1. Einleitung
This manual provides essential instructions for the safe installation, operation, and maintenance of your BEST LEDR-1 LED Emergency Light. Please read this manual thoroughly before installation and retain it for future reference. The LEDR-1 is designed to provide reliable emergency illumination during power outages, ensuring safety in commercial and residential environments.
2. Wichtige Sicherheitshinweise
WARNUNG: Stromschlaggefahr. Vor Installation oder Wartung die Stromzufuhr unterbrechen.
- Sämtliche Wartungsarbeiten sollten nur von qualifiziertem Personal durchgeführt werden.
- Nicht in der Nähe von Gas- oder Elektroheizungen montieren.
- Ensure the electrical wiring is properly grounded.
- Nicht im Freien verwenden. Dieses Gerät ist ausschließlich für den Innenbereich bestimmt.
- Achten Sie darauf, dass das Netzkabel keine heißen Oberflächen berührt.
- Mount the unit in locations and at heights where it will not be subjected to tampBedienung durch unbefugtes Personal.
- Die Verwendung von Zusatzgeräten, die vom Hersteller nicht empfohlen werden, kann zu Sicherheitsproblemen führen.
- Verwenden Sie dieses Gerät nur für den vorgesehenen Zweck.
- Allow battery to charge for a minimum of 24 hours after installation before testing.
3. Packungsinhalt
Prüfen Sie beim Öffnen der Verpackung, ob alle Komponenten vorhanden und unbeschädigt sind:
- BEST LEDR-1 LED Emergency Light Fixture (1 unit)
- Montagezubehör (Schrauben, Dübel)
- Drahtmuttern
- Benutzerhandbuch (dieses Dokument)
- AA NiCAD Battery (pre-installed or included separately)
4. Produktüberschreitungview
The BEST LEDR-1 is a compact and efficient LED emergency light designed for wall-mount applications. It features a durable white thermoplastic housing and two adjustable LED lamp heads, providing 98 lumens of bright, white light (5000 Kelvin) during emergency situations. The unit operates on 120 Volts AC and includes a rechargeable NiCAD battery for backup power.

Abbildung 1: Vorderseite view of the BEST LEDR-1 Emergency Light. This image shows the compact white thermoplastic housing with two adjustable LED lamp Köpfe.
Hauptmerkmale:
- Gehäuse: White Thermoplastic
- Lichtquelle: 2 LED heads
- Bandtage: 120 Volt AC
- Batterie: NiCAD, 90 minutes average life
- Lichtleistung: 98 Lumen
- Abmessungen: Ungefähr 14.75 cm L x 3.75 cm B x 3.75 cm H
5. Installation
The LEDR-1 is designed for flush wall mounting. Follow these steps for proper installation:
- Stromabschaltung: Before beginning any installation, ensure that the main power supply to the circuit where the emergency light will be installed is turned OFF at the circuit breaker or fuse box.
- Montageort: Select a suitable wall location for mounting. The unit should be mounted at a height and in a position that allows for optimal light distribution during an emergency. Ensure the mounting surface is solid and can support the fixture's weight.
- Montagefläche vorbereiten: Use the provided mounting hardware (screws and anchors) to secure the mounting plate or backplate of the emergency light to the wall. If the unit has a separate mounting plate, attach it first.
- Kabelverbindungen:
- Verbinden Sie schwarzes Kabel from the emergency light to the hot (live) wire from the building's electrical supply.
- Verbinden Sie weißer Draht from the emergency light to the Neutralleiter from the building's electrical supply.
- Verbinden Sie grünes Kabel from the emergency light to the Erdungskabel from the building's electrical supply.
- Verwenden Sie die mitgelieferten Drahtklemmen, um alle Verbindungen zu sichern. Achten Sie darauf, dass alle Verbindungen fest sitzen und ordnungsgemäß isoliert sind.
- Batterieanschluss: If the battery is not pre-connected, connect the battery pack to the circuit board. Ensure correct polarity.
- Sichere Befestigung: Carefully tuck all wires into the junction box or fixture housing. Secure the emergency light fixture to the mounting plate or wall according to the specific design of the unit.
- Strom wiederherstellen: Once the installation is complete and all connections are secure, restore power to the circuit. The CHARGE INDICATOR light on the unit should illuminate, indicating that the battery is charging.
- Grundgebühr: Allow the battery to charge for a minimum of 24 hours before performing the first test.
6. Bedienung
The BEST LEDR-1 Emergency Light operates automatically:
- Wechselstrom ein: When AC power is supplied to the unit, the charge indicator light will be ON, and the battery will be charging. The LED lamp heads will remain OFF.
- Macht Outage: In the event of an AC power failure, the emergency light will automatically switch to battery backup mode, and the LED lamp heads will illuminate. The unit will provide emergency lighting for approximately 90 minutes.
- AC Power Restored: When AC power is restored, the LED lamp heads will turn OFF, and the unit will revert to charging the battery.
- Test-Taste: A test button is located on the unit. Pressing this button simulates an AC power failure, allowing you to verify that the emergency lights function correctly. Release the button to return to normal operation.
- Einstellbares Lamp Köpfe: Die beiden LED lamp heads can be manually adjusted to direct light to desired areas.
7. Wartung
Regular maintenance ensures the longevity and reliability of your emergency light.
Batterietest:
Perform the following tests according to local codes and regulations (typically monthly and annually):
- Monatlicher Test: Press and hold the test button for at least 30 seconds. The LED lamp heads should illuminate. Release the button; the lights should turn off, and the charge indicator should be ON.
- Jährlicher Test: Disconnect AC power to the unit for a full 90 minutes. The LED lamp heads should remain illuminated for the entire duration. Reconnect AC power; the lights should turn off, and the charge indicator should be ON. If the unit fails to operate for the full 90 minutes, the battery may need replacement.
Reinigung:
Clean the exterior of the unit and lamp heads periodically with a soft, damp Tuch. Keine Scheuer- oder Lösungsmittel verwenden.
Batteriewechsel:
The NiCAD battery has a limited lifespan. If the unit fails the annual 90-minute test, the battery likely needs replacement. Contact a qualified electrician or the manufacturer for battery replacement instructions and compatible battery types.
8. Fehlerbehebung
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Emergency lights do not turn ON during power outage or when test button is pressed. |
|
|
| Charge indicator light is OFF when AC power is present. |
|
|
| Emergency lights do not stay ON for 90 minutes during annual test. |
|
|
9. Spezifikationen
| Besonderheit | Detail |
|---|---|
| Modellnummer | LEDR-1 |
| Marke | AM BESTEN |
| Gehäusematerial | White Thermoplastic |
| Lichtquellentyp | LED (2 heads) |
| Bandtage | 120 Volt AC |
| Wastage | 2 Watt |
| Helligkeit | 98 Lumen |
| Effizienz | 49 Lumen/Watt |
| Farbtemperatur | 5000 Kelvin |
| Akku-Typ | NiCAD (1 AA battery required, included) |
| Average Battery Life (Emergency Mode) | 90 Мinuten |
| Installationstyp | Bündige Wandhalterung |
| Verwendung im Innen- und Außenbereich | Nur für den Innenbereich |
| Produktabmessungen (L x B x H) | 14.75" x 3.75" x 3.75" |
| Artikelgewicht | 0.01 Unzen |
| Kontrollmethode | Remote (Test Button) |
10. Garantie und Support
The BEST LEDR-1 LED Emergency Light comes with a full manufacturer warranty. For specific warranty details, claims, or technical support, please refer to the warranty card included with your product or contact Best Lighting Products directly. Keep your purchase receipt as proof of purchase.