Einführung
Thank you for choosing the Taylor Digital Indoor/Outdoor Thermometer. This versatile device provides accurate temperature readings for both indoor and outdoor environments. Featuring a reversible suction cup for flexible mounting and an easy-to-read LCD display, it tracks temperatures in both Fahrenheit and Celsius, including daily minimum and maximum readings.

Image: The Taylor Digital Indoor/Outdoor Thermometer, a compact black device with a clear LCD screen, designed for versatile temperature monitoring.
Sicherheitshinweise
- Do not expose the thermometer to extreme temperatures beyond its operating range (-4°F to 140°F / -20°C to 60°C).
- While weather-resistant, avoid direct exposure to heavy rain, snow, or prolonged direct sunlight to ensure longevity and accuracy.
- Bewahren Sie Batterien außerhalb der Reichweite von Kindern auf. Bei Verschlucken sofort einen Arzt aufsuchen.
- Entsorgen Sie gebrauchte Batterien gemäß den örtlichen Vorschriften.
- Versuchen Sie nicht, das Gerät zu zerlegen oder zu reparieren. Wenden Sie sich an den Kundendienst.
Packungsinhalt
- 1 x Taylor Digital Indoor/Outdoor Thermometer (Model 1700)
- 1 x LR44 Batterie (vorinstalliert oder separat enthalten)
Produkteigenschaften
- Verwendung im Innen- und Außenbereich: Designed for versatile placement.
- Großer Temperaturbereich: Messbereich: -4°F bis 140°F (-20°C bis 60°C).
- Reversible Suction Cup: Allows for easy mounting on windows or smooth surfaces, facing either inward or outward.
- Minimal-/Maximaltemperaturaufzeichnung: Automatically records the highest and lowest temperatures over a 24-hour period.
- Klares LCD-Display: Features oversized digits for enhanced readability.
- Batteriebetrieben: Requires 1 LR44 battery (included).
Aufstellen
1. Einlegen der Batterie
- Suchen Sie das Batteriefach auf der Rückseite des Thermometers.
- Öffnen Sie die Abdeckung des Batteriefachs.
- Insert one LR44 battery, ensuring the correct polarity (+/-) as indicated inside the compartment.
- Close the battery compartment cover securely. The display should activate.
2. Mounting the Thermometer
The thermometer features a reversible suction cup for flexible mounting.
- For Indoor Reading of Outdoor Temperature: Attach the suction cup to the outside of a clean window, with the display facing inward.
- For Outdoor Reading: Attach the suction cup to the inside of a clean window, with the display facing outward.
- Ensure the surface is clean and dry for optimal suction. Press firmly to secure.
- For best accuracy, place the thermometer in a shaded area, away from direct sunlight, which can cause elevated readings.
Bedienungsanleitung
1. Ablesen der Temperatur
Once the battery is installed, the current temperature will be displayed on the LCD screen. The large digits ensure easy readability.
2. Umschalten der Temperatureinheiten (°F/°C)
Locate the small button on the back or side of the thermometer, usually labeled "°F/°C". Press this button to toggle between Fahrenheit and Celsius temperature displays.
3. Viewing and Resetting Min/Max Temperatures
The thermometer automatically records the minimum and maximum temperatures reached since the last reset.
- Zu view the minimum temperature, press the "MIN" button (if available, or a multi-function button).
- Zu view the maximum temperature, press the "MAX" button (if available, or a multi-function button).
- To reset the Min/Max readings, press and hold the "RESET" button (or the Min/Max button for a few seconds) until the display clears or resets. The 24-hour period for Min/Max tracking begins from the time of the last reset.
Wartung
- Reinigung: Wischen Sie das Thermometer mit einem weichen,amp Mit einem Tuch abwischen. Keine Scheuermittel verwenden und das Gerät nicht in Wasser tauchen.
- Batteriewechsel: When the display becomes dim or stops functioning, replace the LR44 battery as described in the "Battery Installation" section.
- Lagerung: If storing the thermometer for an extended period, remove the battery to prevent leakage.
Fehlerbehebung
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Das Display ist leer oder dunkel. | Schwache oder leere Batterie; falsche Batterieinstallation. | Tauschen Sie die LR44-Batterie aus und achten Sie dabei auf die richtige Polarität. |
| Ungenaue Temperaturmessungen. | Direct sunlight exposure; proximity to heat/cold sources; unit not calibrated (unlikely for this model). | Relocate the thermometer to a shaded area. Ensure it is not near vents, windows with direct sun, or other appliances that emit heat/cold. Allow time for the unit to stabilize. |
| Der Saugnapf hält nicht. | Surface is dirty, wet, or not smooth; suction cup is damaged. | Clean and dry the mounting surface thoroughly. Ensure the suction cup is clean. If damaged, it may need replacement. |
| Display goes blank in very cold weather. | Temperature is below the operating range of the LCD. | This is normal for some LCDs in extreme cold. The display should return when temperatures rise within the operating range. The internal sensor may still be functioning. |
Technische Daten
| Modellnummer | 1700 |
| Temperaturbereich | -4°F bis 140°F (-20°C bis 60°C) |
| Stromquelle | 1 x LR44 Battery (included) |
| Anzeigetyp | LCD |
| Material | Plastik |
| Abmessungen (ca.) | 5 Zoll (Länge) |
| Gewicht (ca.) | 1.41 Unzen |
| Verwendung im Innen- und Außenbereich | Ja |
Garantie und Support
This Taylor Digital Indoor/Outdoor Thermometer (Model 1700) comes with a 1 Jahr eingeschränkte Garantie from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage resulting from misuse, accident, unauthorized service, or other causes not arising from defects in material or workmanship.
For warranty claims, technical support, or general inquiries, please visit the official Taylor webWebsite oder wenden Sie sich an die Kundendienstabteilung.
Online-Hilfe: Visit the Taylor Store on Amazon