AEMC 6255

AEMC INSTRUMENTS Model 6255 Micro-Ohmmeter User Manual

Precision Resistance Measurement Device

1. Zu Endeview

The AEMC INSTRUMENTS Model 6255 is a high-precision Micro-Ohmmeter designed for accurate resistance measurements. It is capable of measuring resistance from 0.1 microhm up to 2500 ohms, with a resolution of 0.1 microhm. This device is suitable for a wide range of industrial and scientific applications requiring precise low-resistance measurements.

Key features include an LCD display, an output current range of 0.1A to 10A, and internal data storage for up to 1500 test results. It is powered by an 8.5Ah NiMH battery, ensuring portability and extended operation.

2. Sicherheitshinweise

Before operating the AEMC Model 6255, please read and understand all safety instructions. Failure to comply with these instructions may result in electric shock, fire, or damage to the instrument.

3. Produktkomponenten und -merkmale

The AEMC Model 6255 Micro-Ohmmeter comes with the following items:

AEMC INSTRUMENTS Model 6255 Micro-Ohmmeter in its yellow protective case, open to show the control panel and LCD display.

Figure 1: AEMC INSTRUMENTS Model 6255 Micro-Ohmmeter.The image displays the AEMC Model 6255 Micro-Ohmmeter housed within its robust yellow protective case, which is shown open. The device itself is yellow and black, featuring a clear LCD display that shows "72.6" and "0.1365 mΩ". To the left of the display are red and black input terminals labeled C1, P1, P2, and C2. Below the display are several control buttons. On the right side, there is a large rotary dial and a yellow START/STOP button. The overall design emphasizes durability and ease of use for industrial applications.

Schlüsselkomponenten:

4. Einrichtung

4.1 Erstaufladung

The AEMC Model 6255 is powered by an 8.5Ah NiMH battery. Before first use, or if the battery is low, connect the provided charger to the instrument and a suitable power outlet. Allow sufficient time for the battery to fully charge. The charging indicator on the device will provide status.

4.2 Anschließen der Testleitungen

The Model 6255 utilizes a 4-wire (Kelvin) measurement method for high accuracy, which requires four connections to the test object. This method minimizes the impact of lead resistance on the measurement.

  1. Ensure the instrument is turned off before connecting leads.
  2. Connect the current leads (C1 and C2) to the outer points of the resistance to be measured.
  3. Connect the potential leads (P1 and P2) to the inner points of the resistance to be measured. These leads measure the voltage drop across the resistance.
  4. Ensure all connections are secure and clean to prevent erroneous readings.

5. Bedienungsanleitung

5.1 Ein-/Ausschalten

Press and hold the power button (if separate, or a specific function on the rotary dial) to turn the instrument on. Repeat the action to turn it off.

5.2 Auswahl des Messmodus

Use the rotary selector switch to choose the desired measurement range or mode. The Model 6255 supports resistance measurements from 0.1 microhm to 2500 ohms.

5.3 Durchführung einer Messung

  1. Ensure the test leads are correctly connected to the object under test as described in Section 4.2.
  2. Select the appropriate measurement range using the rotary dial. If unsure, start with a higher range and decrease as needed.
  3. Drücken Sie die START/STOP button to initiate the measurement. The instrument will apply a test current (0.1A to 10A) and display the resistance value on the LCD.
  4. Wait for the reading to stabilize. The LCD will show the measured resistance with 0.1 microhm resolution.
  5. Drücken Sie die START/STOP Drücken Sie erneut die Taste, um die Messung zu stoppen.

5.4 Datenspeicherung und -abruf

The Model 6255 can store up to 1500 test results. Refer to the on-screen menu or specific buttons (e.g., "MEM" or "SAVE") for instructions on saving and recalling measurements. The RS232 interface allows for data transfer to a computer for further analysis.

6. Wartung

6.1 Reinigung

Reinigen Sie regelmäßig die Oberfläche des Instruments.asing and display with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure the instrument is turned off and disconnected from any power source before cleaning.

6.2 Batteriepflege

To prolong the life of the 8.5Ah NiMH battery:

6.3 Kalibrierung

The AEMC Model 6255 is a precision instrument. While the product description states "No Calibration Certificate" is included, periodic calibration by a qualified service center is recommended to ensure continued accuracy and compliance with industry standards. Contact AEMC INSTRUMENTS for calibration services.

