Model: 63407 | Brand: DRUMMOND
This DRUMMOND 1 HP Stainless Steel Shallow Well Pump and Tank system is designed for residential water setups. It features a 5-gallon hardened steel alloy tank and a stainless steel housing and volute, ensuring durability and compatibility with potable water due to its lead-free fittings and rubber seals. The pump offers a maximum flow of 950 GPH and a total head lift of 115.5 ft., with a maximum well depth of 26 ft. It operates at 120 Volts (AC) and includes thermal protection with automatic reset for enhanced safety and longevity. The maximum water pressure is 50 PSI.

Image: The DRUMMOND 1 HP Stainless Steel Shallow Well Pump and Tank, featuring a green tank base, a stainless steel pump head, and a green motor housing. A pressure gauge and electrical control box are visible on the pump head.
Read and understand all safety warnings and instructions before operating this product. Failure to follow these instructions may result in electric shock, fire, serious injury, or death.
Regelmäßige Wartung gewährleistet die Langlebigkeit und den effizienten Betrieb Ihrer Pumpe.
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Pumpe startet oder läuft nicht. | No power; tripped circuit breaker; faulty wiring; motor overload. | Check power supply; reset breaker; inspect wiring; allow motor to cool and reset thermal protection. |
| Pump runs but no water or low pressure. | Pump not primed; air leak in suction line; low water level in well; clogged impeller. | Re-prime pump; check all suction connections for leaks; verify well water level; inspect and clear impeller. |
| Die Pumpe schaltet sich häufig ein und aus. | Waterlogged pressure tank; air leak in system; faulty pressure switch. | Check and adjust pressure tank air charge; inspect for leaks; test or replace pressure switch. |
| Pumpe ist laut. | Air in pump; cavitation; worn bearings. | Re-prime pump; ensure adequate water supply; contact qualified service technician for bearing issues. |
| Besonderheit | Spezifikation |
|---|---|
| Marke | TROMMELN |
| Modellnummer | 63407 |
| PS | 1 PS |
| Maximaler Durchfluss | 950 GPH (15.83 Gallonen pro Minute) |
| Entladung | 1 Zoll |
| Totaler Kopflift | 115.5 Fuß. |
| Maximum Well Depth | 26 Fuß. |
| Maximaler Wasserdruck | 50 PSI |
| Tankinhalt | 5 gal. (hardened steel alloy) |
| Bandtage | 120 Volt (Wechselstrom) |
| Material | Stainless Steel (housing and volute), Rubber |
| Artikelgewicht | 32.5 Pfund |
| Abmessungen (Paket) | 21 x 18 x 11 Zoll |
| Thermischer Schutz | Automatisches Zurücksetzen |
This DRUMMOND product is backed by a manufacturer's warranty. Please refer to the warranty card included with your purchase for specific terms and conditions, including coverage duration and limitations. Keep your proof of purchase for warranty claims.
For technical assistance, troubleshooting beyond this manual, or warranty service, please contact DRUMMOND customer support. Contact information can typically be found on the product packaging or the manufacturer's official webWebsite.
Note: Protection plans may be available for extended coverage. Check with your retailer for details.
![]() |
Drummond 1 PS Edelstahl-Flachbrunnenpumpe und -tank – Benutzerhandbuch Bedienungsanleitung und Sicherheitshinweise für die Drummond 1 HP Edelstahl-Flachbrunnenpumpe und den Tank. Enthält Informationen zu Montage, Betrieb, Inspektion, Wartung und Fehlerbehebung. |
![]() |
DRUMMOND 1 PS Edelstahl-Flachbrunnenpumpe und Tank – Bedienungsanleitung & Sicherheitshinweise Ausführliche Bedienungsanleitung und Sicherheitshinweise für die DRUMMOND 1 PS Edelstahl-Flachbrunnenpumpe mit Tank (Artikel 63407). Beinhaltet Informationen zu Installation, Betrieb, Wartung, Fehlersuche und Garantie. |
![]() |
Drummond Tauchpumpe für Flachbrunnen – Bedienungsanleitung & Sicherheitshinweise (1/3 PS & 1/6 PS) Ausführliche Bedienungsanleitung und Sicherheitshinweise für Drummond 1/3 PS und 1/6 PS Tauchpumpen für Flachbrunnen. Enthält technische Daten, Installations-, Betriebs- und Wartungshinweise, eine Ersatzteilliste sowie Garantieinformationen. |
![]() |
Drummond 1/3 & 1/6 HP Tauchpumpe für flache Brunnen – Benutzerhandbuch und Sicherheitshinweise Umfassende Bedienungsanleitung und Sicherheitshinweise für die Drummond 1/3 PS und 1/6 PS Tauchpumpen für flache Brunnen (Modelle 63318, 63319). Enthält Informationen zu Installation, Betrieb, Wartung, Ersatzteilliste und Garantie. |
![]() |
Drummond 1/10 HP Nicht-Tauch-Transferpumpe – Benutzerhandbuch und Sicherheitshinweise Dieses Handbuch enthält Sicherheitshinweise, Betriebsverfahren, Wartungsrichtlinien und Ersatzteillisten für die Drummond 1/10 HP Nicht-Tauchpumpe (Artikel 63317). Es behandelt die elektrische Sicherheit, die ordnungsgemäße Verwendung, die Installation und eine 90-tägige eingeschränkte Garantie. |
![]() |
Drummond 1/10 HP Nicht-Tauch-Transferpumpe – Benutzerhandbuch und Sicherheitshinweise Umfassende Bedienungsanleitung und Sicherheitshinweise für die Drummond 1/10 HP Nicht-Tauch-Transferpumpe (Modell 63317). Umfasst Spezifikationen, Installation, Betrieb, Wartung, Fehlerbehebung, Teileliste und Garantieinformationen. |