1. Einleitung
The TROTEC TA300 is a professional hot-wire anemometer designed for precise measurement of air velocity, air temperature, and volumetric flow. Its practical telescopic probe allows for versatile applications, including measurements in ducts and hard-to-reach areas. This instrument combines a robust thermal wire sensor with advanced microprocessor technology to ensure fast and accurate results.
This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your TA300 anemometer. Please read it thoroughly before using the device.

Image 1: TROTEC TA300 Anemometer main unit and telescopic probe. The display shows 'VEL 3.11 m/s' and 'TEMP 22.2 °C'.
2. Sicherheitshinweise
Beachten Sie stets die folgenden Sicherheitsvorkehrungen, um Verletzungen und Schäden am Gerät zu vermeiden:
- Lesen Sie vor der Inbetriebnahme das gesamte Handbuch.
- Das Gerät darf nicht in explosionsgefährdeten Bereichen oder in der Nähe von brennbaren Materialien betrieben werden.
- Setzen Sie das Gerät keinen extremen Temperaturen, direkter Sonneneinstrahlung oder hoher Luftfeuchtigkeit aus.
- Versuchen Sie nicht, das Gerät zu verändern oder zu zerlegen. Reparaturen dürfen nur von autorisiertem Personal durchgeführt werden.
- Bewahren Sie das Gerät außerhalb der Reichweite von Kindern auf.
- Ensure the telescopic probe is handled with care to prevent bending or damage to the sensor.
3. Packungsinhalt
Prüfen Sie beim Auspacken, ob alle Artikel vorhanden und unbeschädigt sind:
- TROTEC TA300 Anemometer
- Telescopic hot-wire probe
- Kalibrierungszertifikat
- Benutzerhandbuch (dieses Dokument)
- Carrying case (if included with your model)
4. Produktmerkmale
The TROTEC TA300 Anemometer offers the following key features:
- Präzise Messung: Accurately determines air velocity, air temperature, and volumetric flow.
- Telescopic Probe: Extendable up to 1 meter for measurements in ducts and hard-to-reach locations.
- Robust Sensor: Equipped with a durable thermal wire sensor.
- Fortschrittlicher Mikroprozessor: Ensures fast and precise signal processing.
- LCD-Display mit Hintergrundbeleuchtung: Easy readability even in poorly lit environments.
- Datenhaltefunktion: Friert den aktuellen Messwert auf dem Display ein.
- Min/Max Value Indication: Zeigt die minimalen und maximalen aufgezeichneten Werte an.
- Berechnung des Mittelwerts: Calculates spot and time-averaged values.
- Volumetric Flow Area Input: Easily specify the cross-sectional area for volumetric flow calculations.
- Automatisches Ausschalten: Verlängert die Batterielebensdauer.
- Kalibrierungszertifikat: Included as standard for professional assurance.

Abbildung 2: Detailansicht view of the TA300 control buttons and LCD display.
5. Einrichtung
5.1. Einlegen der Batterie
The TA300 anemometer typically uses a 9V block battery. To install or replace the battery:
- Suchen Sie die Abdeckung des Batteriefachs auf der Rückseite des Geräts.
- Open the cover by sliding or unscrewing it (refer to the diagram if available).
- Setzen Sie eine neue 9V-Batterie ein und achten Sie dabei auf die richtige Polarität.
- Schließen Sie den Batteriefachdeckel fest.

Bild 3: Draufsicht view of the TA300, illustrating the main unit and probe connection area.
5.2. Attaching the Probe
The telescopic hot-wire probe connects to the main unit via a cable.
- Carefully insert the probe's connector into the designated port on the main unit.
- Ensure the connection is firm to prevent signal loss during measurement.
5.3. Erstes Einschalten
Drücke den Power Knopf (⑂) to turn on the device. The display will illuminate, and the device will perform a self-test before showing measurement readings.
6. Bedienungsanleitung
6.1. Extending the Telescopic Probe
The probe can be extended up to 1 meter for reaching measurement points.
- Gently pull the probe tip to extend it to the desired length.
- Vermeiden Sie übermäßige Kraftanwendung, um Schäden zu vermeiden.
- Ensure the probe is fully retracted when not in use to protect the sensor.