7. Fehlerbehebung

ProblemMögliche UrsacheLösung
Das Gerät lässt sich nicht einschalten.Batterie ist entladen.Connect the charger and allow the battery to charge fully.
Erratic or unstable readings.Poor test lead connections; Interference; Test object issues.Ensure leads are securely connected and clean. Move away from strong electromagnetic fields. Verify the integrity of the test object.
Display shows "OVERLOAD" or "OL".Resistance value exceeds selected range; Open circuit.Select a higher measurement range. Check for open circuits in the test setup.
Testergebnisse konnten nicht gespeichert werden.Speicher voll.Transfer stored data to a computer via RS232 and clear instrument memory.

8. Spezifikationen

ParameterWert
Modell6255
Widerstandsbereich0.1 microhm to 2500 ohm
Auflösung0.1 microhm
Genauigkeit+/-0.05 Percent
Ausgangsstrom0.1 A bis 10 A
AnzeigeLCD
Stromquelle8.5Ah NiMH Battery
Zählt2,500
SicherheitsbewertungIEC/EN 61010-1 CAT III 50V Pol 2
Datenspeicherung1500 Testergebnisse
SchnittstelleRS232
Technische Daten1 x 1 x 1 Zoll
Artikelgewicht0.01 Unzen
HerstellerAEMC-INSTRUMENTE

9. Garantieinformationen

AEMC INSTRUMENTS products are designed and manufactured to the highest quality standards. For specific warranty terms and conditions applicable to your Model 6255 Micro-Ohmmeter, please refer to the warranty card included with your product or visit the official AEMC INSTRUMENTS webWebsite. Garantien decken in der Regel Material- und Verarbeitungsfehler bei normalem Gebrauch ab.

Bitte bewahren Sie Ihren Kaufbeleg für eventuelle Garantieansprüche auf.

10. Kundendienst

For technical assistance, service, or repair of your AEMC Model 6255 Micro-Ohmmeter, please contact AEMC INSTRUMENTS customer support.

When contacting support, please have your instrument's model number (6255) and serial number ready.

Zugehörige Dokumente - 6255

Vorview AEMC Digital FlexProbe 400D/4000D Serie – Benutzerhandbuch – Wechselstrommessung
Benutzerhandbuch für die AEMC Digital FlexProbe Modelle 400D-6, 400D-10, 4000D-14 und 4000D-24. Zu den Merkmalen gehören TRMS-Wechselstrommessung, CAT IV-Klassifizierung, flexibler Sensorbetrieb und detaillierte Spezifikationen für elektrische, umweltbedingte und mechanische Parameter.
Vorview AEMC Digital FlexProbe Benutzerhandbuch: Modelle 400D-6, 400D-10, 4000D-14, 4000D-24
Ausführliches Benutzerhandbuch für Wechselstrommessgeräte der AEMC Digital FlexProbe-Serie (Modelle 400D-6, 400D-10, 4000D-14, 4000D-24) mit detaillierten Produktinformationen, Bedienung, Spezifikationen, Sicherheitsvorkehrungen und Wartungsverfahren.
Vorview AEMC PEL 52 Power & Energy Logger User Manual
User manual for the AEMC PEL 52 Power & Energy Logger, detailing its features, specifications, operation, setup, maintenance, and troubleshooting for electrical measurements in single-phase and two-phase distribution networks.
Vorview AEMC 2620 Fehlerstrom-/Leckstromdetektor mit künstlichem Neutralleiter AN-1 – Benutzerhandbuch
Benutzerhandbuch für den AEMC Fehlerstrom-/Leckagedetektor Modell 2620 und das Zubehör AN-1 Künstlicher Neutralleiter mit detaillierten Angaben zu Spezifikationen, Bedienung, Fehlersuche und Wartung.
Vorview AEMC SL361 AC/DC Stromsonde – Benutzerhandbuch
Benutzerhandbuch für die AEMC SL361 AC/DC-Stromsonde mit detaillierten Informationen zu Funktionen, Bedienung, Spezifikationen, Wartung und Garantie.
Vorview AEMC PEL 52 Power & Energy Logger User Manual
User manual for the AEMC PEL 52 Power & Energy Logger, detailing its features, setup, operation, specifications, and maintenance for accurate electrical measurements.