Sawo ARI3-90NB-P

SAWO ARIES ROUND ARI3 Elektrischer Saunaofen Benutzerhandbuch

Model: ARI3-90NB-P

1. Einleitung

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your SAWO ARIES ROUND ARI3 Electric Sauna Heater. Please read this manual thoroughly before installation and use, and keep it for future reference.

Produkt überview

The SAWO ARIES ROUND ARI3 is a high-quality electric sauna heater designed for both home and commercial use. Its vertical cylindrical shape ensures efficient heat distribution and steam generation. The heater features a durable stainless steel casing and an intuitive integrated control panel for ease of use.

SAWO ARIES ROUND ARI3 Electric Sauna Heater

Figure 1: SAWO ARIES ROUND ARI3 Electric Sauna Heater with sauna stones.

Sicherheitshinweise

Always follow local electrical codes and safety regulations. Installation should be performed by a qualified electrician.

2. Einrichtung und Installation

Auspacken und Inspektion

Carefully unpack the sauna heater and inspect it for any signs of damage during transit. Report any damage to your supplier immediately.

Stone Placement

The ARI3 model can hold up to 60 kg of sauna stones (diameter 5-10 cm). Arrange the stones loosely around the heating elements to allow for proper air circulation. Do not pack stones too tightly. The heating elements are separated from the stones by a special stone spacer to prolong their lifespan.

Close-up of sauna heater base and controls

Abbildung 2: Nahaufnahme view of the heater's base and integrated controls.

Elektrische Verbindung

The SAWO ARIES ROUND ARI3 is a multi-voltage heater, supporting either 230V single-phase (fuse: 1x40A) or 400V 3-phase (fuse: 3x16A) installation. Ensure the electrical supply matches the heater's requirements. The connection cable must be type HO7RN-F or equivalent and is not included.

Placement and Safety Distances

The heater is a floor-standing model. Maintain minimum safety distances from walls and ceiling.

Table 1: Minimum Safety Distances
MessungDistanz
Mindestabstand zur Decke1200 mm
Minimum distance to side walls100 mm
SAWO ARIES ROUND ARI3 heater installed in a sauna

Figure 3: Heater installed in a sauna, demonstrating vertical placement.

3. Bedienungsanleitung

Integriertes Bedienfeld

The SAWO ARIES ROUND ARI3 features a convenient built-in control panel with an intuitive interface. The illuminated rotary knobs allow for easy adjustment even in low light conditions. The timer and thermostat controls can be switched sides for user convenience.

Sauna heater with wooden guard ring accessory

Figure 4: Heater with an optional wooden guard ring, highlighting the integrated controls at the base.

Einstellen des Timers

The timer has an operating time of 1 to 4 hours and a preset time function of 1 to 8 hours.

  1. Turn the timer knob to select the desired operating duration.
  2. For a delayed start, use the preset time function to set when the heater should begin operation.

Temperatur einstellen

The thermostat automatically maintains the selected temperature.

  1. Turn the thermostat knob to set your desired sauna temperature.
  2. The heater will cycle on and off to maintain this temperature.

Generating Steam

You can generate steam by pouring water onto the hot sauna stones, not only from the top but also from the sides due to the heater's efficient cylindrical design. Use only clean water.

4. Wartung

Reinigung

Ensure the heater is completely cool and disconnected from power before cleaning. Wipe the stainless steel casing mit Adamp Tuch. Keine Scheuer- oder Lösungsmittel verwenden.

Sauna Stone Replacement

Sauna stones should be inspected regularly and replaced when they start to crumble or lose their porous structure. This typically occurs every 1-2 years depending on usage. Replacing stones ensures efficient heating and proper steam generation.

Close-up of sauna stones in the heater

Abbildung 5: Nahaufnahme view of the sauna stones within the heater's stainless steel grid.

5. Fehlerbehebung

If you encounter issues with your SAWO ARIES ROUND ARI3 heater, refer to the following common problems and solutions. For more complex issues, contact a qualified service technician.

