Star Y9529 / 52-1071

Star Y9529 Sicherheitspilotventil – Benutzerhandbuch

Model: Y9529 / 52-1071

1. Einleitung

This user manual provides essential information for the safe installation, operation, and maintenance of the Star Y9529 Safety Pilot Valve. This valve is designed for use with natural gas (NAT) or liquid propane (LP) systems, featuring a 3/8" FPT connection and manual pilot safety. It is rated for 140,000 BTU with a 1/4" CCT pilot out and includes pilot flame adjustment. Please read this manual thoroughly before installation or use.

2. Sicherheitshinweise

WARNUNG: Eine unsachgemäße Installation, Einstellung, Änderung, Wartung oder Instandhaltung kann zu Sachschäden, Verletzungen oder zum Tod führen. Lesen Sie die Installations-, Betriebs- und Wartungsanweisungen sorgfältig durch, bevor Sie dieses Gerät installieren oder warten.

3. Produktbeschreibung und Merkmale

The Star Y9529 Safety Pilot Valve is a critical component for gas-fired appliances, ensuring safe operation by controlling the gas flow to the pilot and main burner. Its robust design and precise engineering make it suitable for various commercial cooking equipment.

Star Y9529 Safety Pilot Valve

Figure 3.1: Star Y9529 Safety Pilot Valve. This image shows the compact design of the valve with its various connection points for gas lines.

Diagram of a Safety Pilot Valve

Figure 3.2: Schematic diagram of a typical safety pilot valve. This diagram illustrates the internal components and flow paths, including the inlet, outlet, and pilot gas connections.

Hauptmerkmale:

4. Einrichtung und Installation

Installation of the Star Y9529 Safety Pilot Valve should only be performed by a qualified and licensed professional, such as a gas technician or plumber, in accordance with all local codes and regulations.

Installationsschritte (Allgemeine Richtlinien):

  1. Turn off Gas Supply: Locate the main gas shut-off valve for the appliance or building and turn it to the "OFF" position.
  2. Bereich lüften: Sorgen Sie für eine gute Belüftung des Arbeitsbereichs.
  3. Disconnect Old Valve (if applicable): Carefully disconnect the existing pilot valve, noting the connections for the main gas line, pilot gas line, and thermocouple/thermopile.
  4. Verbindungen vorbereiten: Apply appropriate pipe thread sealant (suitable for gas) to the male threads of the gas lines that will connect to the new valve.
  5. Neues Ventil anschließen:
    • Connect the main gas supply line to the 3/8" FPT inlet of the Y9529 valve.
    • Connect the pilot gas line to the 1/4" CCT pilot out connection.
    • Connect the thermocouple or thermopile to the designated port on the valve. Ensure connections are snug but do not overtighten.
  6. Sicheres Ventil: Mount or secure the valve in its intended position within the appliance.
  7. Auf Lecks prüfen: After all connections are made, slowly turn on the main gas supply. Apply a soap and water solution to all new connections. Bubbles indicate a gas leak. If leaks are detected, turn off the gas, tighten connections, and re-test. Repeat until no leaks are present.
  8. Testbetrieb: Follow the appliance's specific instructions for lighting the pilot and main burner to ensure proper operation of the new valve.

5. Bedienungsanleitung

The Star Y9529 is a manual pilot safety valve. Its operation is integrated with the appliance it serves. Always refer to the specific operating instructions of your appliance for detailed lighting procedures.

General Pilot Lighting Procedure (Consult Appliance Manual for specifics):

  1. Ensure the appliance's main gas valve is in the "OFF" position.
  2. Locate the pilot light assembly.
  3. Press and hold the pilot button or knob on the gas control valve (often part of the pilot valve assembly). This allows gas to flow to the pilot.
  4. While holding the button, use a long lighter or match to ignite the pilot flame.
  5. Continue holding the pilot button for 30-60 seconds after ignition. This allows the thermocouple/thermopile to heat up and generate enough voltage to hold the pilot valve open.
  6. Release the pilot button. The pilot flame should remain lit. If it extinguishes, repeat the process.
  7. Once the pilot is stable, turn the main gas valve knob to the "ON" position to allow gas flow to the main burner.

Zündflammeneinstellung:

The Y9529 valve includes a pilot flame adjustment screw. This screw allows for fine-tuning the pilot flame size. A proper pilot flame should be blue, steady, and envelop the tip of the thermocouple/thermopile. Adjust clockwise to decrease flame, counter-clockwise to increase. Do not adjust to an excessively large or small flame.

6. Wartung

Regular maintenance ensures the longevity and safe operation of your Star Y9529 Safety Pilot Valve. All maintenance should be performed by a qualified service technician.

