Fluidmaster 400ACN3P5

Bedienungsanleitung für das Fluidmaster 400ACN3P5 Toilettenfüllventil

Model: 400ACN3P5

Einführung

This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of your Fluidmaster 400ACN3P5 Toilet Fill Valve. Please read these instructions carefully before beginning installation to ensure proper function and longevity of the product.

Sicherheitshinweise

  • Vor Beginn jeglicher Arbeiten muss die Wasserzufuhr zur Toilette abgestellt werden.
  • Tragen Sie während der Installation geeignete persönliche Schutzausrüstung, wie z. B. eine Schutzbrille.
  • Do not overtighten nuts or connections, as this may cause damage or leaks.
  • Wenn Sie sich bei einem Arbeitsschritt unsicher sind, konsultieren Sie einen qualifizierten Klempner.

Packungsinhalt

Your Fluidmaster 400ACN3P5 Toilet Fill Valve package typically includes:

  • Fluidmaster 400ACN3P5 Toilet Fill Valve
  • Nachfülltube
  • Nachfüllclip
  • Schaftscheibe
  • Kontermutter
Fluidmaster 400ACN3P5 Toilet Fill Valve Contractor Pack

Abbildung 1: Packaging for the Fluidmaster 400ACN3P5 Toilet Fill Valve. This image shows a "Three Pack" configuration. Actual package contents may vary based on the specific product variant purchased (e.g., single pack, 5-pack).

Einrichtung: Installationsanleitung

  1. Wasserzufuhr abstellen: Locate the water supply valve at the base of the toilet and turn it clockwise until the water flow stops completely.
  2. Spültoilette: Flush the toilet to drain most of the water from the tank. Hold the flush handle down to ensure as much water as possible is removed.
  3. Restwasser entfernen: Use a sponge or towel to remove any remaining water from the toilet tank.
  4. Versorgungsleitung trennen: Disconnect the water supply line from the bottom of the old fill valve. Have a small bucket ready to catch any residual water.
  5. Altes Füllventil ausbauen: Loosen the lock nut on the underside of the toilet tank that secures the old fill valve. Remove the old fill valve from the tank.
  6. Neues Füllventil einbauen: Insert the new Fluidmaster 400ACN3P5 fill valve into the hole at the bottom of the toilet tank. Ensure the shank washer is properly seated on the outside of the tank.
  7. Secure Fill Valve: Hand-tighten the lock nut onto the threaded shank of the new fill valve from the underside of the tank. Do not overtighten.
  8. Connect Water Supply Line: Reconnect the water supply line to the bottom of the new fill valve. Hand-tighten, then use a wrench for a final quarter-turn, being careful not to overtighten.
  9. Attach Refill Tube: Attach one end of the refill tube to the small port on the top of the fill valve. Clip the other end of the refill tube to the overflow pipe using the refill clip, ensuring the tube is above the water level in the tank.
  10. Adjust Fill Valve Height (if applicable): Some Fluidmaster models allow for height adjustment. If your model has this feature, adjust the height so the critical level mark (C.L.) on the valve is at least 1 inch above the top of the overflow pipe.
  11. Wasserversorgung einschalten: Slowly turn the water supply valve counter-clockwise to restore water flow to the toilet tank.
  12. Auf Lecks prüfen: Carefully inspect all connections for any signs of leaks. Tighten connections slightly if necessary.
  13. Wasserstand anpassen: Allow the tank to fill. The water level should stop approximately 1 inch below the top of the overflow pipe. If adjustment is needed, refer to the specific instructions for your fill valve model (often involves a screw or clip adjustment on the valve itself).

Bedienungsanleitung

The Fluidmaster 400ACN3P5 Toilet Fill Valve operates automatically. After each flush, the valve senses the drop in water level and opens to refill the toilet tank to the preset level. Once the desired water level is reached, the valve automatically shuts off the water flow. The refill tube ensures that a small amount of water is directed into the toilet bowl during the refill cycle, maintaining the water seal in the bowl.

Wartung

  • Regelmäßige Inspektion: Periodically inspect the fill valve for any signs of wear, cracks, or mineral buildup.
  • Reinigung: If the valve appears to be operating slowly or making unusual noises, mineral deposits may be affecting its performance. Turn off the water supply, remove the cap of the fill valve (refer to specific model instructions for cap removal), and gently clean any visible debris or mineral buildup. Rinse with clean water.
  • Check Refill Tube: Ensure the refill tube is securely attached and not kinked or obstructed.

Fehlerbehebung

Die Toilette läuft ununterbrochen.

