Elitech RC-4HC

Elitech RC-4HC Datenlogger für Temperatur und Luftfeuchtigkeit

Bedienungsanleitung

Produkt überview

The Elitech RC-4HC is a versatile temperature and humidity data logger designed for precise monitoring. It features a multifunction LCD alarm indicator and a buzzer alarm, making it suitable for various applications requiring accurate environmental data. Data can be easily exported in PDF or Excel formats using the Elitech data management software. The device supports both internal and external temperature sensors for enhanced flexibility.

Elitech RC-4HC data logger with external probe

Figure 1: Elitech RC-4HC Temperature and Humidity Data Logger with external temperature probe.

Setup und Installation

1. Einlegen der Batterie

The RC-4HC data logger requires a CR2450 battery for operation. Follow these steps to install the battery:

  1. Suchen Sie das Batteriefach auf der Rückseite des Geräts.
  2. Use a coin or a flat tool to gently twist and open the battery cover.
  3. Place the CR2450 battery under the small metal clip, ensuring the positive pole (marked with a plus sign) is facing upwards.
  4. Bringen Sie die Batterieabdeckung wieder an und drehen Sie sie fest.
Steps for installing battery in Elitech RC-4HC

Figure 2: Step-by-step guide for battery installation in the RC-4HC data logger.

2. Connecting the External Temperature Sensor

For applications requiring external temperature measurement, connect the provided external sensor to the designated port on the side of the data logger. The external sensor has a cable length of 1.1 meters.

Elitech RC-4HC with external temperature sensor

Figure 3: The RC-4HC data logger with its external temperature sensor connected.

3. Softwareinstallation und Verbindung

To configure the logger and download data, you will need the Elitech data management software. This software can be downloaded from the official Elitech website. Once installed, connect the data logger to your computer using the provided USB cable.

Elitech RC-4HC connected to a laptop via USB

Figure 4: Connecting the RC-4HC data logger to a computer via USB cable.

Bedienungsanleitung

1. Starten und Beenden der Protokollierung

To start the data logger, press the button on the device once to light up the screen. Then, press and hold the button for more than 4 seconds. A triangle sign firmly lit up on the logger screen indicates that logging has successfully started. To stop logging, connect the logger to the computer and use the software.

2. ViewDaten auf dem Gerät speichern

While the logger is active, press the button briefly to cycle through various display parameters including current temperature, humidity, total logged points, current time, date, maximum temperature, minimum temperature, and upper/lower temperature limits.

3. Configuring Parameters via Software

After connecting the logger to your computer, open the Elitech data management software. Navigate to the "Parameter" tab to adjust settings such as the log interval (e.g., to 10 seconds), alarm limits, and temperature unit (°C/°F). Remember to click the "Save Parameter" button after making changes. This action will also clear previous data and prepare the logger for new recording sessions.

4. Data Download and Export

Once connected to the software, you can download the recorded data. The Elitech software allows you to export data in various formats, including PDF and Excel, for easy analysis and reporting.

Software export options for Elitech RC-4HC data

Figure 5: Data export options available in the Elitech data management software.

Official Product Video: Setup and Operation

Video 1: This video demonstrates the initial setup, battery installation, external sensor connection, and basic operation of the Elitech RC-4HC data logger, including connecting to the computer and using the software for parameter settings and data download.

Wartung

To ensure the longevity and accuracy of your Elitech RC-4HC data logger, follow these maintenance guidelines:

Fehlerbehebung

If you encounter issues with your Elitech RC-4HC data logger, consider the following common solutions:

Technische Daten

The Elitech RC-4HC data logger offers the following technical specifications:

