PeakTech P 4090

PeakTech P 4090 True RMS Bench Multimeter User Manual

Modell: P 4090

1. Einleitung

The PeakTech P 4090 is a high-precision True RMS Bench Multimeter designed for accurate electrical measurements in various applications. This versatile device offers a comprehensive range of functions, including True RMS measurement, diode and continuity testing, and relative value measurement. Featuring a clear 21mm LCD display, it ensures quick and easy reading of measured values. The integrated USB interface and accompanying PC software enable convenient data logging, analysis, and remote control, making it suitable for both laboratory and mobile service use.

PeakTech P 4090 True RMS Bench Multimeter front view

Abbildung 1: Vorderseite view of the PeakTech P 4090 True RMS Bench Multimeter.

2. Sicherheitshinweise

Always read this manual thoroughly before operating the PeakTech P 4090 Multimeter. Failure to follow safety instructions can result in electric shock, fire, or damage to the device. Keep this manual for future reference.

Hinteren view of PeakTech P 4090 Multimeter with safety warnings

Figure 2: Rear panel of the multimeter showing power input, USB port, and safety warnings.

3. Packungsinhalt

Upon unpacking your PeakTech P 4090 Multimeter, please verify that all the following items are present and in good condition:

4. Produktüberschreitungview

4.1 Frontplatte

Nahaufnahme von vorn view of PeakTech P 4090 Multimeter display and controls

Abbildung 3: Detaillierte Vorderseite view showing the LCD display, rotary switch, input jacks, and function buttons.

The front panel features the large 21mm LCD display, a central rotary switch for function selection, input jacks for test leads, and various push-buttons for additional functions.

4.2 Rückseite

Hinteren view of PeakTech P 4090 Multimeter showing power input, battery compartment, and USB port

Figure 4: Rear panel with power input, battery compartment, and USB interface.

The rear panel provides connections for power and data communication.

4.3 Kippständer

Seite view of PeakTech P 4090 Multimeter showing the integrated tilt stand

Abbildung 5: Seite view illustrating the adjustable tilt stand for optimal viewing-Winkel.

An integrated tilt stand on the underside of the multimeter allows for adjusting the viewing angle for improved ergonomics and readability.

5. Einrichtung

5.1 Powering the Multimeter

The PeakTech P 4090 can be powered by either AC mains or batteries for mobile use.

5.1.1 Einlegen der Batterie

  1. Ensure the multimeter is turned off and disconnected from any power source and test leads.
  2. Locate the battery compartment on the rear panel (refer to Figure 4).
  3. Schrauben Sie den Batteriefachdeckel ab und entfernen Sie ihn.
  4. Insert six (6) 1.5V R14C (UM2) batteries, observing the correct polarity (+/-).
  5. Bringen Sie die Abdeckung des Batteriefachs wieder an und befestigen Sie sie mit Schrauben.

5.1.2 Wechselstromanschluss

  1. Stellen Sie sicher, dass das Multimeter ausgeschaltet ist.
  2. Connect the provided power cord to the AC power input socket on the rear panel (refer to Figure 4).
  3. Plug the other end of the power cord into a suitable 220V 50Hz AC outlet.

5.2 Anschließen der Testleitungen

Always connect the test leads to the appropriate input jacks based on the measurement you intend to perform. Incorrect connection can lead to damage or inaccurate readings.

5.3 Software Installation (for Windows)

The PeakTech P 4090 includes PC software for data logging and analysis. Follow these steps to install:

  1. Legen Sie die mitgelieferte Software-CD in das CD/DVD-Laufwerk Ihres Computers ein.
  2. Follow the on-screen instructions to install the software. If the installer does not launch automatically, browse the CD and run the setup file.
  3. After installation, connect the multimeter to your computer using the supplied USB interface cable (refer to Figure 4 for USB port location).
  4. Launch the PeakTech DMM Tool software to begin data communication.
Screenshot of PeakTech DMM Tool software interface

Abbildung 6: Bspample screenshot of the PeakTech DMM Tool software interface.

6. Bedienungsanleitung

6.1 Ein-/Ausschalten

To turn the multimeter on, flip the power switch on the rear panel to the 'ON' position. To turn it off, flip the switch to 'OFF'.

6.2 Funktionsauswahl

Rotate the central rotary switch on the front panel to select the desired measurement function. The selected function will be indicated on the LCD display.

6.3 Tastenfunktionen

6.4 Basic Measurement Procedures

Always ensure the multimeter is set to the correct function and range, and test leads are connected properly before making any measurements.

  1. Bandtage Measurement (DC/AC):
    a. Connect the red lead to 'V Ω Temp' and the black lead to 'COM'.
    b. Set the rotary switch to 'V' (for DC or AC voltage). Use the MODE button to select DC or AC.
    c. Connect the test leads in parallel to the circuit or component to be measured.
  2. Strommessung (DC/AC):
    a. Connect the red lead to 'µA mA' or '10A' (depending on expected current) and the black lead to 'COM'.
    b. Set the rotary switch to 'µA mA' or '10A'. Use the MODE button to select DC or AC.
    c. Connect the multimeter in series with the circuit to be measured.
  3. Widerstandsmessung:
    a. Connect the red lead to 'V Ω Temp' and the black lead to 'COM'.
    b. Set the rotary switch to 'mV Hz Ω Temp'. Press MODE until 'Ω' is displayed.
    c. Connect the test leads across the component to be measured (ensure power is off for passive components).
  4. Durchgangsprüfung:
    a. Connect the red lead to 'V Ω Temp' and the black lead to 'COM'.
    b. Set the rotary switch to 'mV Hz Ω Temp'. Press MODE until the continuity symbol (speaker icon) is displayed.
    c. Touch the test leads to the points to be tested. A beep indicates continuity.
  5. Diodentest:
    a. Connect the red lead to 'V Ω Temp' and the black lead to 'COM'.
    b. Set the rotary switch to 'mV Hz Ω Temp'. Press MODE until the diode symbol is displayed.
    c. Connect the test leads across the diode. The display will show the forward voltage fallen.

