Einführung
This manual provides essential information for the safe and effective installation, operation, and maintenance of the Idec RH2B-UL-AC110-120V Electromechanical Relay. Please read this manual thoroughly before using the product to ensure proper function and to prevent potential hazards.
Sicherheitshinweise
WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel. Disconnect all power before working with the relay.
- Always ensure power is disconnected before installation, wiring, or maintenance.
- Überprüfen Sie die korrekte Voltage and current ratings before connecting the relay to a circuit.
- Das Relais darf nicht in Umgebungen betrieben werden, in denen die angegebenen Temperatur- oder Feuchtigkeitsgrenzen überschritten werden.
- Stellen Sie gegebenenfalls eine ordnungsgemäße Erdung sicher.
Produkt überview
The Idec RH2B-UL-AC110-120V is a general-purpose electromechanical relay designed for various industrial control applications. It features a compact design and is suitable for DIN rail mounting.

Figure 1: Idec RH2B-UL-AC110-120V Relays in their original packaging, showing a pack of four units.

Figure 2: A single Idec RH2B-UL-AC110-120V relay, providing an angled view of the transparent casing und interne Komponenten.
Setup und Installation
Follow these steps for proper installation of the Idec RH2B-UL-AC110-120V Relay:
- Stromabschaltung: Ensure all power to the circuit is completely disconnected before beginning installation.
- Montage: The relay is designed for DIN Rail mounting. Securely attach the relay to a standard DIN rail in your control panel.
- Verdrahtung: The relay utilizes through-hole connectors. Carefully connect the control circuit wiring to the coil terminals and the load circuit wiring to the contact terminals. Refer to the wiring diagram (if available in your system documentation) for specific terminal assignments.

Abbildung 3: Unten view of the relay, showing the through-hole connector pins for wiring connections.
- Bandtage Verifizierung: Bestätigen Sie, dass die Liefermengetage for the coil matches the relay's specified voltage von 110–120 V Wechselstrom, 50/60 Hz.

Abbildung 4: Nahaufnahme view of the relay's transparent casing, highlighting the model number and voltage specifications (AC110-120V, 50/60Hz).
- Lastprüfung: Ensure the connected load does not exceed the relay's contact ratings (e.g., 10A resistive at 240VAC).

Abbildung 5: Seite view of the relay, displaying detailed electrical ratings and certifications.
- Endkontrolle: Before restoring power, double-check all connections for security and correctness.
Bedienungsanleitung
The Idec RH2B-UL-AC110-120V Relay operates automatically based on the control signal applied to its coil. When the specified AC voltage (110-120V) is applied to the coil, the relay contacts will switch, opening or closing the connected load circuit. When the voltage is removed, the contacts return to their original state.
- Ensure the control signal is within the specified voltage-Bereich für zuverlässigen Betrieb.
- Observe any indicator lights on the relay (if present) to confirm coil energization.
Wartung
The Idec RH2B-UL-AC110-120V Relay is designed for long-term, reliable operation with minimal maintenance. However, periodic inspection is recommended:
- Sichtprüfung: Periodically check the relay for any signs of physical damage, discoloration, or loose connections.
- Reinigung: Reinigen Sie das Relais bei Bedarf vorsichtig mit einem trockenen, weichen Tuch. Verwenden Sie keine Lösungsmittel oder Scheuermittel.
- Kontaktinspektion: In critical applications, inspect contacts for pitting or wear. Replace the relay if significant wear is observed.
- Umgebungsbedingungen: Um vorzeitige Ausfälle zu vermeiden, muss sichergestellt werden, dass die Betriebsumgebung innerhalb der vorgegebenen Temperatur- und Feuchtigkeitsbereiche bleibt.
Fehlerbehebung
Falls das Relais nicht wie erwartet funktioniert, sollten Sie folgende häufige Fehlerquellen in Betracht ziehen:
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Die Relaisspule wird nicht erregt. | Keine Spannung an der Spule, falsche Spannungtage, faulty wiring, or damaged coil. | Netzteil prüfen, Spannung prüfentage (110-120V AC), inspect wiring connections, test coil continuity. |
| Contacts do not switch. | Coil not energizing, contacts welded, or mechanical failure. | Refer to "Relay coil does not energize" solutions. If coil is good, replace relay. |
| Load not receiving power. | Relay contacts not closing, open circuit in load wiring, or faulty load. | Verify relay operation. Check load circuit wiring and the load itself. |
If troubleshooting steps do not resolve the issue, contact Idec technical support or a qualified electrician.
Technische Daten
| Parameter | Wert |
|---|---|
| Modellnummer | RH2B-UL-AC110-120V |
| Marke | Idec |
| Spule Voltage | 110-120V AC |
| Frequenz | 50/60 Hz |
| Current Rating (Resistive) | 10A @ 240VAC, 10A @ 30VDC |
| Current Rating (General Use) | 7.5A @ 120VAC, 7A @ 240VAC, 7.5A @ 30VDC |
| PS-Bewertung | 1/6 HP @ 120VAC, 1/3 HP @ 240VAC |
| Montagetyp | DIN-Schienenmontage |
| Steckertyp | Durchgangsloch |
| Betriebsmodus | Automatisch |
| Artikelgewicht | 0.01 Unzen |
| Hersteller | Idec |
Garantie und Support
For warranty information and technical support, please contact Idec directly through their official webWebsite oder Kundendienstkanäle. Bewahren Sie Ihren Kaufbeleg für Garantieansprüche auf.
Idec Official WebWebsite: us.idec.com