.
Vorview ESAB TRACFINDER WHEEL: Betjeningsvejledning og Teknisk Information
Zu diesem Zweck erhalten Sie eine ausführliche Anleitung für die Installation, den Antrieb, die Wartung und die Suche nach dem ESAB TRACFINDER WHEEL-Schwebetraktor. Erfahren Sie mehr über technische Spezifikationen, sichere Vorgehensweise und Vorteile.
Vorview ESAB LAF 1001 / LAF 1001M Bedienungsanleitung - Leitfaden für Schweißstromquellen
Ausführliche Bedienungsanleitung für die ferngesteuerten 3-Phasen-Schweißstromquellen ESAB LAF 1001 und LAF 1001M, die Installation, Betrieb, Wartung und Sicherheit bei mechanisierten Lichtbogenschweißanwendungen abdeckt.
Vorview Guía de funcionamiento del TRACFINDER WHEEL de ESAB
Manual de funcionamiento y guía de instalación para el carro de soldadura autónomo ESAB TRACFINDER WHEEL. Cubre especificaciones técnicas, operaciones, mantenimiento y solución de problemas.
Vorview ESAB TRACFINDER RAIL: Handbuch zur Bedienung und Installation
Dieses Handbuch enthält ausführliche Anweisungen zur Installation, Bedienung, Sicherheit, Bedienung und Lösung von Problemen mit dem automatischen Lötsystem ESAB TRACFINDER RAIL, das für industrielle Anwendungen entwickelt wurde.
Vorview ESAB Savage A41 Lashelm Gebruiksaanwijzing
Ontdek de ESAB Savage A41 lashelm: uw gids voor veiligheid, installatie en optimale prestaties. Deze handleiding biedt essentiële informatie voor professionele lassers, inclusief gedetailleerde instructies, technische specificaties en onderhoudstips voor uw laswerkzaamheden.