Linear 212LS-C26DCR-RT

Linear 212LS-C26DCR-RT Elektronisches Zutrittskontroll-Zylinderschloss – Benutzerhandbuch

Model: 212LS-C26DCR-RT

1. Einleitung

This manual provides instructions for the installation, operation, and maintenance of the Linear 212LS-C26DCR-RT Electronic Access Control Cylindrical Lockset. This lockset is designed for secure access control in both commercial and residential environments.

Hauptmerkmale:

  • Durable construction for extended lifespan.
  • Clutch lever design for enhanced security.
  • Long battery life (up to 15,000 keypad activations) with low-battery alert.
  • Password retention during battery removal.
  • Easy installation into standard cylindrical door preps (ANSI 151.8).
  • Master password control system for managing up to 120 user passwords.
  • Mechanical key override for emergency situations.

2. Sicherheitshinweise

Please read all instructions carefully before installation and operation. Failure to follow these instructions may result in damage to the product, property, or personal injury.

  • Ensure proper battery polarity when installing batteries.
  • Do not expose the lockset to extreme temperatures or moisture beyond its intended operating conditions.
  • Keep mechanical keys in a secure location, separate from the lockset.
  • Do not attempt to disassemble or repair the lockset yourself. Refer to qualified personnel for service.

3. Packungsinhalt

Vergewissern Sie sich vor Beginn der Installation, dass alle Teile vorhanden sind:

  • Linear 212LS-C26DCR-RT Electronic Access Control Cylindrical Lockset
  • Montagezubehör
  • 2 Mechanical keys
  • Benutzerhandbuch (dieses Dokument)

Note: Four AA 1.5 volt batteries are required and are not included in the package.

4. Installation

The lockset is designed for easy installation into a standard cylindrical door preparation (ANSI 151.8).

4.1. Bereiten Sie die Tür vor

Ensure your door has a standard cylindrical door prep. If not, consult a professional for proper door preparation.

4.2. Install the Lockset

  1. Follow the detailed instructions provided with the mounting hardware to secure the lockset components to the door.
  2. Ensure all cables are properly connected and routed to avoid pinching.

4.3. Batterien einlegen

  1. Locate the battery compartment, typically on the interior side of the lockset.
  2. Insert four (4) AA 1.5 volt batteries, ensuring correct polarity.
  3. Schließen Sie den Batteriefachdeckel fest.

Linear 212LS-C26DCR-RT Electronic Access Control Cylindrical Lockset, Right Hand OpeningFigure 1: Linear 212LS-C26DCR-RT Lockset showing keypad and lever handle.

5. Bedienung

The lockset operates using a keypad for electronic access or mechanical keys for override.

5.1. Initial Setup and Master Password

Upon initial power-up, you will need to set a master password. Refer to the specific programming instructions included with your lockset for this procedure. The master password allows for the management of up to 120 individual user passwords.

5.2. Adding User Passwords

Using the master password, you can add or delete up to 120 unique user passwords. Each user password grants access through the keypad.

5.3. Tastatureingabe

  1. Enter a valid user password on the keypad.
  2. The lock will disengage, allowing the handle to operate.
  3. If an incorrect code is entered, the handle will not mechanically engage the cylinder, preventing unauthorized entry.

5.4. Mechanical Key Override

In emergency situations or if batteries are depleted, the provided mechanical keys can be used to unlock the door. Insert the key into the keyway and turn to unlock.

6. Wartung

6.1. Batteriewechsel

The lockset is designed for approximately 15,000 keypad activations, which translates to about 5 years of usage based on 10 activations per day. A low-battery alert will indicate when batteries need replacement. Replace all four AA batteries simultaneously with new, high-quality alkaline batteries.

6.2. Reinigung

Clean the lockset exterior with a soft, damp cloth. Avoid abrasive cleaners or solvents that may damage the finish or electronic components.

7. Fehlerbehebung

ProblemMögliche UrsacheLösung
Handle does not engage after entering correct code.Low batteries or mechanical issue.Replace batteries. If problem persists, use mechanical key and contact support.
Die Tastatur reagiert nicht.Dead batteries or internal electronic fault.Replace batteries. If still unresponsive, use mechanical key and contact support.
Cannot add or delete user passwords.Incorrect master password or programming error.Verify master password. Refer to programming instructions for correct procedure.

8. Spezifikationen

BesonderheitDetail
Modellnummer212LS-C26DCR-RT
Abmessungen (L x B x H)10.1 x 8.5 x 7.4 Zoll
Gewicht5.5 Pfund
Stromquelle4 AA 1.5V Batterien (nicht im Lieferumfang enthalten)
AkkulaufzeitApprox. 15,000 activations
SperrtypTastenfeld
BesonderheitWasserfest
MaterialMetall

9. Garantie und Support

This product typically comes with a manufacturer's warranty. Please refer to the warranty card included with your purchase for specific terms and conditions. For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact Linear customer service. Contact information can usually be found on the manufacturer's webauf der Website oder auf der Produktverpackung.

Note: The warranty period for this product is generally 24 months, primarily for wholesale purchasers. Please confirm your specific warranty coverage.

Zugehörige Dokumente - 212LS-C26DCR-RT

Vorview Linear AK-11 Digital Keyless Entry System Installation and Programming Manual
The Linear AK-11 is a robust digital keyless entry system designed for access control applications. It features a durable cast aluminum enclosure, supports up to 480 programmable entry codes (1-6 digits), and offers multiple output options including two relays and two solid-state outputs. This system is ideal for controlling access to doors and gates, providing features like anti-passback, keypad lockout, and various input functionalities for enhanced security and convenience.
Vorview Installations- und Programmieranleitung für das digitale schlüssellose Zugangssystem Linear AK-11
Ausführlicher Leitfaden für die Installation und Programmierung des digitalen schlüssellosen Zugangssystems Linear AK-11, der Funktionen, Spezifikationen, Verkabelung, Einrichtung, Bedienung und Fehlerbehebung abdeckt.
Vorview Installationshandbuch für die Linear Entry Pro-Serie: Hardware- und Systemeinrichtung
Dieses Handbuch bietet umfassende Installations-, Verdrahtungs- und Konfigurationshinweise für die Telefon-Türsprechanlagen und Zutrittskontrollsysteme der Linear Entry Pro-Serie (EP-4xx, EP-7xx). Es beschreibt detailliert die Hardwaremerkmale, die Positionen der Komponenten, die Systemdiagnose, die Fehlerbehebung und die Spezifikationen für ein sicheres Zutrittsmanagement.
Vorview Linear AccessKey AK-1 Digital Keypad Entry System - Technical Specifications and Features
Detailed information on the Linear AccessKey AK-1, a digital keypad entry system for commercial access control, featuring rugged design, multiple outputs, and programmable PIN codes.
Vorview Linear Wireless Entry Systems: Keypads and Controllers
Explore Linear's range of wireless entry systems, including MDKP keypads, AP-5 controllers, and various AK-series keypads for secure access control in residential, commercial, and industrial applications.
Vorview Linear AM/II Drahtloses Zutrittskontrollsystem: Installations- und Programmierhandbuch
Ausführliche Installations- und Programmieranleitung für das drahtlose Zutrittskontrollsystem Linear AM/II mit Informationen zu Funktionen, Einrichtung und Bedienung. Erfahren Sie mehr über die drahtlosen Funktionen, die Wiegand-/RS-232-Schnittstellen und die Netzwerkoptionen.