1. Einführung und Endeview
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Gree Multi21+ Tri-Zone Floor/Ceiling Mini Split Air Conditioner Heat Pump. This system is designed to provide heating and cooling for up to three separate zones, utilizing Gree's G10 inverter technology for energy efficiency and consistent temperature control. The indoor units offer flexible installation options, suitable for both floor-level mounting and ceiling suspension.

Image 1.1: Key features and certifications of the Gree Multi21+ system, including 5-year parts warranty, R410A refrigerant, heating & cooling capability, ETL listing, G10 Inverter Technology, AHRI certification, and Energy Star rating (except 42k model).
2. Sicherheitshinweise
Please read all safety warnings and instructions carefully before installing or operating this unit. Failure to follow these instructions may result in property damage, personal injury, or death. Keep this manual for future reference.
- Professionelle Installation erforderlich: Installation, maintenance, and repair of this equipment must be performed by a qualified, licensed HVAC technician. Improper installation can lead to electric shock, fire, water leakage, and void the product warranty.
- Elektrische Sicherheit: Ensure the unit is properly grounded and connected to a dedicated power supply with appropriate circuit protection. Do not operate with wet hands.
- Umgang mit Kältemitteln: This system uses R410A refrigerant. Only qualified personnel should handle refrigerant.
- Freigaben: Um eine ordnungsgemäße Luftzirkulation und den Zugang für Wartungsarbeiten zu gewährleisten, müssen sowohl um die Innen- als auch um die Außengeräte herum ausreichende Abstände eingehalten werden.
- Warnung zu Proposition 65: Dieses Produkt kann Sie Chemikalien aussetzen, die im US-Bundesstaat Kalifornien als krebserregend und fortpflanzungsschädigend gelten. Weitere Informationen finden Sie unter [Link einfügen]. www.P65Warnings.ca.gov.
3. Produktkomponenten
Your Gree Multi21+ Tri-Zone system includes the following main components:
- Außengerät (Verflüssigungseinheit): The primary unit responsible for heat exchange.
- Indoor Floor/Ceiling Units (x3): Distribute conditioned air within each zone.
- Fernbedienungen: For operating each indoor unit.

Image 3.1: Gree Floor/Ceiling indoor unit shown with its wired and wireless remote controls.

Image 3.2: Gree Multi-Zone outdoor condensing unit, featuring the inverter technology.
4. Einrichtung und Installation
Installation of this multi-zone mini-split system is complex and requires specialized tools and knowledge. It must be performed by a state-licensed HVAC contractor to ensure proper function, safety, and warranty eligibility.
- Standortauswahl: Choose appropriate locations for the outdoor unit and each indoor unit, considering airflow, drainage, and structural support.
- Montage: Indoor units can be mounted low on a wall or suspended from the ceiling. Ensure secure fastening according to manufacturer guidelines.
- Leitungssatzverbindung: The system requires 1/4" x 3/8" line sets (x2) for refrigerant connections, which are not included and must be purchased separately.
- Elektroverkabelung: Proper electrical connections must be made by a qualified electrician, adhering to all local codes and regulations. The unit operates on 208/230V.
- Vacuum and Refrigerant Charging: The refrigerant lines must be evacuated to a deep vacuum before releasing refrigerant. This step is critical for system performance and longevity.
5. Bedienungsanleitung
Each indoor unit is controlled independently via its dedicated remote control. Refer to the specific remote control manual for detailed button functions and display indicators.
- Ein-/Ausschalten: Drücken Sie den Ein-/Ausschalter auf der Fernbedienung, um das Gerät ein- oder auszuschalten.
- Modusauswahl: Select desired operating mode (Cool, Heat, Fan, Dry, Auto) using the mode button.
- Temperatureinstellung: Use the up/down arrows to set the desired temperature for each zone. The G10 inverter technology will maintain this temperature steadily.
- Lüftergeschwindigkeit: Passen Sie die Lüftergeschwindigkeit (Auto, Niedrig, Mittel, Hoch) nach Bedarf an.
- Timer-Funktion: Programmieren Sie das Gerät so, dass es sich zu bestimmten Zeiten ein- oder ausschaltet.
- Mehrzonensteuerung: Each indoor unit can be set to a different mode and temperature, allowing customized comfort in up to three zones.