Tabelle 2: Anleitung zur Fehlerbehebung
ProblemMögliche UrsacheLösung
Heizung heizt nichtNo power supply; tripped circuit breaker; faulty heating element; thermostat set too low.Check power connection and circuit breaker. Ensure thermostat is set correctly. If elements are faulty, contact service.
Sauna not reaching desired temperatureInsufficient heating time; sauna room too large for heater; poor insulation; stones packed too tightly.Allow more time for heating. Verify sauna room volume is within heater's capacity (8-13 m³). Rearrange stones for better airflow.
Excessive steam or water drippingToo much water poured on stones; stones are too old/crumbling.Pour less water. Replace old sauna stones.

6. Technische Daten

Table 3: SAWO ARIES ROUND ARI3-90NB-P Specifications
BesonderheitDetail
ModellARI3-90NB-P
Leistungsabgabe9.0 kW
Abmessungen (H x B)930 mm x 300 mm
Gewicht14 kg
InstallationstypBodenständig
Max. Stone Capacity60 kg (stones Ø 5-10 cm)
Empfohlene Saunaraumgröße8-13 m³
Bandtage Optionen230V 1-phase (1x40A fuse) or 400V 3-phase (3x16A fuse)
MaterialEdelstahl
BedienfeldIntegrated, illuminated timer (1-4h operation, 1-8h preset) and thermostat

7. Garantie und Support

Garantieinformationen

The SAWO ARIES ROUND ARI3 heater comes with a manufacturer's warranty:

Please retain your proof of purchase for warranty claims. The warranty does not cover sauna stones or silicone connection cables, as these are not included with the heater.

Kundenservice

For technical assistance, spare parts, or warranty inquiries, please contact your local SAWO distributor or the point of purchase.

Hersteller: Sawo
Modellnummer: ARI3-90NB-P

Zugehörige Dokumente - ARI3-90NB-P

Vorview Handbuch zum Leistungsregler Saunova 2.0 - SAWO
Umfassendes Benutzerhandbuch für den SAWO Saunova 2.0 Power Controller mit detaillierten Informationen zu Installation, Betrieb, Sicherheitsvorkehrungen und technischen Daten für Saunaheizsysteme.
Vorview Installationsdiagramme und Sicherheitsabstände für SAWO Cirrus-Heizgeräte
Umfassende Installationsdiagramme und Angaben zum Mindestsicherheitsabstand für SAWO Cirrus-Heizgeräte, sowohl für Modelle mit separater als auch mit eingebauter Steuerung. Wichtige Anleitung für die ordnungsgemäße Installation.
Vorview SAWO Glass Front Sauna Room Assembly Manual
This official assembly manual from SAWO guides users through the complete installation process for their Glass Front Sauna Rooms. It features detailed parts lists, step-by-step assembly instructions, electrical layout diagrams, and essential maintenance tips for models like the 1414LS/RS and 2020ML.
Vorview SAWO Tower Heater Round Benutzerhandbuch
Dieses Benutzerhandbuch enthält detaillierte Anweisungen zur Installation, Bedienung und Wartung des SAWO Tower Heater Round. Es behandelt Sicherheitsvorkehrungen, technische Daten, Fehlerbehebung und Ersatzteile.
Vorview SAWO Innova Contactor Unit 2.0 Installation and Operation Manual
Comprehensive manual for the SAWO Innova Contactor Unit 2.0, detailing installation, technical specifications, precautions, and operation for sauna heating systems. Not for use in USA, Canada, and Mexico.
Vorview SAWO Infrarot 2.0 Steuereinheit – Handbuch: Installations- und Bedienungsanleitung
Ausführliches Benutzerhandbuch für die SAWO Infrared 2.0 Steuereinheit. Enthält detaillierte Anweisungen zur Installation, Bedienung, Sicherheitsrichtlinien und Fehlerbehebung für Infrarotsaunaräume.