1. Einleitung
The Aeotec Multisensor 6 is a Z-Wave Plus enabled device designed to provide comprehensive environmental monitoring for your smart home system. This compact sensor integrates six different detection capabilities into a single unit: motion, temperature, humidity, ambient light, ultraviolet (UV) light, and vibration. It utilizes the Z-Wave 500 series chip for enhanced wireless range and communication speed, and includes AES 128-bit security encryption.
This manual provides detailed instructions for setting up, operating, maintaining, and troubleshooting your Multisensor 6 to ensure optimal performance and integration with your Z-Wave network.
2. Lieferumfang
Carefully unpack the contents of your Multisensor 6 package. The following items should be included:
- Aeotec Multisensor 6 Unit
- Batterieabdeckung
- Rückseitiger Arm
- Doppelseitiges Klebeband
- Schrauben (×2)
- Micro-USB-Kabel

Abbildung 2.1: Contents of the Multisensor 6 package.
3. Produktüberschreitungview
The Aeotec Multisensor 6 is a versatile device capable of detecting multiple environmental parameters:
- Bewegungssensor: Erkennt Bewegungen innerhalb seines Sichtfelds view.
- Temperatursensor: Misst die Umgebungstemperatur.
- Feuchtigkeitssensor: Monitors the relative humidity of the environment.
- Lichtsensor: Measures ambient light levels (lux).
- UV-Sensor: Detects ultraviolet light, providing data on UV index.
- Vibrationssensor: Functions as a tamper switch, detecting physical disturbance.

Abbildung 3.1: Abgewinkelt view of the Multisensor 6.
4. Einrichtung
4.1 Einschalten des Geräts
The Multisensor 6 can be powered in two ways:
- Batterieleistung: Insert two (2) CR123A batteries into the battery compartment. Ensure correct polarity.
- USB-Stromversorgung: Connect the provided Micro USB cable to the sensor's USB port and to a DC 5V 500mA power adapter (not included).
Using USB power allows the sensor to operate in a more frequent reporting mode, while battery power conserves energy for longer operation between changes.

Abbildung 4.1: Hinteren view of the Multisensor 6 with power input.
4.2 Z-Wave Network Inclusion (Pairing)
To integrate the Multisensor 6 into your Z-Wave network, follow these steps:
- Place your Z-Wave gateway/hub into inclusion (pairing) mode. Refer to your gateway's manual for specific instructions.
- Bring the Multisensor 6 close to your Z-Wave gateway.
- Press the Action Button on the Multisensor 6 once. The LED indicator will flash to confirm inclusion mode.
- If inclusion is successful, the LED will stop flashing and remain solid for a few seconds before turning off. The Multisensor 6 will appear in your Z-Wave controller's device list.
- If inclusion fails, the LED will flash rapidly for a longer period. Repeat the steps or try Z-Wave exclusion first (see Section 6.1).
Notiz: For optimal performance and to utilize all features, ensure your Z-Wave gateway supports Z-Wave 500 series devices and is updated to the latest firmware.
5. Bedienungsanleitung
Once successfully included in your Z-Wave network, the Multisensor 6 will begin reporting data from its various sensors to your Z-Wave gateway. You can typically view and manage these sensor readings through your Z-Wave controller's interface or associated smart home application.
5.1 Sensor Readings
- Bewegung: Reports motion detection (ON/OFF).
- Temperatur: Provides temperature readings in Fahrenheit or Celsius.
- Luftfeuchtigkeit: Reports relative humidity as a percentage.
- Licht: Reports ambient light in lux.
- UV: Reports the UV index.
- Vibration: Berichte tamper events (ON/OFF).
5.2 Konfigurationsparameter
The Multisensor 6 offers various configuration parameters that can be adjusted via your Z-Wave gateway to customize its behavior, such as reporting intervals, motion sensitivity, and LED indicator behavior. Consult your Z-Wave gateway's documentation and the Aeotec Multisensor 6 technical specifications for a complete list of configurable parameters and their values.
6. Installation
The Multisensor 6 offers flexible installation options to suit various environments.
6.1 Montagemöglichkeiten
- Oberflächenplatzierung: The sensor can be placed on any flat surface, such as a shelf or table.
- Schraubmontage: Use the provided screws and back-mount arm to securely attach the sensor to a wall or ceiling.
- Klebemontage: Utilize the double-sided tape for a less permanent mounting solution on flat surfaces.
6.2 Optimale Platzierung
- For motion detection, place the sensor where it has a clear line of sight to the area you wish to monitor. The motion sensor has a 16-foot range and a 120° field of view.
- Avoid placing the sensor near heat sources, direct sunlight, or strong drafts, as these can affect temperature and humidity readings.
- Ensure the sensor is within reliable Z-Wave range of your gateway for consistent communication.

