1. Einleitung
This instruction manual provides essential information for the safe installation, operation, and maintenance of the Hager SVN129 LED Pilot Light. The SVN129 is a compact indicator designed for electrical panels and control systems, featuring red, green, and orange LED illumination and operating on a 230V AC supply.
Bitte lesen Sie diese Anleitung vor der Installation sorgfältig durch und bewahren Sie sie zum späteren Nachschlagen auf.
2. Sicherheitshinweise
WARNUNG: Electrical installation should only be performed by qualified and authorized personnel. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Vor der Installation oder Wartung des Geräts muss immer die Stromzufuhr am Hauptsicherungsschalter unterbrochen werden.
- Stellen Sie sicher, dass alle Verkabelungen den lokalen und nationalen Elektrovorschriften entsprechen.
- Das Gerät darf nicht bedient werden, wenn es beschädigt erscheint.
- This device is designed for indoor use in dry locations unless otherwise specified.
- Überprüfen Sie die Liefermengetage entspricht der Nennspannung des Gerätstage (230 V Wechselstrom).
3. Produktüberschreitungview
The Hager SVN129 is an LED pilot light designed for clear visual indication within electrical systems. Its key features include:
- LED-Beleuchtung: Provides bright red, green, and orange light for status indication.
- Bandtage-Bewertung: Betrieb mit 230V Wechselstrom.
- Modulgröße: Occupies 1 module space in a standard electrical panel.
- Frequenz: Designed for 50/60 Hz systems.

Figure 1: Hager SVN129 LED Pilot Light. This image displays the front view of the SVN129 LED pilot light, highlighting its compact form factor suitable for integration into electrical panels. The indicator features a clear lens, designed to display red, green, or orange light depending on the operational status.
4. Einrichtung und Installation
Installation of the Hager SVN129 LED Pilot Light should be carried out by a qualified electrician in accordance with all applicable electrical standards and regulations.
- Stromabschaltung: Ensure the main power supply to the installation area is completely disconnected and secured against accidental re-connection.
- Montage: The SVN129 is designed for DIN rail mounting. Snap the device onto the DIN rail in the desired position within the electrical enclosure.
- Verdrahtung: Connect the 230V AC supply wires to the designated terminals on the pilot light. Refer to the wiring diagram on the device or packaging for correct polarity and connection points. Typically, these devices have two terminals for line and neutral connections.
- Sichere Verbindungen: Ensure all terminal screws are tightened securely to prevent loose connections, which can cause overheating or intermittent operation.
- Überprüfung: Double-check all wiring connections before restoring power.
- Wiederherstellung der Stromversorgung: Restore power to the circuit. The pilot light should illuminate according to the circuit status it is monitoring.
5. Bedienungsanleitung
The Hager SVN129 LED Pilot Light operates as a visual indicator. Once correctly installed and connected to a 230V AC circuit, it will illuminate to indicate the status of that circuit or a specific condition within an electrical system.
- The specific color (red, green, or orange) displayed by the LED will depend on the model variant and the intended application for which it was selected.
- No user interaction is required for its operation beyond initial installation.
6. Wartung
The Hager SVN129 LED Pilot Light is designed for minimal maintenance. However, periodic checks can ensure continued reliable operation.
- Reinigung: If necessary, gently wipe the surface of the pilot light with a soft, dry, or slightly damp Tuch. Keine Scheuer- oder Lösungsmittel verwenden.
- Inspektion: Periodically inspect the device for any signs of physical damage, discoloration, or loose connections. If any issues are found, disconnect power and consult a qualified electrician.
- Keine vom Benutzer zu wartenden Teile: The LED pilot light contains no user-serviceable parts. Do not attempt to open or repair the unit.
7. Fehlerbehebung
If the Hager SVN129 LED Pilot Light is not functioning as expected, consider the following troubleshooting steps:
- Licht leuchtet nicht:
- Prüfen Sie, ob die Stromversorgung des Stromkreises aktiv ist.
- Verify that the pilot light is correctly wired and connections are secure.
- Sicherstellung der Versorgungsvoltage ist 230 V AC.
- If the above steps do not resolve the issue, the device may be faulty and require replacement by a qualified electrician.
- Intermittierender Betrieb:
- Check for loose wiring connections at the terminals.
- Ensure stable power supply to the circuit.
For issues not covered here, contact a qualified electrician or Hager customer support.
8. Spezifikationen
| Besonderheit | Detail |
|---|---|
| Modellnummer | SVN129 |
| Marke | Hager |
| Lamp Typ | LED |
| LED-Farben | Rot, Grün, Orange |
| Bandtage | 230 V Wechselstrom |
| Assigned Frequency | 50/60 Hz |
| Anzahl der Module | 1 |
| Wastage | 7 Watt |
| Artikelpaket Menge | 1 |
| Batterien erforderlich? | NEIN |
| Hersteller | Hager |
9. Garantie und Support
Informationen zu den Garantiebedingungen finden Sie in der mit Ihrem Kauf gelieferten Dokumentation oder auf der offiziellen Hager-Website. website. For technical support or inquiries, please contact Hager customer service through their official channels.
Hinweis: Produktspezifikationen und Aussehen können ohne vorherige Ankündigung geändert werden.