Einführung
This user manual provides comprehensive instructions for the safe and efficient operation, setup, and maintenance of the JBC JTSE-2QA Digital Hot Air Rework Station. Please read this manual thoroughly before using the device to ensure optimal performance and longevity.
Produkt überview

Figure 1: The JBC JTSE-2QA Digital Hot Air Rework Station, featuring the main unit with digital display, the hot air tool, and its dedicated stand. This station is designed for precise and controlled hot air applications in electronics rework.
The JBC JTSE-2QA is a high-performance digital hot air rework station designed for professional electronics repair and assembly. It offers precise temperature control and airflow management, making it ideal for desoldering and soldering surface-mount components (SMD).
Sicherheitshinweise
Beachten Sie stets die folgenden Sicherheitsvorkehrungen, um Verletzungen und Schäden am Gerät zu vermeiden:
- Ensure the station is connected to a properly grounded power outlet (230V).
- Do not touch the hot air nozzle or heated components directly. Use appropriate tools and allow components to cool.
- Operate the station in a well-ventilated area to dissipate fumes.
- Keep flammable materials away from the hot air stream.
- Vor jeglichen Wartungs- oder Reinigungsarbeiten muss das Netzkabel abgezogen werden.
- Do not operate the station if the power cord or unit is damaged.
- Dieses Gerät ist nur für den professionellen Gebrauch bestimmt. Außerhalb der Reichweite von Kindern aufbewahren.
Aufstellen
- Auspacken: Nehmen Sie alle Komponenten vorsichtig aus der Verpackung. Überprüfen Sie, ob alle im Abschnitt „Lieferumfang“ aufgeführten Artikel vorhanden sind.
- Platzierung: Place the main unit on a stable, heat-resistant, and level surface. Ensure adequate clearance around the unit for ventilation.
- Connect Hot Air Tool: Connect the hot air tool's hose and electrical connector to the corresponding ports on the main unit. Ensure a secure connection.
- Connect Stand: Position the hot air tool stand near the main unit and place the hot air tool securely in its holder when not in use. The stand often includes a sensor to detect when the tool is placed, activating standby mode.
- Stromanschluss: Plug the power cord into the main unit's power inlet, then connect it to a grounded 230V AC power outlet.
Bedienungsanleitung
1. Ein-/Ausschalten
Press the power button located on the front panel to turn the station on or off. The digital display will illuminate upon startup.
2. Setting Temperature and Airflow
Verwenden Sie die Navigationsschaltflächen (+, -, OK) on the front panel to adjust the hot air temperature and airflow settings. The display shows the current and set values. The temperature range is typically 150°C to 450°C.
- Temperatur: Adjust the desired hot air temperature for your application.
- Luftstrom: Control the air volume output from the nozzle. Start with lower airflow for delicate components and increase as needed.
3. Using the Hot Air Tool
When the hot air tool is removed from its stand, the heating element will activate and the station will begin to reach the set temperature. When returned to the stand, the station will enter standby mode, cooling down the tool to a safe temperature.
- Wählen Sie die passende Düse für Ihre Anwendung.
- Maintain a safe distance between the nozzle and the component to avoid overheating.
- Move the hot air tool in a circular motion to ensure even heating.
Wartung
Regular maintenance ensures the longevity and optimal performance of your JBC JTSE-2QA station.
- Reinigung: Vor der Reinigung die Stromzufuhr unterbrechen. Verwenden Sie ein weiches, fusselfreies Tuch.amp cloth to wipe down the exterior of the main unit and the hot air tool. Do not use abrasive cleaners or solvents.
- Düsenpflege: Periodically inspect the hot air nozzles for blockages or damage. Clean them as needed to ensure proper airflow.
- Luftfilter: Check and clean or replace the air filter (if applicable) according to the manufacturer's recommendations to maintain optimal airflow and prevent dust accumulation.
- Lagerung: Store the station in a clean, dry environment when not in use.
Fehlerbehebung
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Die Station lässt sich nicht einschalten. | Keine Stromversorgung; loses Netzkabel. | Überprüfen Sie den Stromanschluss und stellen Sie sicher, dass die Steckdose funktioniert. |
| Hot air tool not heating. | Tool not properly connected; tool in stand (standby mode); faulty heating element. | Ensure tool is securely connected and removed from stand; contact support if element is faulty. |
| Unzureichender Luftstrom. | Blocked nozzle; dirty air filter. | Clean or replace nozzle; check and clean/replace air filter. |
| Temperaturschwankungen. | Sensor issue; unstable power supply. | Ensure stable power; contact support for sensor issues. |
Technische Daten
| Besonderheit | Detail |
|---|---|
| Modellnummer | JTSE-2QA |
| Hersteller | JBC |
| Eingangslautstärketage | 230 Volt AC |
| Temperaturbereich | 150 - 450 °C (302 - 842 °F) |
| Abmessungen (L x B x H) | 474 x 368 x 195 cm |
| Artikelgewicht | 4.1 Kilogramm (4104 Gramm) |
| Im Lieferumfang enthaltene Komponenten | Heißluft-Nacharbeitsstation |
| Anzahl der Kanäle | 1 |
Garantie und Support
For warranty information, technical support, or service inquiries regarding your JBC JTSE-2QA Digital Hot Air Rework Station, please contact JBC customer service or visit their official webBewahren Sie Ihren Kaufbeleg als Kaufnachweis für Garantieansprüche auf.