Alphacool 13305

Alphacool Eispumpe VPP755 mit Eisdecke D5 V.3 Pump/Res Combo Bedienungsanleitung

Modell: 13305

1. Einleitung

This manual provides essential information for the proper installation, operation, and maintenance of your Alphacool Eispumpe VPP755 with Eisdecke D5 V.3 Pump/Res Combo. Please read this manual thoroughly before beginning installation to ensure safe and efficient use of the product.

Alphacool Eispumpe VPP755 with Eisdecke D5 V.3 Pump/Res Combo

Figure 1: Alphacool Eispumpe VPP755 with Eisdecke D5 V.3 Pump/Res Combo, showing the pump unit integrated into the acetal reservoir top.

2. Sicherheitshinweise

  • Flüssigkeitskompatibilität: Use only clear, transparent water cooling fluids. Fluids containing particles or additives (e.g., Pastel fluids) can clog and permanently damage water cooling components such as radiators, pumps, and blocks. Use of such fluids may void the manufacturer's warranty.
  • Impeller Handling: Removing the impeller from the ceramic shaft will cause the upper ceramic clamping ring to over-expand, leading to its destruction. This action will void the pump's warranty. If the pump is reassembled after such removal, the clamping ring will loosen, which is not accepted as grounds for return or exchange.
  • Bandtage: Stellen Sie sicher, dass die Stromversorgungslautstärketage is within the permitted range of 8-13V DC.
  • Temperatur: Do not exceed the maximum system temperature of 65°C.

3. Packungsinhalt

Im Lieferumfang sind folgende Artikel enthalten:

  • 1x Alphacool Eispumpe VPP755 - G1/4 IT
  • 1x Eisdecke D5 - Acetal V.3

4. Einrichtung und Installation

4.1 Physische Installation

The pump/res combo can be mounted using the integrated brackets. Ensure stable placement within your system to prevent vibration and stress on connections.

Alphacool Eispumpe VPP755 with Eisdecke D5 V.3 Pump/Res Combo with mounting brackets

Abbildung 2: Seite view of the pump/res combo, illustrating the mounting brackets for secure installation.

4.2 Port-Anschlüsse

The Eisdecke D5 V.3 features multiple G1/4" threads for flexible integration into your water cooling loop. Identify the IN (inlet) and OUT (outlet) ports as labeled on the unit for correct flow direction.

Spitze view of Alphacool Eisdecke D5 V.3 showing G1/4 inch ports

Abbildung 3: Oben view of the Eisdecke D5 V.3, highlighting the G1/4" inlet (IN) and outlet (OUT) ports for tubing connections.

4.3 Elektrische Anschlüsse

Connect the pump to your power supply and motherboard using the provided cables:

  • 4-pin Molex: For main power supply to the pump.
  • 3-pin Tach Signal: Connect to a motherboard fan header to monitor pump RPM.
  • 4-pin PWM Signal: Connect to a motherboard PWM fan header for speed control.
Alphacool Eispumpe VPP755 power and signal cables

Figure 4: The power and signal cables for the VPP755 pump, including the 4-pin Molex, 3-pin tachometer, and 4-pin PWM connectors.

5. Bedienungsanleitung

The Alphacool Eispumpe VPP755 features an adjustable speed setting, allowing you to optimize performance and noise levels for your specific cooling needs.

5.1 Einstellbare Stufen

The pump can be adjusted in five distinct levels, controlling the rotational speed (RPM):

  • Stufe 1: 1800 U/min
  • Stufe 2: 2500 U/min
  • Stufe 3: 3200 U/min
  • Stufe 4: 3900 U/min
  • Stufe 5: 4500 U/min

Adjust the level according to your system's cooling requirements and desired noise profile. Higher levels provide greater flow rate and pressure.

6. Wartung

Regular maintenance is crucial for the longevity and performance of your water cooling system. Ensure to use only clear, transparent water cooling fluids. Avoid fluids with particles or additives, as they can cause blockages and damage to the pump and other components. Periodically inspect your loop for any signs of debris or fluid discoloration.