Image 5.1: Illustration of the system's dual cooling and heating capabilities.

Abbildung 5.2: Beispielample of multi-zone temperature control within a floor plan, demonstrating independent temperature settings for different areas.
6. Wartung
Regular maintenance is crucial for the efficiency and longevity of your mini-split system. Always disconnect power before performing any maintenance.
- Reinigung des Luftfilters: Clean the indoor unit's air filters every 2-4 weeks, or more frequently depending on usage and air quality. Wash with mild detergent and water, then dry completely before reinstalling.
- Reinigung der Außeneinheit: Keep the outdoor unit free from debris, leaves, and obstructions. Periodically clean the outdoor coil with a soft brush or water spray.
- Entwässerungsprüfung: Ensure the condensate drain lines are clear and free-flowing to prevent water leaks.
- Professionelle Inspektion: Schedule annual professional maintenance with a licensed HVAC technician to check refrigerant levels, electrical connections, and overall system performance.
7. Fehlerbehebung
Bevor Sie den Kundendienst kontaktieren, ...view the following common issues and solutions. For complex problems, always consult a licensed HVAC technician.
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Das Gerät lässt sich nicht einschalten | Kein Strom, Sicherung ausgelöst, Batterien der Fernbedienung leer | Check power supply, reset breaker, replace remote batteries |
| Unzureichende Kühlung/Heizung | Verschmutzte Luftfilter, blockiertes Außengerät, falsche Betriebseinstellung, zu wenig Kältemittel | Clean filters, clear obstructions, verify mode, contact technician for refrigerant check |
| Wasserleckage am Innengerät | Verstopfte Abflussleitung, unsachgemäße Installation | Abflussrohr reinigen, Techniker zur Inspektion kontaktieren |
| Ungewöhnliche Geräusche | Loose parts, fan obstruction, compressor issue | Inspect for loose parts, clear obstructions, contact technician |
8. Spezifikationen
Detailed technical specifications for the Gree Multi21+ Tri-Zone Floor/Ceiling Mini Split Air Conditioner Heat Pump, Model MULTI42CFLR303.
| Spezifikation | Wert |
|---|---|
| Marke | GRÜN |
| Modellinformationen | MULTI42CFLR303 |
| Kapazität | 42,000 BTU (3.5 Tonnen) |
| Kühlleistung | 42000 britische Wärmeeinheiten |
| Saisonales Energieeffizienzverhältnis (SEER) | 21 |
| Bandtage | 230 Volts (208/230V) |
| Kältemittel | R 410A |
| Artikelgewicht | 198 Pfund |
| Technische Daten | 17 x 42 x 43 Zoll |
| Installationstyp | Geteiltes System |
| Materialtyp | Stahl |
| Besonderheit | Eco-friendly, Lightweight |

Image 8.1: Detailed specifications table for Gree Floor/Ceiling indoor units, including cooling/heating capacity, airflow, sound level, and dimensions.

Image 8.2: Measurement table for various BTU capacities of Gree Floor/Ceiling indoor and outdoor units.
9. Garantieinformationen
Your Gree Multi21+ Tri-Zone system comes with a manufacturer's warranty:
- Teilegarantie: 5 Jahre
- Kompressorgarantie: 7 Jahre
Wichtiger Hinweis: To be eligible for this warranty, installation must be performed by a state-licensed HVAC contractor. Any issues arising from improper installation by an unlicensed individual may void the warranty.
10. Unterstützung und Kontakt
For technical assistance, warranty claims, or service inquiries, please contact your installing HVAC contractor or the authorized Gree distributor from whom you purchased the unit. Ensure you have your model number (MULTI42CFLR303) and proof of purchase readily available.