Temperaturmessbereich-30℃~+60℃ (internal sensor); -40℃~+85℃ (external sensor)
Temperaturgenauigkeit±0.5 °C (-30 °C bis +60 °C); ±1.0 °C (andere)
Temperatureinheit℃ / ℉ (selectable via software)
Luftfeuchtigkeitsmessbereich0 bis 99 % relative Luftfeuchtigkeit
Feuchtigkeitsgenauigkeit±3%RH (25℃, 20~90%RH); ±5%RH (others)
AuflösungTemperature 0.1℃; Humidity 0.1%RH
Kapazität aufzeichnen16000 Punkte (MAX)
Aufzeichnungsintervall10s~24h einstellbar
Connect-SchnittstelleUSB-Schnittstelle
StromversorgungCR2450 battery or power supply via USB interface
AkkulaufzeitAbove one year (at normal temperature, 15-minute record interval)
Ambient Environmental Temperature-30℃~+60℃
Produktgröße84 mm (Länge) x 44 mm (Breite) x 20 mm (Höhe)
Logger Weight40g
Im Paket enthalten1x RC-4HC Data logger, 1x External Temperature Sensor (1.1m), 1x USB cable, 1x Battery, 1x Manual
Elitech RC-4HC dimensions

Figure 6: Dimensions of the Elitech RC-4HC data logger.

Lieferumfang des Elitech RC-4HC

Figure 7: Contents included in the Elitech RC-4HC package.

Garantie und Support

Elitech Technology Inc. stands behind the quality of its products. For warranty information, technical support, or any inquiries regarding your RC-4HC data logger, please contact Elitech directly.

The product was first available on August 18, 2014.

Zugehörige Dokumente - RC-4HC

Vorview Elitech RC-4/RC-4HA/RC-4HC Datenlogger – Kurzanleitung | Installation und Konfiguration
Kurzanleitung für die Datenlogger Elitech RC-4, RC-4HA und RC-4HC. Erfahren Sie, wie Sie Batterien einsetzen, Software einrichten, Einstellungen konfigurieren, die Protokollierung starten/stoppen und häufige Probleme beheben. Enthält detaillierte technische Daten zur Temperatur- und Feuchtigkeitsüberwachung.
Vorview Elitech RC-4/RC-4HA/RC-4HC Datenlogger – Kurzanleitung
Eine prägnante Kurzanleitung für die Datenlogger Elitech RC-4, RC-4HA und RC-4HC mit wichtigen Hinweisen zur Batterieinstallation, Softwareeinrichtung, Bedienung des Loggers, Konfiguration und Fehlerbehebung.
Vorview Elitech RC-4 / RC-4HC Benutzerhandbuch
Benutzerhandbuch für die Temperatur- und Feuchtigkeitsdatenlogger Elitech RC-4 und RC-4HC. Enthält Spezifikationen, Bedienung, Statusanzeige und Informationen zum Batteriewechsel.
Vorview Elitech RC-4 Serie Temperatur- und Feuchtigkeitsdatenlogger – Benutzerhandbuch & Spezifikationen
Ausführliches Benutzerhandbuch und technische Daten für die Temperatur- und Feuchtigkeitsdatenlogger der Serien Elitech RC-4 und RC-4HC. Erfahren Sie mehr über Bedienung, Einrichtung, Datenaufzeichnung und Funktionen für das Kühlkettenmanagement.
Vorview Elitech RC-4 Serie Temperatur- und Feuchtigkeitsdatenlogger - Benutzerhandbuch
Ausführliches Benutzerhandbuch für die Temperatur- und Feuchtigkeitsdatenlogger der Serien Elitech RC-4 und RC-4HC. Beinhaltet Spezifikationen, Bedienung, Einrichtung und Fehlerbehebung für die Kühlkettenüberwachung.
Vorview Elitech RC-4/RC-4HC Temperatur- und Feuchtigkeitsdatenlogger – Benutzerhandbuch
Dieses Benutzerhandbuch enthält umfassende Anweisungen für den Betrieb und die Wartung der Temperatur- und Feuchtigkeitsdatenlogger Elitech RC-4 und RC-4HC. Es behandelt Produktmerkmale, Bedienung, Parameterkonfiguration und Datenerfassung. viewInformationen zu Versand und Export, Batteriewechsel, Spezifikationen, Vorsichtsmaßnahmen und Garantie.