DAB 60161182

DAB E.SYBOX 230V Wasserdruckerhöhungssystem – Benutzerhandbuch

Modell: 60161182

1. Einleitung

The DAB E.SYBOX is an integrated electronic water booster system designed for domestic and residential applications. This system provides constant water pressure while optimizing energy consumption. It is suitable for use with potable water in domestic plants, for gardening, and irrigation. The E.SYBOX can also be used to create groups of up to four pumps.

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your E.SYBOX system. Please read it thoroughly before installation and keep it for future reference.

2. Sicherheitshinweise

WARNING: Before performing any operation on the pump, disconnect it from the main power supply.

  • Stellen Sie sicher, dass die Stromversorgungslautstärketage matches the specifications of the E.SYBOX (230V).
  • Installation und Wartung dürfen nur von qualifiziertem Personal durchgeführt werden.
  • Do not operate the pump with flammable or explosive liquids.
  • Schützen Sie das Gerät vor Frost.
  • Sorgen Sie für eine ausreichende Belüftung rund um das Gerät, um eine Überhitzung zu vermeiden.
  • Das Gerät muss ordnungsgemäß geerdet sein.

3. Packungsinhalt

Prüfen Sie beim Auspacken, ob alle Komponenten vorhanden und unbeschädigt sind:

  • DAB E.SYBOX Water Booster System Unit
  • Netzkabel
  • Connection Pieces (e.g., 1" plastic unions)
  • Benutzerhandbuch (dieses Dokument)

4. Einrichtung und Installation

The E.SYBOX is designed for straightforward installation and requires no additional components for basic setup. It can be installed either vertically or horizontally.

4.1. Auswahl eines Installationsortes

Wählen Sie einen Standort aus, der:

  • Protected from direct sunlight and extreme temperatures.
  • In a closed space without a high level of air exchange, as the unit is water-cooled and quiet.
  • Für Wartungsarbeiten zugänglich.
  • Near the water source and the distribution system.

4.2. Physische Installation

  1. Positionierung des Geräts: Place the E.SYBOX on a stable, level surface. The anti-vibration feet help reduce noise. The unit can be positioned vertically or horizontally.
  2. DAB E.SYBOX Water Booster System, front view

    Abbildung 1: Vorderseite view of the DAB E.SYBOX unit, showing the display and general form factor.

  3. Anschluss der Wasserleitungen: Connect the inlet pipe from your water source to the suction port and the outlet pipe to your distribution system. Use the provided 1" plastic unions for secure connections. Ensure all connections are watertight.
  4. DAB E.SYBOX Water Booster System, rear view mit Verbindungen

    Abbildung 2: Rückseite view of the E.SYBOX, highlighting the water inlet and outlet connections.

  5. Elektrischer Anschluss: Connect the power cord to a grounded 230V AC outlet. Ensure the power supply is stable and protected from surges.
  6. Vorbereiten der Pumpe (falls erforderlich): For initial startup or after maintenance, ensure the pump is filled with water before operation to prevent dry running. Refer to the display for priming instructions.

5. Bedienungsanleitung

The E.SYBOX features an adjustable, high-resolution LCD display for easy operation and monitoring.

5.1. Erstes Einschalten

  1. Once connected to power, the LCD display will illuminate.
  2. Follow the on-screen prompts for initial setup, which may include language selection and basic pressure settings.

5.2. Einstellen des gewünschten Drucks

The E.SYBOX allows you to set your desired water pressure. The system will then maintain this constant pressure by adjusting pump speed.

  • Navigate through the LCD menu using the control buttons adjacent to the display.
  • Locate the "Pressure Setting" option.
  • Adjust the pressure value (e.g., in PSI or Bar) to your preference. The system can deliver up to 210 ft (approx. 90 PSI) of head.
  • Confirm your selection. The system will automatically adjust to maintain this pressure.
DAB E.SYBOX Water Booster System with power and flow specifications

Figure 3: E.SYBOX display showing operational parameters such as power consumption (360W), pressure (3 Bar / 43 PSI), and flow rate (3.2 GPM / 12 l/min).

