1. Einleitung
This manual provides instructions for the installation, operation, and maintenance of the Westek In-Wall Programmable Digital Timer, Model ATW-T24. This device is designed to add automated programming functionality to various electrical devices such as lights, heaters, and fans. It features an LCD display for easy programming and a rechargeable battery backup to retain settings during power interruptions.
The timer supports up to 7 weekly programs and includes a random option for enhanced security.
2. Sicherheitshinweise
WARNUNG: To avoid fire, shock, or death; turn off power at the circuit breaker or fuse box and test that the power is off before wiring. All wiring should be performed by a qualified electrician or in accordance with local electrical codes. This device is for indoor use only. Do not exceed the specified electrical ratings.
- Vor Installation oder Wartung immer die Stromzufuhr unterbrechen.
- Stellen Sie sicher, dass alle Verbindungen sicher und ordnungsgemäß isoliert sind.
- Nicht bei Nässe oder damp Standorte.
- Außerhalb der Reichweite von Kindern aufbewahren.
3. Packungsinhalt
The package for the Westek In-Wall Programmable Digital Timer (Model ATW-T24) includes:
- One (1) Westek In-Wall Programmable Digital Timer, 120 V, 1 HP
- One (1) Lithium Ion battery (pre-installed)

Bild 1: Vorderseite view of the Westek In-Wall Programmable Digital Timer. The timer features a white faceplate with a digital display and control buttons.
4. Installation
Installation of this in-wall timer requires electrical wiring knowledge. If you are unsure about any part of the installation process, consult a qualified electrician.
- Strom ausschalten: Locate the circuit breaker or fuse that supplies power to the switch box where the timer will be installed. Turn off the power completely. Verify power is off using a voltage Tester.
- Vorhandenen Switch entfernen: Entfernen Sie vorsichtig die Abdeckplatte und schrauben Sie den vorhandenen Schalter aus der Unterputzdose. Trennen Sie die Kabel vom alten Schalter.
- Schließe den Timer an: Connect the wires to the Westek timer according to the wiring diagram provided with the product packaging. Typically, this involves connecting line (hot), load, and ground wires. Ensure all connections are tight and secure.
- Zeitschaltuhr montieren: Gently push the wired timer into the wall box. Secure it with the provided screws.
- Wandplatte installieren: Attach the new or existing wall plate over the timer.
- Strom wiederherstellen: Schalten Sie den Strom am Sicherungsautomaten oder Sicherungskasten wieder ein.

Image 2: The Westek In-Wall Programmable Digital Timer shown with its internal components and wiring connections. This image illustrates the back of the timer where electrical connections are made.
5. Bedienungsanleitung
The Westek In-Wall Programmable Digital Timer allows for flexible scheduling of connected devices. The LCD display and control buttons facilitate programming.
5.1 Erste Einrichtung und Zeiteinstellung
- Upon initial power-up or after a prolonged power outage, the display may show a default time or require setting.
- Use the designated buttons (e.g., "SET," "HOUR," "MINUTE," "DAY") to adjust the current time and day of the week. Refer to the specific button labels on your device for precise controls.
- Confirm the settings to save the current time.
5.2 Programmierung von Ein-/Ausschaltzyklen
The timer supports up to 7 custom weekly programs.
- Press the "PROG" or "PROGRAM" button to enter programming mode.
- The display will typically show "PROG 1 ON" or similar. Use the "HOUR," "MINUTE," and "DAY" buttons to set the desired ON time and days for the first program.
- Press "PROG" again to set the "PROG 1 OFF" time and days.
- Repeat for up to 7 programs as needed.
- Exit programming mode by pressing a dedicated "RUN" or "CLOCK" button, or by allowing the timer to time out.
5.3 Random Option
To deter intruders, the timer includes a random ON/OFF feature. When activated, the timer will randomly vary the programmed ON/OFF times by a small interval (e.g., +/- 30 minutes) to simulate occupancy.
- Locate the "RANDOM" or "RND" button.
- Press it to activate or deactivate the random function. An indicator on the LCD may confirm its status.
5.4 Manuelle Übersteuerung
Most digital timers allow for a temporary manual override of the current program without erasing es.
- Press the "MANUAL" or "ON/OFF" button to toggle the connected device on or off, overriding the current program until the next programmed event.
5.5 Notstromversorgung
The integrated rechargeable Lithium Ion battery maintains the time and programmed settings during power outages. The battery recharges automatically when main power is restored.
6. Wartung
The Westek In-Wall Programmable Digital Timer requires minimal maintenance.
- Reinigung: To clean the timer, wipe the surface with a soft, dry cloth. Do not use abrasive cleaners, solvents, or spray directly onto the unit.
- Batterie: The internal rechargeable battery is designed for long-term use and typically does not require replacement. If the timer consistently loses settings during power outages, the battery may need servicing by a qualified technician.
7. Fehlerbehebung
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Der Timer lässt sich nicht einschalten. | No power to the switch box; incorrect wiring. | Prüfen Sie den Leitungsschutzschalter/die Sicherung. Stellen Sie sicher, dass die Verdrahtungsanschlüsse korrekt und fest sitzen. |
| Device does not turn ON/OFF as programmed. | Incorrect program settings; manual override active. | Review and re-enter program settings. Check if manual override is active and deactivate if necessary. |
| Das LCD-Display ist schwer lesbar. | Poor lighting conditions; display angle. | Ensure adequate ambient lighting. Adjust viewWenn möglich, den Winkel anpassen. |
| Timer verliert Einstellungen nach Stromausfalltage. | Rechargeable battery backup not functioning. | Allow time for the battery to recharge. If problem persists, contact customer support. |
| Difficulty programming the timer. | Unkenntnis der Programmierschritte. | Carefully follow the operating instructions in Section 5. Practice programming without a connected load if possible. |
8. Spezifikationen
- Marke: Westek
- Modellnummer: ATW-T24
- Teilenummer: TMDW30CC
- Bandtage: 120 V
- Leistung (PS): 1 PS
- Material: Plastik
- Farbe: Weiß
- Artikelgewicht: 5.9 Unzen
- Produktabmessungen: 1.25 x 1.75 x 3 Zoll
- Batterien: 1 Lithium-Ionen-Akku (im Lieferumfang enthalten)
- Schalterstil: Umschalten
- UPC: 700814916251, 889932723870, 070686506066, 696746170994
- Als Erstes verfügbar: 26. Juli 2005
9. Garantie und Support
Garantiebeschreibung: The manufacturer states "Not applicable" for warranty information. Please refer to your retailer's return policy for details on returns or exchanges.
For technical assistance or further inquiries, please contact Westek customer support through their official webWebsite oder den Händler, bei dem das Produkt gekauft wurde.