7. Fehlerbehebung

Before attempting any troubleshooting, ensure the gas supply is on and that you have followed the lighting instructions correctly. If you are unsure or uncomfortable performing these checks, contact a qualified service technician.

ProblemMögliche UrsacheLösung
Pilot leuchtet nicht.No gas supply; clogged pilot orifice; faulty thermocouple/thermopile; air in gas line.Ensure gas supply is on. Clean pilot orifice (professional). Replace thermocouple/thermopile. Purge air from line (professional).
Pilot lights but goes out when button is released.Thermocouple/thermopile not heating sufficiently; faulty thermocouple/thermopile; pilot flame too small or misdirected.Hold pilot button longer. Check thermocouple/thermopile position in flame. Adjust pilot flame. Replace thermocouple/thermopile.
Main burner does not light after pilot is lit.Main gas valve not open; faulty gas control valve; obstruction in main burner.Ensure main gas valve is "ON". Contact professional for valve or burner inspection.
Gasgeruch.Gas-Leck.Immediately turn off gas supply. Open windows and doors. Do not operate electrical switches. Contact gas company or qualified technician.

8. Spezifikationen

SpezifikationWert
ModellnummerY9529 / 52-1071
MarkeStar (Mfg: Baso, Mfg# H19AL-2)
Kompatibilität mit verschiedenen GastypenNatural Gas (NAT) / Liquid Propane (LP)
Main Gas Connection3/8" FPT (Innengewinde)
Pilot Gas Connection1/4" CCT (Copper Capillary Tube) Pilot Out
BTU-Bewertung140,000 BTU
MerkmaleManual Pilot Safety, Pilot Flame Adjustment
Artikelgewicht1.23 Pfund
Abmessungen (ungefähr)Width 2-1/2"
Erstes verfügbares Datum1. Oktober 2016

9. Garantie und Support

Specific warranty information for the Star Y9529 Safety Pilot Valve should be obtained directly from the manufacturer, Star Manufacturing, or the authorized seller from whom the product was purchased. Warranty terms typically cover defects in materials and workmanship for a specified period.

For technical support, service, or to inquire about replacement parts, please contact your equipment supplier or a qualified service technician specializing in commercial gas appliances. Always provide the model number (Y9529 or 52-1071) and any relevant serial numbers when seeking support.

Zugehörige Dokumente - Y9529 / 52-1071

Vorview STAR Capella 2HCX Lifted Parts Manual - Umfassende Komponentenübersicht
Detaillierte Teileliste für das STAR Capella 2HCX Nutzfahrzeug mit Höherlegung. Hier finden Sie Teilenummern, Beschreibungen und Spezifikationen aller Komponenten, übersichtlich nach Systemen geordnet.
Vorview Star Zweiseitige Grills der Serien GX10, GX14 und GX20: Installations- und Bedienungsanleitung
Ausführliche Installations-, Betriebs-, Wartungs- und Sicherheitshinweise für die Star-Zweiseitengrills der Serien GX10, GX14 und GX20. Enthält elektrische Spezifikationen, Hinweise zur Fehlerbehebung und Garantieinformationen.
Vorview Die App und die App von KAoA-STAR sind Teil des Programms
KAoA-STAR hat sich vor einigen Jahren für ein Jahr entschieden Die meisten Menschen sind nicht in der Lage, die Welt zu erobern Es ist nicht einfach, dies zu tun.
Vorview Anleitung zum Zusammenklappen des aufblasbaren Kajaks STAR Paragon
Schritt-für-Schritt-Anleitung zum richtigen Falten und Aufbewahren Ihres aufblasbaren Kajaks STAR Paragon für einfachen Transport und Lagerung.
Vorview MotagAnleitung für Star Waschbeckenunterschrank X9T Q5 705
Detaillierte Montageanleitung für den Star Waschbeckenunterschrank, Modell X9T Q5 705. Enthält Schritt-für-Schritt-Anweisungen, Teileliste und wichtige Sicherheitshinweise für eine erfolgreiche Installation.
Vorview Star mC-Print3 – Kurzanleitung zur Einrichtung: Verbindung mit Geräten
Diese Anleitung bietet eine Schritt-für-Schritt-Anleitung zur Einrichtung des Star mC-Print3-Druckers. Sie umfasst die Überprüfung des mitgelieferten Zubehörs, das Herunterladen des mC-Print3-Dienstprogramms und die Verbindung des Druckers mit iOS-, Android-, Mac-, Linux- und Windows-Geräten via Bluetooth, USB oder LAN-Kabel. Außerdem enthält sie Tipps zur Fehlerbehebung und eine Anleitung zur Montage der Rückabdeckung.