The Gallagher W310 v2 Automatic Weigh Scale is an entry-level device designed for efficient and accurate livestock weighing. It features basic two-way drafting capability and seamless integration with the HR5 Hand Held EID Tag Reader. This manual provides comprehensive instructions for setting up, operating, and maintaining your W310 v2 weigh scale to ensure optimal performance and longevity.

Gallagher W310 v2 Automatic Weigh Scale

Figure 1: The Gallagher W310 v2 Automatic Weigh Scale, shown in its open position, displaying the screen and control buttons.

Hauptmerkmale:

Setup und Installation

Proper setup is crucial for accurate and reliable operation of your Gallagher W310 v2 Weigh Scale. Follow these steps carefully:

  1. Auspacken: Carefully remove the weigh scale from its packaging. Inspect for any signs of damage. Retain packaging for future transport or storage.
  2. Laden des Akkus: The W310 v2 has an internal rechargeable battery. Before first use, fully charge the unit using the provided AC adapter. Connect the adapter to the charging port on the scale and plug it into a suitable power outlet. The charge indicator on the display will show charging status.
  3. Connecting Load Bars: The W310 v2 is designed for use with Gallagher load bars (sold separately). Connect the load bar cables to the appropriate ports on the weigh scale. Ensure connections are secure.
  4. Mounting the Scale: Mount the weigh scale in a secure, stable location, typically near the weighing platform or crush. Ensure it is protected from direct impact and excessive moisture, although it features a water-resistant case.
  5. Erstes Einschalten: Press and hold the power button to turn on the scale. The display will illuminate, and the system will perform a self-check.
  6. Anschluss externer Geräte (optional):
    • HR5 Hand Held EID Tag Leser: To connect via Bluetooth, ensure the Bluetooth adapter is powered from the weigh scale. Follow the pairing instructions for your HR5 reader to establish a connection.
    • Computer/Printer: Use the inbuilt communication port (serial or USB, depending on model/adapter) to connect to a computer or printer for data transfer. Refer to your computer's or printer's manual for specific connection details.
Gallagher W310 v2 Weigh Scale installed in a livestock handling system

Figure 2: The Gallagher W310 v2 Weigh Scale mounted and in operation within a livestock handling system, demonstrating a typical installation.

Bedienungsanleitung

The W310 v2 offers multiple weighing modes to suit different operational needs. Familiarize yourself with the controls and modes for efficient weighing.

Kontrollen überview:

Weighing Modes:

Rotate the selector knob to choose your desired weighing mode:

  1. Auto-weighing Mode:

    In this mode, the animal's weight locks automatically once stable, allowing for fast, hands-free weighing. This is ideal for high-throughput operations.

    • Ensure the scale is zeroed before an animal enters the platform.
    • Once the animal is on the platform, the scale will detect its presence and automatically lock onto a stable weight.
    • The locked weight will be displayed and can be recorded or sent to connected devices.
  2. Manual Weighing Mode:

    This mode gives the operator full control over the weighing cycle. The weight is recorded only when the WEIGH key is pressed.

    • Place the animal on the platform.
    • Wait for the animal to settle.
    • Drücken Sie die WIEGEN key to capture and record the weight.
  3. Fine Weighing Mode:

    Designed for small load weighing, this mode operates with no zero tracking for greater accuracy. It is suitable for precise measurements where minimal movement is expected.

    • Ensure the platform is clear and stable.
    • Place the item to be weighed carefully on the platform.
    • The scale will display the precise weight.

Datenverwaltung:

Gallagher W310 v2 Weigh Scale with feature callouts

Abbildung 3: Ausführlich view of the Gallagher W310 v2 Weigh Scale highlighting its key features, including built-in Bluetooth connectivity, multiple weighing modes, and the large display.

Wartung

Regular maintenance ensures the longevity and accuracy of your Gallagher W310 v2 Weigh Scale.

Fehlerbehebung

This section provides solutions to common issues you might encounter with your W310 v2 Weigh Scale.

