Ozeri BP01K

Ozeri BP01K CardioTech Pro Series Digital Blood Pressure Monitor

Bedienungsanleitung

1. Einleitung

The Ozeri BP01K CardioTech Pro Series Digital Blood Pressure Monitor is designed for accurate and convenient measurement of blood pressure and pulse rate at the wrist. This device utilizes advanced technology to provide reliable readings and includes features for heart health monitoring, such as a hypertension indicator and irregular heartbeat detection. Please read this manual thoroughly before using the device to ensure correct operation and to understand all safety precautions.

Ozeri BP01K CardioTech Pro Series Digital Blood Pressure Monitor showing a reading of 120/80 mmHg

Bild 1.1: Vorderseite view of the Ozeri BP01K monitor displaying a blood pressure reading.

2. Sicherheitshinweise

3. Packungsinhalt

Bitte überprüfen Sie beim Auspacken, ob alle folgenden Artikel enthalten sind:

Contents of the Ozeri BP01K package including the monitor, carrying case, batteries, and user manual

Image 3.1: All components included in the Ozeri BP01K product package.

4. Produktmerkmale

5. Einrichtung

5.1 Einlegen der Batterie

  1. Suchen Sie das Batteriefach auf der Rückseite des Monitors.
  2. Schieben Sie die Batterieabdeckung ab.
  3. Legen Sie die beiden AAA-Batterien ein und achten Sie dabei auf die richtige Polarität (+/-), wie im Batteriefach angegeben.
  4. Setzen Sie die Batterieabdeckung wieder auf.

5.2 Manschettenplatzierung

Proper cuff placement is critical for accurate readings.

  1. Remove any tight clothing from your left wrist.
  2. Slide the monitor onto your left wrist with the display facing upwards. The cuff should be positioned approximately 1 cm (0.4 inches) from your hand.
  3. Secure the cuff snugly around your wrist using the hook-and-loop fastener. Ensure it is not too tight or too loose.
  4. Rest your elbow on a table so that the monitor is at the same level as your heart. Your palm should be facing upwards.
  5. Bleiben Sie während der Messung ruhig und vermeiden Sie es, zu sprechen.
Diagram on the Ozeri BP01K cuff showing correct wrist placement and distance from hand

Image 5.2: The wrist cuff with a diagram illustrating proper placement on the wrist.

6. Bedienungsanleitung

6.1 Messung durchführen

  1. Ensure the cuff is correctly placed on your wrist and your arm is positioned at heart level.
  2. Drücken Sie die START/STOP button. The cuff will begin to inflate automatically using MWI technology.
  3. Remain still and silent during the measurement. The device will deflate automatically once the measurement is complete.
  4. Your Systolic (SYS), Diastolic (DIA) blood pressure, and Pulse rate (PUL) will be displayed on the screen.
  5. The reading will automatically be stored in the device's memory.
  6. Drücken Sie die START/STOP button again to turn off the device, or it will automatically power off after a period of inactivity.

6.2 Speicherfunktionen

The monitor can store up to 180 readings (90 for User 1 and 90 for User 2).

  1. Zu view gespeicherte Messwerte, drücken Sie die MEM Drücken Sie die Taste, wenn das Gerät ausgeschaltet ist.
  2. Jedes Drücken der MEM button will cycle through the stored readings, displaying the most recent first.
  3. The device will also display the average of the last 3 readings.
  4. Um zwischen Benutzer 1- und Benutzer 2-Speicher umzuschalten, drücken Sie die Taste SATZ Taste während viewSpeicher.
  5. To clear all memory for the current user, press and hold the MEM button for approximately 5 seconds until 'CLR' appears on the display.

7. Ihre Lesetexte verstehen

7.1 WHO Hypertension Indicator

The monitor features a color-coded bar on the left side of the display, which visually indicates your blood pressure classification according to World Health Organization (WHO) guidelines:

This indicator provides a quick reference, but always consult a healthcare professional for a definitive diagnosis and treatment plan.

7.2 Irregular Heartbeat Detection

If an irregular heartbeat is detected during a measurement, a special symbol (often a heart icon with wavy lines) will appear on the display. This indicates that your heart rhythm was irregular during the measurement. While this feature can be an early warning, it is not a diagnostic tool. If this symbol appears frequently, consult your physician for further evaluation.

