Gentex GN-503 Kombinierter Rauch- und Kohlenmonoxidmelder – Benutzerhandbuch

Model: GN-503 | Brand: Gentex

1. Einleitung

The Gentex GN-503 Series combination photoelectric smoke and electrochemical carbon monoxide alarms are designed for use in all dwelling units, including homes, apartments, hospitals, nursing homes, hotels, and motels. These devices serve as an essential evacuation tool, complying with ANSI/UL 217, ANSI/UL 2034, applicable IBC/IFC/IRC Standards, NFPA 72, and NFPA 720. This manual provides detailed instructions for the proper installation, operation, and maintenance of your GN-503 alarm to ensure optimal performance and safety.

2. Sicherheitshinweise

3. Produktüberschreitungview

The Gentex GN-503 is a dual-sensor alarm designed to detect both smoke and carbon monoxide. Key components and indicators are detailed below.

Two Gentex GN-503 combination smoke and carbon monoxide alarms with a 9V battery.

This image displays two Gentex GN-503 combination smoke and carbon monoxide alarms. Each alarm is round and white, featuring a speaker grille, indicator lights for smoke, carbon monoxide, and power, and a push-to-test/reset button. Text on the alarm indicates 'Smoke and Carbon Monoxide Alarm', 'DO NOT PAINT', and instructions for twisting to install or remove. A 9V Duracell battery is shown in the foreground, ready for installation.

Hauptmerkmale:

4. Einrichtung und Installation

Follow these steps for proper installation of your Gentex GN-503 alarm.

  1. Unpack the Alarm: Carefully remove the alarm and the included 9V battery from its packaging.
  2. Einlegen der Batterie: Open the battery compartment and connect the 9V battery to the battery clip. Ensure proper polarity. The alarm may chirp briefly to indicate battery connection. Close the battery compartment securely.
  3. Montageort: Choose a suitable location for the alarm. For smoke detection, install on every level of your home, inside bedrooms, and outside sleeping areas. For carbon monoxide detection, install near sleeping areas and on every level of the home. Avoid installing near combustion appliances, in garages, or in extremely dusty, dirty, or humid areas.
  4. Verdrahtung: The GN-503 operates on 120VAC. Connect the quick disconnect wiring harness to the appropriate household wiring according to local electrical codes. Ensure power is off at the circuit breaker before wiring.
  5. Montage: The mounting hardware adapts to standard junction boxes. Secure the mounting bracket to the junction box or ceiling/wall using the provided screws. Once the wiring harness is connected to the alarm, align the alarm with the mounting bracket and twist clockwise to secure it in place. The alarm should click into position.
  6. Strom wiederherstellen: Turn on the power at the circuit breaker. The alarm should power on and may perform a brief self-test.

5. Bedienungsanleitung

Understanding the alarm's indicators and test functions is crucial for its effective operation.

Alarmanzeigen:

Alarm Sounding Patterns:

Testen des Alarms:

Es wird empfohlen, Hold To Test Weekly.

  1. Selbsttest: Press and hold the 'Push To Reset' button for a few seconds. The alarm will perform a self-test, sounding both the smoke and CO alarm patterns. Release the button once the test begins.
  2. Funktionstest: This test verifies the sensor's functionality. Follow the self-test procedure. If the alarm sounds correctly, it is functioning properly.

The alarm is non-latching, meaning it will automatically reset once the smoke or carbon monoxide clears from the sensor.

6. Wartung

Regular maintenance ensures the longevity and reliability of your GN-503 alarm.

7. Fehlerbehebung

If your Gentex GN-503 alarm is not functioning as expected, refer to the following common issues and solutions:

ProblemMögliche UrsacheLösung
Der Alarm ertönt alle 30–60 SekundenLow or missing 9V battery.Replace the 9V battery immediately. Ensure proper polarity.
Alarm sounds intermittently or falselyDust or debris in the sensor chamber; high humidity; cooking fumes; steam.Clean the alarm regularly. Ventilate the area. Press the 'Push To Reset' button to clear the alarm. Relocate the alarm if false alarms persist due to environmental factors.
CO alarm sounds, but no visible CO sourcePresence of carbon monoxide; sensor malfunction.Evacuate the premises immediately and call emergency services. Do not re-enter until the area is deemed safe. If false alarm, ensure proper ventilation and test the unit.
Alarm provides an 'end of life' signalCO sensor has reached its operational limit.The alarm unit needs to be replaced. Purchase a new Gentex GN-503 alarm.
Alarm does not power onNo AC power; battery not installed or dead; wiring issue.Check circuit breaker. Ensure 9V battery is correctly installed and charged. Verify wiring connections. Consult a qualified electrician if necessary.

