Einführung

The Altronix ACM8CB is an advanced 8-output access power controller module designed to manage power distribution for various access control devices. This module efficiently converts input voltage (12 to 24 Volt AC or DC) to provide regulated output power, ensuring reliable operation of connected equipment. It is built with durable phenolic or fiberglass material, offering robust performance in demanding environments.

Hauptmerkmale

Setup und Installation

Proper installation is crucial for the safe and efficient operation of the ACM8CB module. Always ensure power is disconnected before beginning any installation procedures.

  1. Montage: Securely mount the ACM8CB module within an appropriate enclosure, ensuring adequate ventilation. Use non-conductive standoffs if mounting directly to a metal surface.
  2. Stromanschluss: Connect the 12-24V AC or DC power source to the designated input terminals on the module. Observe correct polarity for DC input.
  3. Anschluss des Ausgabegeräts: Connect your access control devices (e.g., locks, readers, sensors) to the eight individual output terminals. Each output is clearly labeled (Output 1-8). Ensure correct wiring for each device as per its manufacturer's instructions.
  4. Trigger Input (Optional): If utilizing the trigger feature, connect the trigger source to the designated trigger input terminals. This allows for external control over the power outputs.
  5. Erdung: Ensure the module and all connected devices are properly grounded according to local electrical codes.
  6. Erstes Einschalten: After all connections are verified, apply power to the module. Observe the status indicators (LEDs) for proper operation.
Spitze view of Altronix ACM8CB power controller module with labeled terminals and components.

Abbildung 1: Oben view of the Altronix ACM8CB module, showing the input and output terminals, fuses, and LED indicators. Note the clearly marked output sections (Output 1-8) and the trigger input area.

Bedienungsanleitung

The ACM8CB module operates by distributing power to connected devices based on its configuration and trigger inputs.

Unterseite view of Altronix ACM8CB power controller module, showing circuit board details and components.

Abbildung 2: Unterseite view of the Altronix ACM8CB module, providing a closer look at the circuit board layout and various electronic components, including the PTCs (Positive Temperature Coefficient resettable fuses) and relays.

Wartung

The Altronix ACM8CB module is designed for minimal maintenance. However, periodic checks can ensure optimal performance and longevity.

Fehlerbehebung

ProblemMögliche UrsacheLösung
No power to any output.No input power; main fuse blown; faulty power supply.Verify input power connection and source. Check and replace the main fuse if necessary. Test the power supply.
Specific output not working.Blown output fuse; short circuit on output; faulty connected device.Check and replace the specific output fuse. Disconnect the device to check for short. Test the connected device.
LED indicators not illuminating.No power; faulty LED; module malfunction.Verify power input. If power is present and LEDs are off, contact technical support.
Module overheating.Overload on outputs; insufficient ventilation; internal fault.Reduce load on outputs. Ensure proper airflow around the module. If problem persists, contact technical support.

Technische Daten

AttributDetail
ModellnummerACM8CB
ProdukttypAccess Power Controller Module
Eingangslautstärketage12 to 24 Volt AC or DC
Ausgangsvolumentage12 to 24 Volt AC or DC
Anzahl der Ausgänge8
MaterialPhenolic or Fiberglass
Abmessungen (L x B x H)4.50 In x 8.00 In x 1.25 In
Gewicht11.18 Unzen
NormenUL RECOGNIZED, UL294
HerstellerALTRONIX
Datum der ersten Verfügbarkeit17. Dezember 2008

Garantie und Support

For warranty information and technical support regarding your Altronix ACM8CB module, please refer to the official Altronix website or contact their customer service department directly. Keep your purchase receipt and product serial number handy when seeking support.

Altronix provides comprehensive support for their products, including technical assistance and documentation. For the most up-to-date information, visit www.altronix.com.

Zugehörige Dokumente - ACM8CB

Vorview Altronix MaximalFD Series PTC Access Power Controllers Installation Guide
Installation guide for Altronix MaximalFD Series Single Power Supply Access Power Controllers (PTC), including Maximal3FD, Maximal5FD, and Maximal7FD models. Covers features, installation, maintenance, wiring, and specifications.
Vorview Installationsanleitung für Altronix/Honeywell ProWatch/WinPak-Kits – T2HWK78V, T2HWK78DV, T3HWK7516V, T3HWK7516DV
Ausführliche Installationsanleitung für Altronix- und Honeywell ProWatch/WinPak-Zutrittskontrollsysteme, einschließlich der Modelle T2HWK78V, T2HWK78DV, T3HWK7516V und T3HWK7516DV. Beinhaltet Produktinformationen zu folgenden Themen:viewKonfiguration, Installationsanleitung, Hardware und Gehäuseabmessungen.
Vorview Installationsanleitung für das Altronix T2PXK78 & T2PXK78D Trove Paxton Access & Power Integration Kit
Ausführliche Installationsanleitung für Altronix Trove Paxton-Kits (T2PXK78, T2PXK78D). Erfahren Sie, wie Sie fortschrittliche Zutrittskontroll- und Stromversorgungssysteme mit Altronix-Netzteilen, -Controllern und Paxton Net2 Plus-Modulen einrichten.
Vorview Installationsanleitung für das Altronix Trove Access & Power Integration Enclosure
Ausführliche Installationsanleitung für Altronix Trove1SA1- und Trove2SA2-Gehäuse mit Altronix/SALTO-Backplanes zur Integration von Zutrittskontroll- und Stromversorgungssystemen. Enthält Spezifikationen, Montagehinweise und Details zur Modulkonfiguration.
Vorview Installationshandbuch für Altronix Trove2/Mercury-Kits mit abgesicherten Ausgängen
Installationshandbuch für Altronix Trove2/Mercury-Kits mit detaillierten Informationen zu verschiedenen Modellen mit Sicherungsausgang, Konfigurationsoptionen und Montageanleitungen für Zugangskontrollsysteme. Enthält überview, Konfigurationsdiagramme, Installationsschritte und Gehäuseabmessungen.
Vorview Altronix DL1 Türsteuerungs-Timer: Spezifikationen und Installationsanleitung
Detaillierte Spezifikationen und Installationsanweisungen für den Altronix DL1 Türsteuerungs-Timer mit einstellbarer Zeitschaltuhr, Relaisausgang und vielseitiger Lautstärkeregelung.tage Betrieb.