The Wilo ECC29-15.50 Submersible Sump Pump is designed for efficient water removal in residential and light commercial applications. It features robust construction and reliable components to ensure long-lasting performance.
Key features include: Cast iron housing and volute, Thermoplastic Vortex Impeller, Stainless Steel bottom screened inlet, Replaceable tether float switch, Permanent split capacitor motor with thermal overload protection, 1.5-inch NPT discharge (1.25-inch adapter included), and a 10-ft power cord.

Image: Wilo ECC29-15.50 Submersible Sump Pump, showing its cast iron body, float switch, and discharge port.
Technische Daten
| Attribut | Detail |
|---|---|
| Marke | Wilo |
| Modellnummer | 2708304 (ECC29-15.50) |
| Bandtage | 115 Volt |
| PS | 0.50 PS |
| Material | Gusseisen, Edelstahl |
| Artikelgewicht | 22 Pfund |
| Technische Daten | 9 x 6 x 11.4 Zoll |
| Stromquelle | Kabelgebundene Elektrik |
| Entladungsgröße | 1.5-inch NPT (1.25-inch adapter included) |
| Merkmale | Thermal overload protection, Stainless Steel bottom screened inlet, Replaceable tether float switch |
Aufstellen
Proper installation is crucial for the safe and efficient operation of your sump pump. Always ensure power is disconnected before handling the pump.
- Sicherheit geht vor: Ensure the power supply to the sump pit area is turned off at the circuit breaker before beginning any installation work.
- Vorbereitung der Sumpfgrube: Ensure the sump pit is clean and free of debris. The pit should be large enough to accommodate the pump and allow for proper float switch operation.
- Platzierung der Pumpe: Place the pump on a solid, level surface at the bottom of the sump pit. Avoid placing it directly on dirt or gravel, which can lead to clogging. Use a brick or concrete block if necessary.
- Anschluss des Abflussrohrs: Connect a rigid PVC pipe (recommended) to the pump's 1.5-inch NPT discharge port. Use the included 1.25-inch adapter if your existing plumbing requires it. Install a check valve in the discharge line above the pump to prevent water from flowing back into the pit when the pump shuts off.
- Einstellung des Schwimmerschalters: Position the tether float switch so it can move freely without obstruction. Ensure it activates the pump at the desired water level and allows the pump to run long enough to adequately drain the pit before deactivating. Avoid contact with the pit walls or other pipes.
- Stromanschluss: Plug the pump's 10-ft power cord into a properly grounded 115-volt GFCI (Ground Fault Circuit Interrupter) outlet. Do not use extension cords.
- Testbetrieb: Once installed, fill the sump pit with water to verify the pump activates and deactivates correctly. Check for any leaks in the discharge line.
Betrieb
The Wilo ECC29-15.50 sump pump operates automatically via its tether float switch. When the water level in the sump pit rises and lifts the float switch to its activation point, the pump will turn on and begin to discharge water.
- Automatische Operation: The pump is designed for continuous automatic operation. It will activate when the water level reaches the set point of the float switch and will continue to pump until the water level drops and the float switch deactivates the pump.
- Erstinbetriebnahme: After installation, ensure the pump is plugged into a GFCI outlet. Manually lift the float switch to ensure the pump turns on. Allow it to run for a short period, then release the float to ensure it turns off.
- Überwachung: Periodically check the sump pit, especially during heavy rain, to ensure the pump is operating as expected. Listen for unusual noises or vibrations, which could indicate an issue.
- Thermischer Überlastschutz: The pump is equipped with thermal overload protection. If the motor overheats, it will automatically shut off to prevent damage. The pump will restart once it has cooled down. Identify and resolve the cause of overheating if this occurs frequently.
Wartung
Regular maintenance helps ensure the longevity and reliable performance of your sump pump. Always disconnect power before performing any maintenance.
- Monthly Checks (or more frequently during heavy use):
- Reinigung der Sumpfgrube: Remove any debris, dirt, or sediment from the bottom of the sump pit that could clog the pump's inlet screen or impede float switch operation.
- Schwimmerschalter prüfen: Manually lift the float switch to ensure it moves freely and activates/deactivates the pump. Ensure no wires or debris are interfering with its movement.
- Inspect Inlet Screen: Check the stainless steel bottom screened inlet for any blockages and clean if necessary.
- Netzkabel prüfen: Inspect the power cord for any signs of damage, fraying, or wear.
- Jährliche Inspektion:
- Pumpe ausbauen: If possible, remove the pump from the pit for a more thorough inspection.
- Laufrad reinigen: Inspect the thermoplastic vortex impeller for any debris or buildup and clean carefully.
- Check Check Valve: Ensure the check valve in the discharge line is functioning correctly and not stuck open or closed.
- Winterization (if applicable in freezing climates): If the pump is in an unheated area and there's a risk of freezing, ensure the discharge line is sloped to drain completely or is disconnected and drained to prevent ice buildup.
Fehlerbehebung
Before attempting any troubleshooting, always disconnect the pump from the power source. If you are unsure about any step, consult a qualified electrician or plumber.
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Pumpe läuft nicht. | No power; tripped GFCI; float switch stuck or defective; motor overheated. | Check power supply and GFCI. Ensure float switch moves freely. Allow motor to cool if overheated. Replace float switch if defective. |
| Pumpe läuft dauernd. | Float switch stuck in "on" position; check valve faulty; continuous water inflow. | Clear obstructions around float switch. Inspect/replace check valve. Investigate source of continuous water inflow. |
| Pump runs but does not remove water. | Clogged inlet screen or impeller; air lock; discharge pipe blocked or frozen; pump not submerged. | Clean inlet screen and impeller. Clear air lock by tilting pump. Check discharge pipe for blockages. Ensure pump is fully submerged. |
| Die Pumpe ist laut oder vibriert übermäßig. | Debris in impeller; pump not sitting level; worn bearings (less common for new pump). | Clean impeller. Ensure pump is on a stable, level surface. If noise persists, professional service may be required. |