Blodgett 20348

Blodgett 20348 Spark Box Assembly Instruction Manual

For Liquid Propane Ovens

1. Produktüberschreitungview

The Blodgett 20348 Spark Box Assembly is a genuine Original Equipment Manufacturer (OEM) replacement part designed for use with Blodgett commercial ovens that utilize liquid propane. This assembly is an essential component of the oven's ignition system, responsible for generating the spark required to ignite the gas, thereby ensuring reliable and safe operation.

Blodgett 20348 Spark Box Assembly, top-down view mit Schrauben

Bild 1.1: Draufsicht view of the Blodgett 20348 Spark Box Assembly, showing the main unit and included mounting screws.

2. Sicherheitshinweise

WARNUNG: Hohe Lautstärketage is present. Always disconnect power and gas supply to the appliance before installation, servicing, or maintenance to prevent electric shock and gas leaks.

  • Installation and servicing of this component should only be performed by a qualified service technician.
  • Ensure all gas connections are properly sealed and tested for leaks after installation.
  • Do not operate the oven if you smell gas. Immediately shut off the gas supply and ventilate the area.
  • Refer to the oven's main instruction manual for additional safety guidelines.

3. Packungsinhalt

Überprüfen Sie, ob alle Artikel im Paket vorhanden sind:

  • 1 x Blodgett 20348 Spark Box Assembly
  • Mounting Screws (approximately 6-8, as pictured)
Blodgett 20348 Spark Box Assembly with various screws scattered around it

Image 3.1: The Blodgett 20348 Spark Box Assembly shown with the accompanying mounting screws.

4. Einrichtung und Installation

This section provides general steps for replacing the spark box assembly. Always consult your specific oven's service manual for detailed, model-specific instructions.

  1. Den Backofen vorbereiten: Disconnect all electrical power and shut off the liquid propane gas supply to the oven.
  2. Alte Baugruppe suchen: Identify and locate the existing spark box assembly within the oven's control compartment.
  3. Trennen: Carefully disconnect all electrical wiring and any associated gas lines from the old assembly. Note the position and connection points of each wire for correct reinstallation.
  4. Alte Baugruppe entfernen: Unscrew and remove the old spark box assembly from its mounting location.
  5. Mount New Assembly: Position the new Blodgett 20348 Spark Box Assembly in the same location and secure it using the provided mounting screws.
  6. Verkabelung wiederherstellen: Reconnect all electrical wiring to the new assembly, ensuring each wire is attached to its correct terminal. Refer to the labels on the unit for guidance (e.g., GND, PV, THS, MV, SPARK).
  7. Reconnect Gas Lines: If applicable, reconnect any gas lines, ensuring all connections are tight and secure.
  8. Dichtheitsprüfung: After reconnecting gas lines, perform a leak test using an approved method (e.g., soap solution) to ensure there are no gas leaks.
  9. Strom- und Gasversorgung wiederherstellen: Once all connections are verified and secure, restore the gas supply and electrical power to the oven.
Seite view of Blodgett 20348 Spark Box Assembly showing wiring terminals and labels

Abbildung 4.1: Seite view of the spark box assembly, highlighting the various wiring terminals and their labels for correct connection.

5. Bedienung

The Blodgett 20348 Spark Box Assembly operates automatically as part of your oven's control system. When the oven thermostat calls for heat, the assembly receives a signal to initiate the ignition sequence. It then generates a high-voltage spark at the igniter electrode, which ignites the liquid propane gas flowing to the burner. A flame sensor confirms successful ignition, allowing the burner to continue operation. If ignition fails, the assembly will attempt to reignite or enter a lockout state, depending on the oven's control logic.

6. Wartung

The Blodgett 20348 Spark Box Assembly is designed for durability and typically requires minimal maintenance. However, periodic inspection is recommended:

  • Sichtprüfung: Annually, or as recommended by your oven's service schedule, visually inspect the assembly and its wiring for any signs of wear, corrosion, or damage.
  • Sauberkeit: Ensure the area around the spark box is kept clean and free from dust, grease, or other debris that could interfere with its operation or cause overheating.
  • Komponentenaustausch: Do not attempt to repair the spark box assembly. If it is found to be faulty or damaged, replace it with a genuine Blodgett 20348 part to ensure continued safety and performance.