7. Wartung

7.1 Reinigung

Um das Multimeter zu reinigen, wischen Sie das Gehäuse mit einem feuchten Tuch ab.amp cloth and a mild detergent. Do not use abrasives or solvents. Ensure the device is powered off and disconnected from all circuits and power sources before cleaning.

7.2 Batteriewechsel

When the low battery indicator appears on the display, replace the batteries promptly to ensure accurate measurements. Follow the steps outlined in Section 5.1.1 for battery installation.

7.3 Sicherungswechsel

If the current measurement function fails, the fuse may need replacement. Always replace fuses with the correct type and rating to prevent damage and ensure safety.

  1. Ensure the multimeter is turned off and disconnected from all power sources and test leads.
  2. Locate the fuse compartment, typically accessible by opening the main casing (refer to safety warnings in Section 2). This procedure should only be performed by qualified personnel.
  3. Replace the blown fuse with a new one of the identical type and rating:
    • For µA/mA input: F 200mA/250V, Ø 5x20mm
    • For 10A input: F 10A/MAX, 10 sec MAX EACH 15min (specific fuse type may vary, refer to device markings)
  4. Schließen Sie die c sicher.asing before resuming operation.

8. Fehlerbehebung

If you encounter issues with your PeakTech P 4090 Multimeter, refer to the following common troubleshooting steps:

Wenn das Problem nach diesen Schritten weiterhin besteht, wenden Sie sich bitte an den Kundendienst oder einen qualifizierten Servicetechniker.

9. Spezifikationen

BesonderheitSpezifikation
ModellTeil 4090
Anzeige21mm LCD, 22,000 counts
MesstypEchter Effektivwert
SicherheitsbewertungEN 61010-1; CAT I 600V
Wechselstromeingang200 ~ 240V AC / 50Hz
Gleichstromeingang6 x 1.5V R14C (UM2) batteries
Betriebstemperatur-20°C bis +100°C
Frequenzbereich20 Hz – 220 MHz
Abmessungen (L x B x H)32 x 27 x 10 cm
Gewicht2.8 kg
KonnektivitätUSB-Schnittstelle
HerstellerPeakTech
UPC042505694025

10. Garantie und Support

For warranty information, technical support, or service inquiries, please contact PeakTech directly. Refer to the official PeakTech webAuf dieser Website finden Sie die aktuellsten Kontaktdaten und Garantiebedingungen.

Hersteller: PeakTech
WebWebsite: www.peaktech.de

Zugehörige Dokumente - Teil 4090

Vorview PeakTech P 1073: 600V AC/DC Smart Digital Multimeter with NCV & Live-Test
Explore the PeakTech P 1073, a versatile 600V AC/DC smart digital multimeter featuring NCV, Live-Test, and True RMS capabilities. This compact device offers automatic function selection, a clear 4000-count LCD, and CAT III safety for precise electrical measurements.
Vorview PeakTech 1072/1073 Smart Digital-Multimeter Bedienungsanleitung
Umfassende Bedienungsanleitung für die PeakTech 1072 und 1073 Smart Digital-Multimeter. Erfahren Sie mehr über Funktionen, Sicherheitshinweise, Messmodi und technische Spezifikationen für präzise elektrische Messungen.
Vorview Bedienungsanleitung für das digitale Multimeter PeakTech 3441/3442
Ausführliche Bedienungsanleitung für die digitalen Multimeter PeakTech 3441 und 3442. Enthält Informationen zu Sicherheit, Bedienung, Funktionen wie True RMS und Bluetooth (3442) sowie technische Daten.
Vorview PeakTech 1072/1073 Smart Digital Multimeter Bedienungsanleitung
Ausführliche Bedienungsanleitung für die intelligenten Digitalmultimeter PeakTech 1072 und 1073 mit detaillierten Informationen zu Funktionen, Sicherheitshinweisen und Anwendungsrichtlinien.
Vorview PeakTech 2510 Leistungsanalysator Benutzerhandbuch
Ausführliches Benutzerhandbuch für den PeakTech 2510 Leistungsanalysator mit detaillierten Informationen zu Funktionen, Spezifikationen, Sicherheitsvorkehrungen und Bedienungsverfahren für elektrische Messungen.
Vorview PeakTech 2025 Digital Multimeter - Bedienungsanleitung & Technische Daten
Umfassende Bedienungsanleitung für das PeakTech 2025 Digitalmultimeter. Erfahren Sie mehr über Sicherheitshinweise, technische Daten, Messfunktionen und die optimale Nutzung dieses präzisen Messgeräts für Elektronik und Technik.