ProblemMögliche UrsacheLösung
Die Waage lässt sich nicht einschalten.Battery is fully discharged or faulty.Connect the AC adapter and charge the unit. If it still doesn't turn on, the battery may need replacement or contact support.
Ungenaue Gewichtsmessungen.Load bars not properly connected or damaged; scale not zeroed; unstable weighing platform.Ensure load bars are securely connected. Press the ZERO key before weighing. Verify the weighing platform is stable and level.
Cannot connect to HR5 Reader via Bluetooth.Bluetooth adapter not powered; incorrect pairing procedure; interference.Ensure the Bluetooth adapter is powered. Re-attempt pairing following instructions for both devices. Reduce interference by moving closer to the HR5 reader.
Das Display ist dunkel oder flackert.Low battery; extreme temperatures.Recharge the battery. Operate the scale within its specified temperature range.

If you encounter issues not listed here or if the suggested solutions do not resolve the problem, please contact Gallagher customer support.

Technische Daten

BesonderheitDetail
HerstellerGallagher
Teilenummer13053
Technische Daten23.5 x 21.5 x 9.5 cm
Artikelgewicht3.4 kg
FarbeOrange
AnzeigestilLCD
Besondere MerkmaleBacklit Display, Internal Rechargeable Battery, Bluetooth Connectivity (via adapter)
StromquelleInternal Rechargeable Battery / AC Adapter
Erstes verfügbares Datum11. Februar 2020

Garantie und Support

The Gallagher W310 v2 Automatic Weigh Scale comes with a ein Jahr Garantie ab Kaufdatum. Diese Garantie deckt Material- und Verarbeitungsfehler bei normalem Gebrauch ab.

For warranty claims, technical support, or further assistance, please contact Gallagher customer service. You can typically find contact information on the official Gallagher webWebsite oder über Ihren lokalen Händler.

Bitte halten Sie Ihre Produktmodellnummer (13053) und den Kaufbeleg bereit, wenn Sie sich an den Support wenden.

Zugehörige Dokumente - 13053

Vorview Gallagher Animal Performance – Kurzanleitung: Einrichtung, Updates und Synchronisierung
Starten Sie schnell mit dem Gallagher Animal Performance System. Diese Anleitung behandelt die Kontoeinrichtung, den App-Download und Hardware-Updates für TW Weigh Scales und HR Hand Held EID Tag Leser und Datensynchronisierung.
Vorview Gallagher TW-1 Waage – Kurzanleitung
Diese Kurzanleitung enthält wichtige Informationen für die Einrichtung und Verwendung der Gallagher TW-1 Waage, einschließlich Lieferumfang, Spezifikationen, Installation und grundlegender Bedienung.
Vorview Gallagher TW-1 Waage – Kurzanleitung
Nehmen Sie Ihre Gallagher TW-1 Tierwaage in Betrieb. Diese Anleitung enthält alle wichtigen Hinweise zur Einrichtung, Bedienung und Wartung dieser Viehwaage. Registrieren Sie sich online für eine Garantieverlängerung.
Vorview Gallagher W-0 Waage – Benutzerhandbuch
Ausführliche Bedienungsanleitung für die Gallagher W-0 Tierwaage mit detaillierten Informationen zu Einrichtung, Bedienung, Installation, Pflege und Integration in mobile Apps für die Viehverwiegung.
Vorview Gallagher Animal Performance Schnellstartanleitung
Eine Kurzanleitung für die Einrichtung und Verwendung des Gallagher Animal Performance Systems, einschließlich der TW-Waage und des HR Hand-EID-Geräts. Tag Leser.
Vorview Gallagher HRO Hand Held EID Tag Leser-Benutzerhandbuch
User manual for the Gallagher HRO Hand Held EID Tag Reader, detailing its features, operation, connectivity, care, specifications, and troubleshooting. This device uses Bluetooth® wireless technology to read animal Electronic Identification (EID) tags and connect to recording devices like weigh scales or mobile apps.