  • Water Level Too High: Adjust the fill valve to lower the water level in the tank. The water level should be about 1 inch below the top of the overflow pipe.
  • Flapper Leak: Check the toilet flapper for proper sealing. A worn or misaligned flapper can cause water to leak into the bowl, making the fill valve run intermittently to refill the tank.
  • Refill Tube Too Low: Ensure the refill tube is clipped above the water level in the tank and not inserted directly into the overflow pipe.

Toilet Fills Slowly or Not at All

  • Water Supply Off: Ensure the water supply valve to the toilet is fully open.
  • Obstructed Inlet: Turn off the water, disconnect the supply line, and check the fill valve's inlet screen for debris. Clean if necessary.
  • Mineralstoffansammlung: Follow maintenance steps to clean the fill valve mechanism.

Fill Valve Makes Noise

  • Wasserdruck: High water pressure can sometimes cause noise. A pressure reducing valve for the whole house might be considered.
  • Lose Teile: Ensure all connections are secure but not overtightened.
  • Mineralstoffansammlung: Clean the valve as described in the maintenance section.

Technische Daten

BesonderheitDetail
MarkeFluidmaster
Modellnummer400ACN3P5
MaterialMessing
AußenverkleidungChrome-Plated Brass
EinlassverbindungstypGewinde
Anzahl der Ports2
Artikelgewicht3 Pfund
Technische Daten9 x 19 x 14 Zoll
UPC039961400031
ZertifizierungenASME, NSF, ULC, UL, IAPMO, EPA, WaterSense, CE, ASSE

Garantieinformationen

The Fluidmaster 400ACN3P5 Toilet Fill Valve comes with a 1-year limited warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims. For full warranty details, please refer to the official Fluidmaster webWebsite oder wenden Sie sich an den Kundendienst.

Unterstützung

For further assistance, technical support, or to inquire about replacement parts, please visit the official Fluidmaster webWebsite oder wenden Sie sich an die Kundendienstabteilung.

WebWebsite: www.fluidmaster.com

Kundendienst: Refer to the Fluidmaster webAuf dieser Webseite finden Sie Kontaktnummern und Öffnungszeiten.

Zugehörige Dokumente - 400ACN3P5

Vorview Fluidmaster K-400H-021 „The Everything“ Toilettentank-Reparaturset – Installationsanleitung
Umfassende Installationsanleitung für das Fluidmaster K-400H-021 „The Everything“-Reparaturset für Toilettenspülkästen. Erfahren Sie, wie Sie Spülventil, Füllventil und andere Komponenten für optimale Toilettenleistung austauschen. Enthält Schritt-für-Schritt-Anleitungen, Fehlerbehebung und Garantieinformationen.
Vorview Anleitung zum Austausch des Füllventils Fluidmaster 703A5B
Ausführliche Anleitung zum Austausch des Fluidmaster 703A5B Füllventils. Enthält Schritt-für-Schritt-Anweisungen für Ausbau, Dichtungswechsel und Spülung von Ablagerungen sowie detaillierte Beschreibungen und Diagramme für ein klares Verständnis.
Vorview Fluidmaster 400H PerforMAX Füllventil – Kurzanleitung zur Installation
Schritt-für-Schritt-Anleitung zur Installation und Fehlerbehebung des Fluidmaster 400H PerforMAX Toilettenfüllventils. Enthält Teile überview, benötigte Werkzeuge und Garantieinformationen.
Vorview Installationsanleitung für das Fluidmaster 540T Einzelspülventil | Reparatur und Austausch von Toilettenteilen
Schritt-für-Schritt-Installationsanleitung für das Fluidmaster 540T Einzelspülventil. Erfahren Sie, wie Sie das Spülventil Ihrer Toilette einfach und sicher austauschen. Enthält Warnhinweise und Garantieinformationen.
Vorview Fluidmaster K-400A-023 Mansfield Reparaturset – Kurzanleitung
This quick installation guide provides clear, step-by-step instructions for fitting the Fluidmaster K-400A-023 Mansfield Repair Kit. It is designed to help users efficiently replace toilet tank components, ensuring optimal performance and water conservation.
Vorview Installationsanleitung für das Fluidmaster DUO FLUSH™-System
Umfassende Installationsanleitung für das Fluidmaster DUO FLUSH™ System, einschließlich Teile überview, Schritt-für-Schritt-Anleitungen zur Installation des DUO FLUSH™-Ventils, des PerforMAX™-Füllventils, des Dual Action-Griffs und Tipps zur Fehlerbehebung.