Image 4: Extended telescopic probe tip with hot-wire sensor.
6.2. Messmodi
The TA300 can measure air velocity, temperature, and volumetric flow.
- Air Velocity (VEL): The primary measurement displayed in m/s, ft/min, km/h, or mph.
- Temperatur (TEMP): Measured simultaneously with air velocity, displayed in °C or °F.
- Volumetric Flow (FLOW): Calculated based on air velocity and a user-defined cross-sectional area.
6.3. Einheiten ändern
Drücken Sie die "Einheit" button to cycle through available measurement units for velocity and temperature.
6.4. Setting Volumetric Flow Area
To measure volumetric flow, you must input the cross-sectional area of the duct or opening:
- Drücken Sie die "FLOW/TEMP" button to switch to volumetric flow mode.
- Verwenden Sie die "AUFSTELLEN" button to enter the area setting menu.
- Adjust the area value using the arrow buttons and confirm with "Eingeben".
6.5. Using Hold, Min/Max, and Mean Functions
- Halten: Drücken Sie "HALTEN/NULL" to freeze the current display reading. Press again to release.
- Minimal Maximal: Drücken Sie "MAX/MIN" Zu view the minimum or maximum recorded values during a measurement session.
- Bedeuten: Drücken Sie "BEDEUTEN" to calculate and display the average value over a period or series of spot measurements.
7. Wartung
7.1. Reinigung
Halten Sie das Gerät sauber, um eine optimale Leistung zu gewährleisten.
- Wischen Sie das Hauptgerät mit einem weichen, damp Tuch. Keine Scheuer- oder Lösungsmittel verwenden.
- The hot-wire sensor on the probe is delicate. Clean it only with a soft brush or compressed air, if absolutely necessary, and with extreme care. Avoid touching the sensor directly.
7.2. Speicherung
When not in use, store the TA300 in its protective carrying case in a dry, dust-free environment, away from extreme temperatures.
- Ensure the telescopic probe is fully retracted before storage.
- Um ein Auslaufen zu verhindern, sollte die Batterie entfernt werden, wenn das Gerät längere Zeit nicht benutzt wird.
7.3. Kalibrierung
The TA300 comes with a factory calibration certificate. For continued accuracy, periodic recalibration by an authorized service center is recommended, especially for professional applications.
8. Fehlerbehebung
If you encounter issues with your TROTEC TA300, refer to the following table:
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Gerät lässt sich nicht einschalten. | Batterie defekt oder falsch eingebaut. | Prüfen Sie die Batteriepolarität oder ersetzen Sie die Batterie durch eine neue 9V-Batterie. |
| Ungenaue Messwerte. | Dirty or damaged sensor; device needs recalibration. | Gently clean the sensor (see Maintenance); consider professional recalibration. |
| Display shows "Err" or unusual characters. | Internal error or sensor malfunction. | Turn off the device, remove the battery, wait 30 seconds, then reinsert and restart. If the problem persists, contact customer support. |
| Probe connection issues. | Loose or damaged probe cable/connector. | Ensure the probe connector is securely inserted. Inspect the cable for visible damage. |
Sollte das Problem nach Anwendung dieser Lösungsansätze weiterhin bestehen, wenden Sie sich bitte an den TROTEC-Kundendienst.
9. Spezifikationen
Technical data for the TROTEC TA300 Anemometer:
| Modellnummer | 3510004005 |
| Hersteller | TROTEC |
| Abmessungen (L x B x H) | 21 x 7.5 x 5 cm |
| Gewicht | 1.89 kg |
| Probe Length (extended) | Bis zu 1 Meter |
| Stromquelle | 9V-Batterie (nicht im Lieferumfang enthalten) |
| Farbe | Schwarz / Gelb |
| Material | Metall |
| Im Lieferumfang enthaltene Komponenten | Anemometer TA300, Calibration Certificate |
10. Garantie und Support
10.1. Garantieinformationen
The TROTEC TA300 Anemometer is covered by a manufacturer's warranty. Please refer to the warranty card included with your product or visit the official TROTEC webDie vollständigen Geschäftsbedingungen finden Sie auf der Website. Bewahren Sie Ihren Kaufbeleg für Garantieansprüche auf.
10.2. Kundendienst
For technical assistance, service, or spare parts, please contact TROTEC customer support:
- WebWebsite: www.trotec.com (Bitte prüfen Sie die lokalen Kontaktdaten)
- E-Mail: Weitere Informationen finden Sie im website for specific contact forms or email addresses.
- Telefon: Weitere Informationen finden Sie im webWebseite für regionale Telefonnummern.
When contacting support, please have your model number (TA300) and serial number (if applicable) ready.