5.3. Überwachung der Leistung

The LCD display provides real-time statistics:

  • Druck: Current system pressure.
  • Durchflussrate: Instantaneous water flow.
  • Stromverbrauch: Energy consumption of the unit.
  • Alarme/Warnungen: Notifications for any operational issues.

6. Wartung

Regular maintenance ensures the longevity and optimal performance of your E.SYBOX system.

6.1. Routineprüfungen

  • Sichtprüfung: Periodically check for any leaks, unusual noises, or visible damage.
  • Air Exchange: Ensure the area around the unit is not obstructed to allow for proper air circulation for the water-cooled motor.

6.2. Sensorreinigung

Over time, sediment may accumulate and affect the flow sensors. The E.SYBOX comes with a tool for cleaning these sensors.

  1. Stromversorgung trennen: Always disconnect the unit from the power supply before any maintenance.
  2. Locate Sensors: Refer to the detailed diagram in the full technical manual (if available) to locate the flow sensors.
  3. Sauber: Use the provided tool to carefully clean any accumulated sediment from the sensors.
  4. Erneut verbinden: Bauen Sie alle ausgebauten Teile wieder zusammen und schließen Sie die Stromversorgung wieder an.

6.3. Winterfestmachung

If the unit is installed in an area subject to freezing temperatures, it must be drained to prevent damage.

  • Trennen Sie die Stromversorgung.
  • Drain all water from the pump and associated piping.
  • Store in a frost-free environment if possible, or ensure complete drainage.

7. Fehlerbehebung

This section addresses common issues you might encounter with your E.SYBOX system.

ProblemMögliche UrsacheLösung
No water flow / Pump not startingNo power; Air in pump; Clogged inlet; Low water level in source.Check power connection; Prime the pump; Clean inlet filter; Ensure adequate water supply.
NiederdruckIncorrect pressure setting; Partially clogged filter/pipes; Air in system.Adjust pressure setting on LCD; Inspect and clean filters/pipes; Bleed air from system.
Pump runs continuously / Frequent on/off cyclingLeak in system; Small continuous flow (e.g., dripping faucet); Faulty sensor.Check for leaks in plumbing; Address small continuous flows; Contact support if sensor is suspected.
Ungewöhnliche Geräusche oder VibrationenAir in pump; Loose connections; Foreign object in pump.Prime the pump; Check and tighten all connections; Disconnect power and inspect pump impeller (if safe and accessible).
LCD display error messageSpezifischer Systemfehler.Note the error code and consult the full technical manual or contact customer support.

Sollte das Problem nach Anwendung dieser Lösungsansätze weiterhin bestehen, wenden Sie sich bitte an den Kundendienst.

8. Spezifikationen

BesonderheitDetail
Modell60161182
Bandtage230 Volt
StromquelleWechselstrom/Gleichstrom
Maximaler Durchfluss32 Gallonen pro Minute (GPM)
Maximale Hubhöhe (Kopf)210 Fuß
Flüssigkeitstemperaturbereich+32 to +95°F (domestic use), +32 to +102°F (other uses)
Maximale Saugtiefe26 Fuß
Artikelgewicht57 Pfund
Produktabmessungen (L x B x H)14.25 x 10.35 x 22.2 Zoll
MaterialABS
Integrated Expansion Tank0.5 Gallone

9. Garantie und Support

9.1. Garantieinformationen

DAB provides a limited warranty for the E.SYBOX 230V Water Booster System against defects in materials and workmanship under normal use and service. The specific duration and terms of the warranty may vary by region and purchase date. Please retain your proof of purchase for warranty claims.

For detailed warranty terms and conditions, refer to the warranty card included with your product or visit the official DAB webWebsite.

9.2. Kundendienst

If you require technical assistance, have questions about installation, operation, or maintenance, or need to report a problem, please contact DAB customer support.

  • Online-Hilfe: Visit the official DAB Pumps website for FAQs, technical documents, and contact forms.
  • Telefonischer Support: Refer to the contact information provided on the DAB webDie regionalen Supportnummern finden Sie auf der Website oder auf Ihrer Produktverpackung.
  • When contacting support, please have your product model (60161182) and serial number (if applicable) ready.