SDC 1091AIV

SDC 1091AIV SpaceSaver Electric Bolt Lock

Bedienungsanleitung

Model: 1091AIV

1. Produktüberschreitungview

The SDC 1091AIV SpaceSaver Electric Bolt Lock is an advanced locking solution designed for access control applications. Its unique design allows the stainless steel bolt to project at right angles to the lock mechanism, facilitating installation in standard 1.75-inch frames or most door lock stiles with a simple cutout. This concealed installation enhances both aesthetics and security.

Hauptmerkmale:

  • Adjustable auto relock switch
  • Fits 1-3/4-inches minimum face frames
  • Failsafe - 12/24VDC standard operation
  • Failsecure - choice of 12 or 24VDC operation
  • Aluminum finish standard
SDC 1091AIV SpaceSaver Electric Bolt Lock

Image 1: The SDC 1091AIV SpaceSaver Electric Bolt Lock, showcasing its narrow profile and bolt mechanism, alongside its strike plate.

2. Sicherheitshinweise

Please read and understand all instructions before installation and operation. Failure to follow these instructions may result in product damage, property damage, or personal injury.

  • Professionelle Installation: Installation of this electric bolt lock should be performed by qualified personnel familiar with electrical systems and door hardware.
  • Elektrische Sicherheit: Ensure power is disconnected before performing any wiring or maintenance. Verify correct voltage (12VDC or 24VDC) is supplied to prevent damage to the unit.
  • Bandtage Kompatibilität: This unit operates on 12VDC or 24VDC. Connecting to an incorrect voltage source will damage the lock.
  • UL-Listung: This product is UL listed and UL 10C positive pressure compliant. Adhere to all local building codes and regulations during installation.

3. Einrichtung und Installation

3.1 Checkliste vor der Installation

  • Verify door frame material and dimensions. A minimum 1-3/4 inch frame is required.
  • Ensure appropriate power supply (12VDC or 24VDC) is available.
  • Gather necessary tools: measuring tape, drill, appropriate drill bits, screwdriver set, wiring tools.

3.2 Montage des Schlosses

  1. Carefully measure and mark the desired location for the lock body and strike plate on the door frame and door edge, respectively.
  2. Create the necessary cutout in the door frame for the lock body. The SpaceSaver design allows for a simple cutout.
  3. Secure the lock body into the cutout using the provided fasteners. Ensure it is flush with the frame surface for proper operation and aesthetics.
  4. Install the strike plate on the door edge, aligning it precisely with the bolt mechanism of the lock.

3.3 Verkabelung

The SDC 1091AIV supports both Failsafe and Failsecure configurations. Determine the required operation before wiring.

  • Failsafe Operation: The lock will unlock when power is removed. This is typically used for egress doors where safety requires the door to open during a power failure. Connect the power supply according to the Failsafe wiring diagram provided with the product packaging.
  • Failsecure Operation: The lock will remain locked when power is removed. This is typically used for security applications where the door must remain secured during a power failure. Connect the power supply according to the Failsecure wiring diagram provided with the product packaging.
  • Stellen Sie sicher, dass alle elektrischen Verbindungen sicher und isoliert sind, um Kurzschlüsse zu vermeiden.

3.4 Anpassungen

The lock features an adjustable auto relock switch. Refer to the detailed instructions in the product packaging for specific adjustment procedures to fine-tune the relock timing.

4. Bedienungsanleitung

The SDC 1091AIV Electric Bolt Lock operates in conjunction with an access control system or a simple switch, depending on the installation configuration.

  • To Unlock (Failsafe): Apply power to the lock. The bolt will retract, allowing the door to open. Removing power will cause the bolt to extend, locking the door.
  • To Unlock (Failsecure): Remove power from the lock. The bolt will retract, allowing the door to open. Applying power will cause the bolt to extend, locking the door.
  • The adjustable auto relock switch will automatically extend the bolt after a set delay once the door is closed and aligned with the strike plate.

5. Wartung

Regular maintenance ensures optimal performance and longevity of your SDC 1091AIV Electric Bolt Lock.

  • Inspektion: Periodically inspect the lock body, bolt, and strike plate for any signs of wear, damage, or misalignment. Ensure all fasteners are tight.
  • Reinigung: Clean the exterior surfaces with a soft, dry cloth. Avoid using abrasive cleaners, solvents, or harsh chemicals, as these can damage the finish.
  • Schmierung: If the bolt mechanism appears stiff or noisy, a small amount of silicone-based lubricant can be applied to the moving parts. Do not over-lubricate.
  • Verdrahtungsprüfung: Annually, inspect wiring connections for any signs of corrosion or loose terminals.

