1. Einleitung
The ACI A/100KS-D-4"-PB Duct Temperature Sensor is a precision instrument designed for accurate temperature measurement within HVAC, building automation, and light industrial systems. This sensor utilizes a 100k ohm thermistor at 77°F (25°C) to provide reliable temperature data. Its robust design includes a plastic duct mount configuration with a mounting flange for easy installation and a foam pad to minimize vibration. The sensing element is double encapsulated to prevent moisture infiltration, ensuring long-term performance and reliability.
Typical applications for this sensor include zone control, air handling units, and general temperature monitoring within ductwork environments.
2. Sicherheitshinweise
Please read all instructions carefully before installation and operation. Failure to follow these instructions may result in equipment damage or personal injury.
- Disconnect all power to the system before installation or maintenance.
- Die Installation sollte von qualifiziertem Fachpersonal unter Einhaltung aller lokalen und nationalen Elektrovorschriften durchgeführt werden.
- Do not exceed the specified operating temperature or humidity ranges.
- Avoid exposing the sensor to corrosive chemicals or excessive mechanical stress.
- Sorgen Sie für eine ordnungsgemäße Erdung, um elektrische Gefahren zu vermeiden.
3. Komponenten und Packungsinhalt
Vergewissern Sie sich vor Beginn der Installation, dass alle Komponenten vorhanden und unbeschädigt sind.
- ACI A/100KS-D-4"-PB Duct Temperature Sensor (with integrated plastic enclosure and 4-inch probe)
- Mounting Screws (typically included, verify with packaging)

Figure 3.1: ACI A/100KS-D-4"-PB Duct Temperature Sensor. This image shows the ACI A/100KS-D-4"-PB Duct Temperature Sensor. It features a black plastic enclosure with a metal temperature probe extending upwards. The enclosure has a mounting flange and visible knockouts for wiring.
4. Einrichtung und Installation
The ACI duct temperature sensor is designed for straightforward installation in ductwork.
4.1. Standortauswahl
- Choose a location in the ductwork that provides a representative temperature reading of the air stream. Avoid areas directly downstream of coils, fans, or other heat sources/sinks that could skew readings.
- Ensure sufficient clearance for mounting the plastic enclosure and inserting the probe into the duct.
4.2. Montage
- Drill a hole in the ductwork large enough to accommodate the 4-inch sensor probe.
- Position the sensor's mounting flange against the duct surface. The integrated foam pad on the enclosure helps dampen vibrations and provides a seal.
- Secure the enclosure to the duct using appropriate screws through the mounting holes on the flange.
4.3. Verkabelung
- Open the plastic enclosure.
- Route the necessary wiring through one of the knockouts provided on the enclosure.
- Connect the sensor wires to your building automation system or controller according to the system's wiring diagram. Refer to the specifications section for thermistor resistance values.
- Stellen Sie sicher, dass alle Verbindungen sicher und isoliert sind.
- Close the enclosure securely after wiring is complete.
5. Funktionsprinzipien
The A/100KS-D-4"-PB sensor operates on the principle of thermistor resistance change with temperature. A thermistor is a type of resistor whose resistance is strongly dependent on temperature, more so than in standard resistors. As the ambient air temperature within the duct changes, the resistance of the 100k ohm thermistor element changes accordingly. Your building automation system or controller measures this resistance change and converts it into a temperature reading.
The double-encapsulated sensing element ensures that the thermistor remains protected from moisture, which is crucial for maintaining accuracy and longevity in duct environments.
6. Wartung
The ACI Duct Temperature Sensor is designed for minimal maintenance. However, periodic checks can ensure optimal performance.
- Jährliche Inspektion: Annually inspect the sensor and its wiring for any signs of physical damage, corrosion, or loose connections.
- Reinigung: If dust or debris accumulates on the probe or enclosure, gently wipe it clean with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Neukalibrierung: While these sensors are generally stable, if significant discrepancies in temperature readings are observed, consult your building automation system's documentation for recalibration procedures or consider professional service.
7. Fehlerbehebung
Dieser Abschnitt bietet Lösungen für häufig auftretende Probleme.
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| No temperature reading or incorrect reading. | Wackelkontakt. Sensor damaged. Incorrect wiring to controller. Controller input misconfigured. | Überprüfen Sie alle Kabelverbindungen auf festen Sitz. Inspect sensor for physical damage. If damaged, replace. Verify wiring against controller's specifications. Confirm controller input is set for a 100k ohm thermistor. |
| Temperature reading is consistently high/low. | Sensor located in an unrepresentative area. Calibration offset in controller. Sensor aging. | Relocate sensor to a more appropriate position in the duct. Check controller settings for any applied offsets and adjust if necessary. If sensor is old, consider replacement. |
| Intermittent readings. | Wackelkontakt. Interferenz. Moisture ingress (unlikely due to encapsulation). | Überprüfen und sichern Sie alle Kabelverbindungen. Ensure wiring is routed away from sources of electrical interference. Inspect enclosure for signs of damage that could allow moisture. |
8. Spezifikationen
| Attribut | Wert |
|---|---|
| Modell | A/100KS-D-4"-PB |
| Marke | ACI (Automation Components Inc.) |
| Sensortyp | Thermistoren |
| Widerstand | 100k ohms @ 77°F (25°C) |
| Sondenlänge | 4 Zoll |
| Gehäusematerial | Plastik |
| Montage | Duct Mount with Flange |
| Besondere Merkmale | Foam pad for vibration dampening, Double encapsulated sensing element |
| ASIN | B01M0V9CEK |
| Datum der ersten Verfügbarkeit | 22. September 2016 |
9. Garantie und Support
For specific warranty information, please refer to the documentation provided with your purchase or visit the official ACI website. ACI products are typically covered by a manufacturer's warranty against defects in materials and workmanship.
For technical support, troubleshooting assistance beyond this manual, or to inquire about replacement parts, please contact ACI customer service or your authorized distributor. Contact information can usually be found on the manufacturer's webauf der Website oder auf Ihrer Kaufrechnung.
Hersteller: Automation Components Inc. (ACI)
WebWebsite: www.workaci.com (Examp(Link, offizielle Website überprüfen)