SENCOR SWS 21 S

Sencor SWS 21 S Weather Station User Manual

Model: SWS 21 S

Einführung

Vielen Dank für Ihren Einkauf.asing the Sencor SWS 21 S Weather Station. This device provides accurate indoor and outdoor temperature readings, along with time, date, and alarm functions. Please read this manual carefully before use to ensure proper operation and maintenance.

Sicherheitshinweise

Packungsinhalt

Produkt überview

Hauptgerät

Sencor SWS 21 S Main Unit and Remote Sensor

Bildbeschreibung: The image displays the Sencor SWS 21 S weather station's main unit on the left and its remote sensor on the right. The main unit is black and silver, featuring a large LCD screen that shows time (10:34), date (26/07), indoor temperature (25.0°C), and outdoor temperature (25.6°C). Below the screen are control buttons: 'SET', 'LCD', 'UP/CH', 'DOWN/°C', 'ALARM', and 'SNOOZE'. The remote sensor is white and black, with a smaller display showing 25.6°C and "REMOTE SENSOR" along with a "433MHz" indicator.

  • LCD Anzeige: Shows time, date, indoor/outdoor temperature, and alarm status.
  • Set-Taste: Wechselt in den Einstellungsmodus.
  • LCD-Taste: Adjusts LCD display settings (if applicable).
  • UP/CH Button: Increases values in setting mode or cycles through sensor channels.
  • DOWN/°C Button: Decreases values in setting mode or switches temperature unit (°C/°F).
  • Alarmknopf: Activates/deactivates alarm or enters alarm setting mode.
  • Schlummertaste: Activates snooze function for the alarm.

Drahtloser Fernbedienungssensor

The remote sensor transmits outdoor temperature data to the main unit. It operates on 433 MHz frequency and has a range of up to 30 meters in open areas.

  • Temperatursensor: Measures outdoor temperature.
  • Übertragungsanzeige: Light flashes when transmitting data.
  • Kanalschalter: Allows selection of one of three channels (CH1, CH2, CH3) for multiple sensors.

Aufstellen

1. Einlegen der Batterie

  1. Haupteinheit: Open the battery compartment on the back. Insert 2 x 1.5V AA batteries, observing the correct polarity (+/-). Close the compartment.
  2. Fernbedienungssensor: Open the battery compartment. Insert 2 x 1.5V AAA batteries, observing the correct polarity (+/-). Select a channel (CH1, CH2, or CH3) using the switch inside the compartment. Close the compartment.

2. Sensorkopplung

After inserting batteries into both units, the main unit will automatically search for the remote sensor. The outdoor temperature reading should appear on the main unit's display within a few minutes. If not, press and hold the "UP/CH" button on the main unit to initiate a manual search.

3. Initial Time and Date Setup

The SWS 21 S features a Radio Controlled Clock (RCC) function. It will attempt to synchronize with an atomic clock signal. If synchronization is not immediate or you wish to set it manually:

  1. Halten Sie die SATZ Drücken Sie die Taste so lange, bis die Zeitanzeige blinkt.
  2. Verwenden Sie die UP/CH or DOWN/°C Tasten zum Einstellen der Stunde, dann drücken SATZ zur Bestätigung.
  3. Wiederholen Sie dies für Minuten, Jahr, Monat und Tag.
  4. Drücken SATZ , um den Einstellmodus zu verlassen.

You can also switch between 12/24 hour format during time setting.

Bedienungsanleitung

Zeit- und Datumsanzeige

Temperaturanzeige

Alarmeinstellung

  1. Drücken Sie die ALARM Einmaliges Drücken schaltet die Alarmzeit ein.
  2. Halten Sie die ALARM Drücken Sie die Taste so lange, bis die Alarmzeit blinkt.
  3. Verwenden UP/CH or DOWN/°C Um die Stunde einzustellen, drücken Sie dann ALARM zur Bestätigung.
  4. Wiederholen Sie dies einige Minuten lang. Drücken Sie ALARM , um zu beenden.
  5. Zum Aktivieren/Deaktivieren des Alarms drücken Sie die Taste ALARM button briefly when the alarm time is displayed. An alarm icon will appear/disappear.

Schlummerfunktion

Wenn der Alarm ertönt, drücken Sie die SCHLAFEN Mit dieser Taste lässt sich der Alarm vorübergehend stoppen. Der Alarm ertönt nach etwa 5 Minuten erneut.