6. Fehlerbehebung

If you encounter issues with your SDC 1091AIV Electric Bolt Lock, refer to the following troubleshooting guide:

ProblemMögliche UrsacheLösung
Verriegelung rastet/löst nicht einNo power, incorrect wiring, bolt obstruction, misalignment.Check power supply, verify wiring against diagram, ensure no physical obstructions, adjust lock/strike plate alignment.
Intermittierender BetriebLoose wiring connections, fluctuating power supply, worn components.Secure all wiring connections, test power supply stability, inspect for wear.
Übermäßiger Lärm während des BetriebsLack of lubrication, mechanical interference, worn parts.Apply a small amount of silicone lubricant to moving parts, check for obstructions, consider professional inspection if noise persists.
Auto relock not functioningIncorrect adjustment, sensor issue, door not closing properly.Adjust the auto relock switch settings, ensure the door closes fully and aligns with the strike plate.

If troubleshooting steps do not resolve the issue, contact SDC technical support or a qualified technician.

7. Spezifikationen

BesonderheitDetail
MarkeDEZA
ModellnameSpaceSaver
Teilenummer1091AIV
SperrtypElectric Mortise Lock
MaterialAluminium
FarbeEdelstahl
StromquelleDC (12VDC / 24VDC)
BesonderheitTastensperre
Artikelgewicht1.45 Pfund
Verpackungsabmessungen10.8 x 3.4 x 2.4 Zoll
Minimum Frame Fit1-3/4 Zoll
KontrollmethodeApp (as per product specifications, verify compatibility with specific access control systems)
ZertifizierungenUL Listed, UL 10C Positive Pressure Compliant

8. Garantie und Support

For specific warranty information regarding your SDC 1091AIV SpaceSaver Electric Bolt Lock, please refer to the documentation included with your purchase or contact the seller or manufacturer directly.

For technical assistance, installation support, or to report any issues, please contact SDC customer service through their official webWebsite oder die beim Kauf angegebenen Kontaktinformationen.

Zugehörige Dokumente - 1091AIV

Vorview Installationsanleitung für das extra schmale, verdeckte Einsteckschloss SDC 1490AI Failsafe
Detaillierte Installationsanweisungen für das SDC 1490AI Failsafe Extra Narrow Concealed Mortise Bolt Lock, einschließlich Schaltplänen, technischen Daten und Tipps zur Fehlerbehebung.
Vorview SDC 2490AH Failsecure Extra Narrow verdecktes Einsteckschloss – Montageanleitung
Ausführliche Installationsanleitung für das verdeckte Einsteckschloss SDC 2490AH, einschließlich der Montage von oben und seitlich am Türrahmen, Verdrahtungskonfigurationen mit und ohne den Spannungsregler PR-1000, Fehlerbehebung und Maßangaben.
Vorview SDC 1291AHWD Ausfallsicheres verdecktes Einsteckschloss – Montageanleitung
Dieses Dokument enthält detaillierte Installationsanweisungen für das ausfallsichere, verdeckte Einsteckschloss SDC 1291AHWD, einschließlich Anleitungen zur horizontalen und vertikalen Montage, Schaltpläne, elektrische Spezifikationen und Hinweise zur Fehlerbehebung. Es beschreibt außerdem die Verwendung des Spannungsreglers PR-1000 und des ARS-Schalters.
Vorview Installationsanleitung für das ausfallsichere, verdeckte Einsteckschloss SDC 1190AIWD
Umfassende Installationsanleitung für das ausfallsichere, verdeckte Einsteckschloss SDC 1190AIWD, einschließlich Schaltplänen, technischen Daten und Tipps zur Fehlerbehebung.
Vorview Installationsanleitung für das ausfallsichere, verdeckte Einsteckschloss SDC 1091AI/1091AIDL
Umfassende Installationsanleitung für die ausfallsicheren verdeckten Einsteckschlösser SDC 1091AI und 1091AIDL. Enthält Schritt-für-Schritt-Anleitungen für die Überkopf- und Seitenrahmenmontage, Schaltpläne, Fehlerbehebung und technische Daten.
Vorview SDC 1291AH Ausfallsicheres verdecktes Einsteckschloss – Montageanleitung
Ausführliche Installationsanleitung für das ausfallsichere, verdeckte Einsteckschloss SDC 1291AH. Beinhaltet die Montage von oben und seitlich, Verdrahtungskonfigurationen mit und ohne den Spannungsregler PR-1000, Tipps zur Fehlerbehebung sowie detaillierte technische Spezifikationen für Metalltüren und -rahmen.