Abbildung 6.1: Seite view of the Multisensor 6.
7. Wartung
7.1 Batteriewechsel
When operating on battery power, the Multisensor 6 will report its battery level to your Z-Wave gateway. When the battery level is low, replace the batteries:
- Gently twist the sensor unit counter-clockwise to detach it from its mounting base.
- Entfernen Sie die Batterieabdeckung.
- Entfernen Sie die alten CR123A-Batterien.
- Legen Sie zwei neue CR123A-Batterien ein und achten Sie dabei auf die richtige Polarität.
- Replace the battery cover and reattach the sensor unit to its base by twisting clockwise.
Notiz: Always use fresh, high-quality batteries for optimal performance and longevity.
8. Fehlerbehebung
If you encounter issues with your Multisensor 6, consider the following troubleshooting steps:
- Sensor reagiert nicht: Check battery levels or ensure USB power is connected. Verify the sensor is within range of your Z-Wave gateway.
- Inclusion Failure: Try performing a Z-Wave exclusion (unpairing) on your gateway first, then attempt inclusion again. To exclude, put your gateway into exclusion mode and press the Multisensor 6 Action Button once.
- Ungenaue Messwerte: Ensure the sensor is not exposed to direct sunlight, extreme temperatures, or high humidity if accurate environmental readings are critical. Calibrate sensors if your Z-Wave gateway supports this feature.
- Probleme bei der Bewegungserkennung: Adjust the sensor's position or sensitivity settings via Z-Wave configuration parameters. Ensure no obstructions block the sensor's field of view.
- Z-Wave Network Issues: Perform a network heal or optimize your Z-Wave network through your gateway's interface.
9. Spezifikationen
| Besonderheit | Spezifikation |
|---|---|
| Modellnummer | ZW100 |
| Stromquelle | DC 5V 500mA (Micro USB) or 2 x CR123A batteries |
| Reichweite des Bewegungssensors | 16 feet, 120° field of view |
| Humidity Sensor Range | 20% to 95%, accuracy: ±5% at 77°F (25°C) |
| Temperatursensorbereich | 14°F (-10°C) ~ 140°F (60°C), accuracy: ±0.9°F (0.5°C) |
| Reichweite des Lichtsensors | 0 Lux bis 1000 Lux |
| Vibrationssensor | Acts as tamper switch (ON or OFF) |
| Betriebstemperatur | -4 °F (-20 °C) ~ 140 °F (40 °C) |
| Lagertemperatur | -40 °F (-40 °C) ~ 176 °F (80 °C) |
| Arbeitsfeuchtigkeit | 8 % bis 80 % |
| Betriebsstandort | Drinnen und draußen |
| Maße | 1.8 x 2.5 x 1.8 Zoll |
| Gewicht | 2.08 Unzen (0.13 Pfund) |
10. Garantie und Support
For warranty information, technical support, or further assistance with your Aeotec Multisensor 6, please refer to the official Aeotec webBesuchen Sie die Website oder kontaktieren Sie direkt den Kundendienst. Bewahren Sie Ihren Kaufbeleg für Garantieansprüche auf.