Multiple Wireless Sensors (Optional)

The main unit supports up to 3 wireless sensors. If you have multiple sensors, ensure each is set to a different channel (CH1, CH2, CH3) before battery installation. Press the UP/CH button on the main unit to cycle through the outdoor temperature readings from different sensors.

Wartung

Fehlerbehebung

ProblemMögliche UrsacheLösung
Kein Display am HauptgerätDie Batterien sind leer oder falsch eingelegt.Überprüfen Sie die Batteriepolarität oder ersetzen Sie die Batterien.
Die Außentemperatur wird nicht oder falsch angezeigt.Sensor außerhalb der Reichweite, schwacher Batteriestand des Sensors, Störungen oder Sensor nicht gekoppelt.Move sensor closer to main unit. Replace sensor batteries. Avoid placing near electronic devices. Re-initiate sensor search (press and hold UP/CH). Ensure sensor channel matches main unit.
Die Zeit ist falschRCC signal interference or manual setting required.Relocate unit away from electronic devices. Manually set time and date as per "Initial Time and Date Setup" section.
Der Alarm ertönt nichtDer Alarm ist nicht aktiviert.Ensure alarm icon is displayed on the screen.

Technische Daten

BesonderheitDetail
ModellSWS 21 S
Main Unit Dimensions (H x W x D)173 x 75 x 68 mm
Gewicht der Haupteinheit153 g
Remote Sensor Dimensions (H x W x D)95 x 60 x 25 mm
Remote Sensor Weight60 g
Innentemperaturbereich0 °C bis +50 °C
Außentemperaturbereich-20 °C bis +60 °C
Temperaturgenauigkeit±1.5 °C
Drahtlose Frequenz433 MHz
Drahtlose ReichweiteBis zu 30 m (offenes Gelände)
Stromversorgung des Hauptgeräts2 x 1.5 V AA-Batterien
Stromversorgung des Fernsensors2 x 1.5 V AAA-Batterien
UhrentypRadio Controlled Clock (RCC)
Zeitanzeige12/24 Stunden wählbar
AlarmfunktionYes, with Snooze

Garantie und Support

Sencor products are manufactured to high quality standards. For information regarding warranty terms and conditions, or for technical support, please refer to the warranty card included with your product or visit the official Sencor webBewahren Sie Ihren Kaufbeleg als Kaufnachweis auf.

Zugehörige Dokumente - SWS 21 S

Vorview SENCOR SWS 230 Funkuhr – Benutzerhandbuch
User manual for the SENCOR SWS 230 radio-controlled clock. This guide provides detailed instructions on installation, setup, automatic and manual signal reception (DCF), time and alarm settings, temperature monitoring (indoor/outdoor max/min), weather forecasting, time zone selection, and troubleshooting. Learn how to care for your device and dispose of it responsibly.
Vorview SENCOR SWS 2300 Wetterstation Benutzerhandbuch
Ausführliches Benutzerhandbuch für die Wetterstation SENCOR SWS 2300 mit detaillierten Informationen zu Funktionen wie Temperatur- und Feuchtigkeitsüberwachung, Wettervorhersage, Alarmfunktionen und Einrichtungsanweisungen.
Vorview Sencor SWS 5600 Wetterstation – Bedienungsanleitung
Ausführliche Bedienungsanleitung für die Wetterstation Sencor SWS 5600, die Funktionen, Installation, Bedienung und Fehlerbehebung abdeckt.
Vorview SENCOR SWS 5800 User Manual: Digital Alarm Clock with Wireless Charger & Weather Station
Comprehensive user manual for the SENCOR SWS 5800, detailing its features as a digital alarm clock with wireless charging, weather station, temperature and humidity monitoring, and outdoor sensor. Includes setup, operation, safety, and specifications.
Vorview Sencor SWS 8700 Drahtlose Wetterstation – Benutzerhandbuch
Ausführliches Benutzerhandbuch für die drahtlose Wetterstation Sencor SWS 8700. Diese Anleitung behandelt Einrichtung, Bedienung, Funktionen wie Temperatur- und Feuchtigkeitsüberwachung, Wettervorhersage, Alarme, technische Daten und Entsorgungshinweise.
Vorview SENCOR SWS 9300 5-in-1 Drahtlose Wetterstation – Benutzerhandbuch
This user manual provides comprehensive instructions for the SENCOR SWS 9300 wireless weather station. It covers setup, operation, features like indoor/outdoor temperature, humidity, wind speed, wind direction, rainfall, barometric pressure, weather forecasting, and alarm functions. Includes troubleshooting tips, safety precautions, and technical specifications.