8. Wartung und Pflege

9. Fehlerbehebung

ProblemMögliche UrsacheLösung
Gerät lässt sich nicht einschaltenDie Batterien sind leer oder falsch eingelegt.Batteriepolung prüfen; durch neue AAA-Batterien ersetzen.
"E" or "Error" message on displayCuff not applied correctly; movement during measurement; speaking during measurement.Re-apply cuff correctly; remain still and silent during measurement; ensure wrist is at heart level.
Inkonsistente MesswerteImproper cuff placement; body movement; talking; recent activity (eating, smoking, exercise).Ensure proper cuff placement and body position; take measurements at the same time each day; avoid activity for 30 minutes prior.
Das Symbol für unregelmäßigen Herzschlag erscheint häufigActual irregular heartbeat detected.Bitte konsultieren Sie Ihren Arzt, um medizinischen Rat einzuholen.

10. Spezifikationen

BesonderheitSpezifikation
ModellnummerBP01K
MessmethodeOszillometrisch
AnzeigetypDigital LCD
MessbereichBlutdruck: 0–299 mmHg, Puls: 40–199 Schläge/Minute
GenauigkeitDruck: ±3 mmHg, Puls: ±5 % des Messwerts
Erinnerung180 readings (90 x 2 users)
Stromquelle2 x AAA-Batterien
Technische Daten7.62 x 8.89 x 8.89 cm
Artikelgewicht136.08 g (0.3 Pfund)
ManschettengrößeWrist circumference 13.5-21.5 cm (5.3-8.5 inches)

11. Garantie und Support

The Ozeri BP01K CardioTech Pro Series Digital Blood Pressure Monitor is backed by a 5 Jahr Garantie ab Kaufdatum. Diese Garantie deckt Material- und Verarbeitungsfehler bei normalem Gebrauch ab.

For warranty claims, technical support, or any questions regarding the operation of your device, please contact Ozeri customer service. Refer to the contact information provided on the product packaging or the official Ozeri webWebsite.

Bitte bewahren Sie Ihren Kaufbeleg für Garantiezwecke auf.

Zugehörige Dokumente - BP01K

Vorview Ozeri Touch II Ganzkörperwaage: Benutzerhandbuch und Funktionen
Ausführlicher Leitfaden zur Ozeri Touch II Ganzkörperwaage mit Informationen zu Einrichtung, Funktionen, Körperzusammensetzungsanalyse (Fett, Wasser, Muskeln, Knochen), Tara-Modus und Speicherprogramm.files und Garantieinformationen.
Vorview Ozeri Touch II Digitale Küchenwaage ZK013 – Benutzerhandbuch und Spezifikationen
Ausführliche Bedienungsanleitung für die digitale Küchenwaage Ozeri Touch II (Modell ZK013). Erfahren Sie mehr über technische Daten, Bedienung, Tara-Funktion, Batteriewechsel und Sicherheitshinweise für dieses präzise Küchenwaagen-Tool.
Vorview Ozeri Touch II Smart Body Scale: Benutzerhandbuch & Funktionen
Ein umfassender Leitfaden zur Ozeri Touch II Smart Body Scale (Modell ZB13, ZB13-W) mit detaillierten Informationen zu Einrichtung, Funktionen, Körperzusammensetzungsmessungen (Fett, Wasser, Muskeln, Knochen), Tara-Modus und Speicherfunktion.files und Garantieinformationen.
Vorview Ozeri Touch II Ganzkörperwaage – Benutzerhandbuch und Funktionen
Ausführlicher Leitfaden zur Ozeri Touch II Ganzkörperwaage mit Informationen zu Einrichtung, Funktionen, Messungen (Körperfett, Wasser, Muskeln, Knochen), Speicherprogrammenfiles, Tara-Modus und Garantieinformationen.
Vorview Ozeri Rev™ Digitale Badezimmerwaage – Benutzerhandbuch – ZB23-W
Benutzerhandbuch für die digitale Badezimmerwaage Ozeri Rev™ mit elektromechanischem Zifferblatt (Modell ZB23-W). Enthält Informationen zu Einrichtung, Verwendung, technischen Daten, Fehlerbehebung und Garantie.
Vorview Ozeri Rev Digitale Badezimmerwaage mit elektromechanischem Zifferblatt – Benutzerhandbuch (Modell ZB19)
Benutzerhandbuch für die digitale Badezimmerwaage Ozeri Rev mit elektromechanischem Zifferblatt, Modell ZB19. Enthält Informationen zu Einrichtung, Verwendung, technischen Daten, Fehlerbehebung und Garantie.