8. Spezifikationen

Technical specifications for the Gentex GN-503 Combination Smoke and Carbon Monoxide Alarm:

SpezifikationDetail
HerstellerGENTEX
TeilenummerGN-503
Technische Daten15.88 x 4.57 x 15.88 cm
Stromquelle120VAC with 9V Battery Back-up
Artikelpaket Menge1
SensortypPhotoelektrisch (Rauch), elektrochemisch (CO)
Hupenfrequenz3100 Hz
Smoke Annunciation PatternZeitlich 3
CO Annunciation PatternZeitlich 4
ASINB005Y6I778
UPC808226784847
Datum der ersten Verfügbarkeit24. Januar 2022

9. Garantie und Support

For warranty information, technical support, or service inquiries regarding your Gentex GN-503 alarm, please contact Gentex customer service directly. Refer to the product packaging or the Gentex official webAuf dieser Website finden Sie die aktuellsten Kontaktdaten und Garantiebedingungen.

Zugehörige Dokumente - GN-503

Vorview Installations-, Betriebs- und Garantiehandbuch für den Gentex Full Display Mirror
Umfassende Anleitung zur Installation, Bedienung und Fehlerbehebung des Gentex Full Display Mirror (FDM). Enthält detaillierte Schritte, Funktionserklärungen und eine 36-monatige eingeschränkte Garantie der Voxx Electronics Corporation.
Vorview Gentex 8000 Serie Fotoelektrischer Rauchmelder Installations- und Bedienungsanleitung
Installationsanleitung und Besitzerinformationen für Gentex 8000 Serie fotoelektrische Rauchmelder für offene Bereiche. Umfasst die Modelle 8240, 8243, 8100 und 8103, Spezifikationen, Bedienung, Platzierungsrichtlinien gemäß NFPA 72, Installation, Wartung und Garantie.
Vorview Gentex-Einbauanleitung für automatisch abblendende Spiegel mit Kompass und Temperaturanzeige
Ausführliche Installationsanleitung für den Gentex-Automatikspiegel mit Kompass und Temperaturanzeige (Modell ADVGEN20A) von VOXX Corporation. Diese Anleitung umfasst den Lieferumfang, die benötigten Werkzeuge, eine detaillierte Schritt-für-Schritt-Installation, die Verkabelung, die Funktionsprüfung, die Kompassjustierung, die Temperaturfunktionen und die Fehlerbehebung.
Vorview Gentex 8000/8003 Serie Fotoelektrische Rauchmelder – Spezifikationen und Anwendungsbereiche
Detaillierte Informationen zu den fotoelektrischen Rauchmeldern der Serien Gentex 8000/8003, einschließlich Anwendungsbereiche, Standardfunktionen, Produktlisten, Konformität, elektrische Spezifikationen und Schaltpläne. Geeignet für den Einsatz in Gewerbe, Industrie, Wohngebäuden und öffentlichen Einrichtungen.
Vorview Gentex Spiegel-Montageanleitung: Ein umfassender Leitfaden
Detaillierte Installationsanleitung für Gentex-Rückleuchten mit automatischer Dimmfunktion, Kompass-/Temperaturanzeige und Kartenleuchteview Spiegel mit dem universellen Kabelbaum von MITO CORPORATION. Inklusive Teileliste, benötigtem Werkzeug und schrittweiser Anleitung für Verkabelung und Montage.
Vorview Gentex 7139CS & 7139LS Rauchmelder: Installations- und Benutzerhandbuch
Umfassende Anleitung zur Installation und Bedienung der fotoelektrischen Rauchmelder Gentex 7139CS und 7139LS. Enthält Sicherheitsinformationen, Informationen zur Verkabelung, Montage, Wartung und Fehlerbehebung für den gewerblichen und privaten Gebrauch.