7. Fehlerbehebung

If you experience issues with your pump, consider the following:

  • No Power/No Operation: Check all electrical connections (4-pin Molex, 3-pin tach, 4-pin PWM) to ensure they are securely seated and receiving power. Verify your power supply is functioning correctly.
  • Reduced Flow/Noise: This could indicate air in the loop or a blockage. Bleed the system thoroughly to remove air. If using non-compatible fluids, a blockage may have occurred.
  • Impeller Issues: As stated in the safety information, do not attempt to remove the impeller from the ceramic shaft. Doing so will damage the clamping ring and void the warranty. If the pump exhibits unusual noises or performance issues after unauthorized disassembly, it is likely damaged beyond repair and not covered by warranty.

8. Technische Daten

8.1 VPP755 Eispumpe

BesonderheitSpezifikation
Abmessungen (T x H)60 x 53.5 mm
Kabellänge50 cm
Standardvolumentage12 V Gleichstrom
Energieaufnahme14 W
Permitted Voltage8-13V DC
Pressure at 12V4m water head
Maximaler Durchfluss350l/h
Pump MediumWater, water/glycol mixture
Maximum System Temperature65°C
Stromanschluss4-poliger Molex
Tach Signal3-polig
PWM-Signal4-polig
Einstellbare Pegel5 Stufen (1800-4500 U/min)

8.2 Eisdecke D5 V.3

BesonderheitSpezifikation
Maße80 x 80 x 40 mm
Dimensions with Stands83 x 80 x 87 mm
MaterialAcetal
Anschlüsse5x 1/4" threads
Dimensional drawing of Alphacool Eispumpe VPP755 with Eisdecke D5 V.3

Figure 5: Dimensional drawing of the Alphacool Eispumpe VPP755 with Eisdecke D5 V.3, showing key measurements for integration.

9. Garantie und Support

The manufacturer's warranty for the Alphacool Eispumpe VPP755 with Eisdecke D5 V.3 Pump/Res Combo is subject to specific conditions. Please note the following:

  • Ausbau des Laufrads: Any attempt to remove the impeller from the ceramic shaft will result in damage to the internal clamping ring and will immediately void the pump's warranty.
  • Flüssigkeitsverbrauch: Use of non-compatible fluids, particularly those containing particles or additives (e.g., Pastel fluids), can cause permanent damage to the pump and other water cooling components, potentially voiding the manufacturer's warranty.

For technical support or warranty inquiries, please refer to the official Alphacool website or contact their customer service directly. Always provide your product model number (13305) and proof of purchase when seeking support.

Zugehörige Dokumente - 13305

Vorview Alphacool EisPumpe-VPP755 Wasserkühlungspumpe: Installations-, Betriebs- und Sicherheitshinweise
Ausführlicher Leitfaden für die Alphacool EisPumpe-VPP755 Wasserkühlungspumpe, der Installation, elektrische Anschlüsse, manuelle und PWM-Drehzahlregelung, technische Daten, Sicherheitshinweise und Garantiebedingungen umfasst.
Vorview Alphacool Core Flat Reservoir 240 rechts mit VPP-Pumpe – Technische Daten
Entdecken Sie den Alphacool Core Flat Reservoir 240 Right mit integrierter VPP-Pumpe, digitaler aRGB-Beleuchtung und flachem Acryl-Design – ideal für individuelle PC-Wasserkühlungen und kompakte Systeme. Fünf Anschlüsse ermöglichen flexible Konfigurationen.
Vorview Alphacool Eisdecke Pump Top Installation and Technical Details
Comprehensive guide to the Alphacool Eisdecke pump top, covering installation, technical specifications, and safety instructions in multiple languages.
Vorview Alphacool Rise Flat Reservoir Installation Guide
Comprehensive guide for installing the Alphacool Rise Flat Reservoir with DDC, D5, and VPP pumps. Includes parts list, assembly instructions for case and radiator mounting, fill port usage, tube assembly, and digital RGB integration.
Vorview Alphacool ES 4U Reservoir with D5 Top Installation Guide
Comprehensive installation guide for the Alphacool ES 4U Reservoir with D5 Top, detailing accessories, dimensions, and mounting procedures for PC water cooling systems. Includes safety instructions and compatibility notes.
Vorview Alphacool Core Flat Reservoir Installation and User Guide
Comprehensive guide for installing and using the Alphacool Core Flat Reservoir, featuring D5/VPP pump compatibility, ARGB lighting, and detailed assembly instructions for PC water cooling systems.