Einführung
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Raypak PR156AENC 150,000 BTU Natural Gas Pool Heater. Please read all instructions carefully before attempting to install or operate this unit. Retain this manual for future reference.
Sicherheitshinweise
WARNUNG: Eine unsachgemäße Installation, Einstellung, Änderung, Wartung oder Instandhaltung kann zu Sachschäden, Verletzungen oder zum Tod führen. Lesen Sie die Installations-, Betriebs- und Wartungsanweisungen sorgfältig durch, bevor Sie dieses Gerät installieren oder warten.
- Ensure all gas and electrical connections are performed by qualified personnel in accordance with local codes and ordinances.
- Lagern oder verwenden Sie kein Benzin oder andere brennbare Dämpfe und Flüssigkeiten in der Nähe dieses oder anderer Geräte.
- Never operate the heater if any part has been submerged in water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control that has been submerged in water.
- Halten Sie den Bereich um das Heizgerät frei von brennbaren Materialien, Benzin und anderen entzündlichen Dämpfen und Flüssigkeiten.
Setup und Installation
The Raypak PR156AENC heater is designed for above-ground pools and spas. Proper installation is critical for safe and efficient operation. It is highly recommended that installation be performed by a qualified and certified technician.
Elektrische Anforderungen:
- The unit requires either 120V or 240V electrical supply. Consult the wiring diagram located inside the heater's control panel for specific connections.
- The power cord provided is approximately 3 feet long. If replacement is necessary, use a cable rated for 304 degrees.
Gasanschluss:
- This heater operates on natural gas. Ensure your gas supply matches the heater's requirements.
- If your gas system is a 2 PSI system, an external gas regulator is required to reduce the pressure to approximately 1/4 PSI for proper ignition and operation. Failure to do so may result in ignition issues.
Wasseranschlüsse:
- The heater features 2-inch water connections. Ensure proper plumbing and sealing to prevent leaks.

Abbildung 1: Vorderseite view of the Raypak PR156AENC Natural Gas Pool Heater, showing the control panel and general casing.
Bedienungsanleitung
Once installed and all connections are verified, follow these steps for basic operation:
- Einschalten: Ensure the heater is connected to a power source and the main power switch is in the "ON" position.
- Gasversorgung: Verify that the natural gas supply valve to the heater is open.
- Wasserdurchfluss: Confirm that water is flowing through the heater from your pool or spa pump. The heater will not operate without adequate water flow.
- Temperatur einstellen: Use the digital control panel to set your desired water temperature. The LCD screen will display the current and set temperatures.
- Zündung: The heater will automatically initiate its ignition sequence. If ignition fails, the system will attempt to re-ignite. Refer to the troubleshooting section if repeated ignition failures occur.
- Überwachung: Periodically check the LCD screen for operational status and any error codes.

Abbildung 2: Nahaufnahme view of the Raypak PR156AENC heater's control panel, typically featuring an LCD display and control buttons.
Wartung
Regular maintenance ensures the longevity and efficient performance of your Raypak pool heater. Always disconnect power and gas supply before performing any maintenance.
- Wasserchemie: Maintain proper pool/spa water chemistry, especially pH levels. Incorrect pH can lead to corrosion and damage to internal components like the heat exchanger.
- Sauberkeit: Keep the area around the heater clean and free of debris, leaves, and other obstructions that could block airflow or create fire hazards.
- Überwinterung: In colder climates, proper winterization procedures are essential to prevent freeze damage. Consult a qualified technician or your local dealer for specific instructions.
- Jährliche Inspektion: It is recommended to have a qualified service technician inspect the heater annually to check for wear, leaks, and proper operation of safety devices.
Fehlerbehebung
This section addresses common issues you might encounter with your heater. For complex problems, contact a qualified service technician.
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Heater not igniting / "Rollout Switch Error" | Insufficient gas pressure; faulty rollout switch; blocked flue. |
|
| LCD screen is blank or flickering | Faulty LCD display board. | The LCD display board (Raypak 013640F) may need to be replaced. This can often be done by a user with technical aptitude. |
| Water leaking from the heater | Damaged heat exchanger; loose plumbing connections; corrosion due to improper water chemistry. |
|
| Heater not heating effectively | Low gas pressure; inadequate water flow; incorrect temperature setting; dirty burner. |
|
Technische Daten
| Besonderheit | Detail |
|---|---|
| Modellnummer | P-R156A-EN-C |
| Teilenummer | 014784 |
| BTU-Bewertung | 150,000 BTU |
| Kraftstoffart | Erdgas |
| Bandtage | 120 V oder 240 V |
| Wasseranschlüsse | 2 Zoll |
| Elevation Rating | 0-4999 Fuß |
| Abmessungen (L x B x H) | 27.5 x 27 x 12 Zoll |
| Artikelgewicht | 100 Pfund |
| Material | Polymer Headers (corrosion resistant) |
| Montagetyp | Bodenhalterung |
| Besondere Merkmale | Energieeffizient |
| Verwendung | Above-Ground Pools and Spas |
Garantieinformationen
Raypak provides specific warranty terms for its products. It is important to understand these terms:
- Customer Installed Units: A warranty period of 90 days from the date of purchase typically applies to units installed by the customer.
- Professionally Installed Units: The warranty period may be extended up to 1 year if the unit is installed by a technician certified by the manufacturer. Proof of professional installation (e.g., receipt from a certified technician) is usually required to validate the extended warranty.
Always retain your proof of purchase and installation records. Warranty claims are subject to inspection and adherence to installation and maintenance guidelines, including proper water chemistry.
Kundenservice
For technical assistance, parts, or warranty inquiries, please contact Raypak customer service. Ensure you have your model number (P-R156A-EN-C) and part number (014784) available when contacting support.
You can visit the official Raypak webWebseite für Kontaktinformationen und weitere Ressourcen: Raypak Store on Amazon