AEMC 2970.12

AEMC 2970.12 Fuse Set Instruction Manual

For 3-Point Ground Resistance Testers

Einführung

This manual provides essential information for the proper use and maintenance of the AEMC 2970.12 Fuse Set. This set contains five replacement fuses specifically designed for use with AEMC ground resistance tester models 3620, 3640, 4600, and 4610. Understanding these instructions will ensure safe and effective operation of your testing equipment.

Five AEMC 2970.12 fuses, clear glass tubes with silver end caps, arranged vertically.

Abbildung 1: AEMC 2970.12 Fuse Set. This image displays five individual fuses, each featuring a clear glass body that allows visibility of the internal filament, and metallic end caps. These fuses are designed for specific electrical protection in compatible AEMC ground resistance testers.

Setup und Installation

The AEMC 2970.12 fuses are critical components for protecting your ground resistance tester. Always ensure the tester is powered off and disconnected from any power source before attempting fuse replacement.

  1. Identify the Fuse Compartment: Refer to your specific AEMC ground resistance tester's manual (models 3620, 3640, 4600, or 4610) to locate the fuse compartment. This is typically accessible via a screw-on cap or a small panel.
  2. Alte Sicherung entfernen: Carefully unscrew or unclip the fuse holder. Gently remove the blown or faulty fuse. Note the orientation if applicable, though these cylindrical fuses are generally non-polar.
  3. Verify Fuse Specifications: Before installing, confirm that the replacement fuse is an AEMC 2970.12, rated at 0.1 Amps and >250V (fast blow), with dimensions of 6 x 32mm. Using an incorrect fuse type can damage the instrument or compromise safety.
  4. Install the New Fuse: Insert the new AEMC 2970.12 fuse into the fuse holder. Ensure it is seated firmly and correctly.
  5. Sichern Sie das Fach: Replace the fuse compartment cover or screw on the cap securely.
  6. Testfunktionalität: After replacement, power on the ground resistance tester and perform a basic function check as outlined in your tester's operating manual to ensure proper operation.

Warnung: Always use fuses with the correct current and voltage ratings. Using an improperly rated fuse can lead to equipment damage, fire, or personal injury. If unsure, consult a qualified technician.

Überlegungen zum Betrieb

The AEMC 2970.12 fuses are passive components that protect your ground resistance tester from overcurrent conditions. Their operation is integral to the safety and longevity of the instrument. No direct user interaction is required during normal operation once installed.

Wartung

Proper storage and occasional inspection can help ensure the reliability of your spare AEMC 2970.12 fuses.

Fehlerbehebung

If your AEMC ground resistance tester is not powering on or functioning correctly, a blown fuse is a common cause. This section outlines basic troubleshooting steps related to the fuse.

Technische Daten

Key specifications for the AEMC 2970.12 Fuse Set:

Attribut Wert
Modellnummer 2970.12
Marke AEMC
Aktuelle Bewertung 0.1 Amps
Bandtage Bewertung >250 Volts
Sicherungstyp Fast Blow
Fuse Size (W x H) 6 x 32 mm
Packungsmenge 5 Sicherungen
Kompatibilität AEMC Ground Resistance Testers (Models 3620, 3640, 4600, 4610)

Garantie und Support

For specific warranty information regarding the AEMC 2970.12 Fuse Set or the compatible AEMC ground resistance testers, please refer to the documentation provided with your original product purchase or visit the official AEMC Instruments website. AEMC Instruments manufactures electrical testing and measurement instruments and is headquartered in Foxborough, MA.

For technical support, service, or inquiries about replacement parts, please contact AEMC Instruments directly through their official channels.

Zugehörige Dokumente - 2970.12

Vorview AEMC 2620 Fehlerstrom-/Leckstromdetektor mit künstlichem Neutralleiter AN-1 – Benutzerhandbuch
Benutzerhandbuch für den AEMC Fehlerstrom-/Leckagedetektor Modell 2620 und das Zubehör AN-1 Künstlicher Neutralleiter mit detaillierten Angaben zu Spezifikationen, Bedienung, Fehlersuche und Wartung.
Vorview AEMC PEL 52 Power & Energy Logger User Manual
User manual for the AEMC PEL 52 Power & Energy Logger, detailing its features, setup, operation, specifications, and maintenance for accurate electrical measurements.
Vorview AEMC PEL 52 Power & Energy Logger User Manual
User manual for the AEMC PEL 52 Power & Energy Logger, detailing its features, specifications, operation, setup, maintenance, and troubleshooting for electrical measurements in single-phase and two-phase distribution networks.
Vorview So ersetzen Sie die Batterie in den Leistungs- und Energieloggern AEMC PEL 102 und PEL 103
Schritt-für-Schritt-Anleitung zum sicheren Austausch des 8.4-V-NiHM-Akkupacks in den Leistungs- und Energielogger-Instrumenten AEMC PEL 102 und PEL 103. Enthält die erforderlichen Werkzeuge, Vorsichtsmaßnahmen und visuelle Beschreibungen.
Vorview AEMC OXIII SERIES Tragbare Oszilloskope Benutzerhandbuch
Dieses Benutzerhandbuch bietet umfassende Informationen zu den tragbaren Oszilloskopen der AEMC OXIII-Serie, einschließlich der Modelle OX 7102, OX 7104, OX 7202 und OX 7204. Erfahren Sie mehr über deren Funktionen, Bedienung und Wartung für präzise elektrische Messungen.
Vorview AEMC Digital FlexProbe 400D/4000D Serie – Benutzerhandbuch – Wechselstrommessung
Benutzerhandbuch für die AEMC Digital FlexProbe Modelle 400D-6, 400D-10, 4000D-14 und 4000D-24. Zu den Merkmalen gehören TRMS-Wechselstrommessung, CAT IV-Klassifizierung, flexibler Sensorbetrieb und detaillierte Spezifikationen für elektrische, umweltbedingte und mechanische Parameter.