7. Fehlerbehebung

The spark box assembly may indicate operational status or errors via an LED light. Refer to the labels on the unit for specific error codes:

  • DURCHGEHEND ROTE LED: Zeigt den Normalbetrieb an.
  • NO FLAME DURING TRIAL FOR IGNITION: If the burner fails to ignite, check the gas supply to the oven, verify the igniter electrode is clean and properly gapped, and ensure the flame sensor is functioning correctly.
  • INTERNAL ERROR: If the LED indicates an internal error, the spark box assembly is likely faulty and requires replacement.

If the oven fails to ignite or experiences intermittent ignition issues, consider the following:

  • Confirm the gas supply valve is open.
  • Check all electrical connections to the spark box assembly for tightness and correct wiring.
  • Inspect the igniter and flame sensor for damage or carbon buildup.
  • Wenn die Schritte zur Fehlerbehebung das Problem nicht lösen, wenden Sie sich an einen qualifizierten Servicetechniker.
Nahaufnahme von der Seite view of Blodgett 20348 Spark Box Assembly showing error code labels

Abbildung 7.1: Detailansicht view of the spark box assembly, showing the error code descriptions printed on the label.

8. Spezifikationen

MarkeBlodgett
Modellnummer20348
Produktabmessungen (L x B x H)5 x 5 x 9 Zoll
Artikelgewicht8 Unzen
InstallationstypEinschraubbar
Connector-GeschlechtMännlich
UrsprungslandVereinigte Staaten
Bandtage24 VAC, 50/60 Hz
Aktuell0.2A MAX
Betriebstemperatur-40 bis 80℃ (-40 bis 176℉)

9. Garantie und Support

For specific warranty information regarding your Blodgett 20348 Spark Box Assembly, please refer to the documentation provided with your original Blodgett oven or contact Blodgett customer service directly. Using genuine OEM replacement parts is recommended to ensure compatibility, optimal performance, and to maintain the validity of any existing warranties.

For technical support or further assistance, please visit the official Blodgett webBesuchen Sie die Website oder kontaktieren Sie deren autorisierte Serviceanbieter.

Zugehörige Dokumente - 20348

Vorview Blodgett 1415 Elektrischer Kompakt-Etagenbackofen: Installations-, Betriebs- und Wartungsanleitung
Ausführliche Installations-, Betriebs- und Wartungsanleitung für den Blodgett 1415 Elektro-Kompakt-Etagenbackofen, einschließlich Spezifikationen, elektrischer Anschlüsse, Montage, Bedienelemente, Reinigungsverfahren und Fehlerbehebung.
Vorview Kochanleitung für den Blodgett Combi Synergy-Ofen: Modi, Tipps und Rezepte
Eine umfassende Kochanleitung für den Blodgett Combi Synergy-Ofen mit detaillierten Beschreibungen der Dampf-, Heißluft- und Kombi-Modi, speziellen Techniken, Tipps zur Fehlerbehebung und ausführlichen Zeit- und Temperaturempfehlungen für verschiedene Lebensmittel.
Vorview Blodgett Export Series Gas Deck Ovens Installation and Operation Manual
Comprehensive installation and operation guidance for Blodgett Export Series Gas Deck Ovens, covering models 901, 911, 911-P, 951, 961, 961-P, 966, 981, 1048-B, and 1060-B. Includes safety, installation, operation, and maintenance procedures.
Vorview Installations-, Funktions- und Wartungshandbuch für vier Konvektionsgeräte von Blodgett DFG-100-K12-ES und DFG-200-K12-ES
Dieses Handbuch enthält detaillierte Anweisungen für die Installation, die Funktion und den Betrieb der vier Blodgett-Konvektionsmodelle DFG-100-K12-ES und DFG-200-K12-ES. Es enthält die technischen Daten, die Sicherheitsvorkehrungen und die Nutzungshinweise, um eine optimale Leistung zu gewährleisten.
Vorview Installations-, Funktions- und Wartungshandbuch für vier Konvektionsgeräte von Blodgett DFG-100-K12 und DFG-200-K12
Manuell abgeschlossen für die Installation, die Funktion und den Betrieb der vier Blodgett-Konvektionsmodelle DFG-100-K12 und DFG-200-K12. Einschließlich der Spezifikationen, der Sicherheitslieferungen, der Abfertigungs- und Abfertigungsverfahren.
Vorview Blodgett CTB & CTBR Elektro-Konvektionsofen: Service- und Reparaturhandbuch
Ausführliches Service- und Reparaturhandbuch für elektrische Konvektionsöfen der Modelle Blodgett CTB und CTBR, das Montage, Betrieb, Kalibrierung, Fehlersuche und Teileaustausch abdeckt.