Lumen VC-A50PN

Lumens VC-A50PN NDI, SDI, HDMI 20x HD PTZ Camera User Manual

Modell: VC-A50PN

1. Einleitung

The Lumens VC-A50PN is a high-definition Pan/Tilt/Zoom (PTZ) camera designed for professional video production and streaming applications. It features a 1/2.8-inch image sensor, delivering Full HD 1080p video at 60 frames per second. This camera supports multiple output interfaces including NDI, 3G-SDI, and HDMI, offering versatile connectivity options. Power over Ethernet (PoE+) simplifies installation by providing power, control, and video over a single Ethernet cable. The VC-A50PN is equipped with a 20x optical zoom lens, ensuring clear images even in challenging lighting conditions. Its precise and quiet PTZ mechanism allows for wide shooting angles and smooth camera movements, making it suitable for education, videoconferencing, live broadcasting, and gaming environments.

Lumens VC-A50PN PTZ Camera front view

Abbildung 1: Vorder- und Seitenansicht view of the Lumens VC-A50PN PTZ Camera. This image shows the camera's compact design and lens.

2. Sicherheitshinweise

Please read all instructions carefully before operating the camera. Retain this manual for future reference.

  • Energiequelle: Use only the specified power adapter (DC 12V) or a compliant PoE+ (IEEE 802.3at) network switch.
  • Installation: Install the camera on a stable surface or mount it securely to a ceiling using appropriate hardware. Ensure proper ventilation around the camera.
  • Umfeld: Avoid exposing the camera to moisture, rain, dust, or extreme temperatures. Do not operate near heat sources.
  • Reinigung: Vor der Reinigung die Stromzufuhr unterbrechen. Ein weiches, trockenes Tuch verwenden. Keine flüssigen oder Aerosolreiniger verwenden.
  • Wartung: Versuchen Sie nicht, dieses Produkt selbst zu warten. Überlassen Sie alle Wartungsarbeiten qualifiziertem Servicepersonal.
  • Kabel: Ensure all cables are properly connected and secured to prevent accidental disconnection or damage.

3. Packungsinhalt

Bitte prüfen Sie, ob alle unten aufgeführten Artikel in Ihrem Paket enthalten sind. Sollten Artikel fehlen oder beschädigt sein, kontaktieren Sie bitte umgehend Ihren Händler.

  • Lumens VC-A50PN PTZ Camera
  • Netzteil (DC 12 V)
  • IR-Fernbedienung
  • Mounting Bracket (for ceiling installation)
  • Benutzerhandbuch (dieses Dokument)

4. Produktüberschreitungview

4.1 Kamerafunktionen

  • Full HD 1080p output at 60 fps
  • 20x optisches Zoomobjektiv
  • NDI|HX Technology for low-latency IP video transmission
  • Supports Power over Ethernet (PoE+)
  • Multiple video outputs: HDMI, 3G-SDI, and IP (Ethernet)
  • Wide shooting angles with 340° pan and 120° tilt range
  • Supports SRT (Secure Reliable Transport) protocol
  • Audio input supports AAC encoding with 44.1/48 K sampLing-Frequenz

4.2 Anschlüsse auf der Rückseite

The rear panel of the VC-A50PN camera provides all necessary input and output ports for power, video, audio, and control. Refer to the diagram below for a detailed layout.

Lumens VC-A50PN Rear Panel Connections

Abbildung 2: Ausführlich view of the Lumens VC-A50PN rear panel connections.

  1. Kensington Lock Port: For securing the camera with a compatible lock.
  2. DC-EINGANG 12V: Stromanschluss für das mitgelieferte 12-V-Gleichstromnetzteil.
  3. USB: For firmware updates and service.
  4. AUDIOEINGANG: 3.5mm stereo audio input jack.
  5. ETHERNET (NDI|HX): RJ-45 port for network connection, PoE+ power, NDI video, and IP control.
  6. RS-232 OUT: 8-pin mini-DIN connector for RS-232 serial control output.
  7. RS-232 IN: 8-pin mini-DIN connector for RS-232 serial control input.
  8. HDMI-AUSGANG: HDMI output port for video.
  9. RS-422: 9-pin terminal block for RS-422 serial control.
  10. 3G-SDI: BNC connector for 3G-SDI video output.
  11. OUTPUT SWITCH (DIP Switches): Four DIP switches to configure video output settings. Refer to section 5.3 for details.
  12. IR SELECT: Switch to select the IR remote control address.

5. Einrichtung

5.1 Physische Installation

The VC-A50PN can be installed on a desktop or mounted to a ceiling.

  • Desktop-Installation: Place the camera on a flat, stable surface. Ensure adequate space for ventilation and cable connections.
  • Deckenmontage: Use the provided mounting bracket and hardware. Ensure the ceiling can support the camera's weight. Follow the instructions included with the mounting kit for secure installation.

5.2 Anschlusskabel

Before connecting cables, ensure the camera is powered off.

  1. Stromanschluss:
    • Gleichstrom: Connect the included 12V DC power adapter to the "DC IN 12V" port.
    • PoE+ Power: If using PoE+, connect an Ethernet cable from a PoE+ enabled network switch to the "ETHERNET" port. The camera will receive power through this connection, eliminating the need for the DC power adapter.
  2. Videoausgang:
    • HDMI: Connect an HDMI cable from the "HDMI OUT" port to an HDMI input device (e.g., monitor, switcher).
    • 3G-SDI: Connect a 3G-SDI cable from the "3G-SDI" port to an SDI input device.
    • IP (NDI|HX): Connect an Ethernet cable from the "ETHERNET" port to your network. The NDI|HX video stream will be available over the network.
  3. Audioeingang: Connect an audio source (e.g., microphone, mixer) to the "AUDIO IN" 3.5mm jack.
  4. Steueranschlüsse:
    • RS-232: Connect a serial control cable to the "RS-232 IN" port for external control. The "RS-232 OUT" port can be used for daisy-chaining.
    • RS-422: Connect a serial control cable to the "RS-422" terminal block for external control.
    • IP-Steuerung: The camera can also be controlled via IP commands over the Ethernet connection.

5.3 Output Switch (DIP Switches) Configuration

The four DIP switches on the rear panel (labeled "OUTPUT SWITCH") are used to configure specific video output settings. Refer to the table below for common configurations. Ensure the camera is powered off before changing DIP switch settings.

Lumens VC-A50PN I/O Connections Diagram with DIP switches

Figure 3: I/O Connections Diagram highlighting the OUTPUT SWITCH DIP switches.

Schalter 1Schalter 2Schalter 3Schalter 4Funktion/Einstellung
AUSAUSAUSAUSDefault (e.g., 1080p/60)
ONAUSAUSAUS1080p/59.94
AUSONAUSAUS1080p/50
ONONAUSAUS1080i / 60
AUSAUSONAUS720p/60
............(Consult full manual for all DIP switch combinations)

6. Bedienungsanleitung

6.1 Ein-/Ausschalten

  • Einschalten: Connect the power adapter or PoE+ Ethernet cable. The camera will initiate its startup sequence.
  • Ausschalten: Disconnect the power adapter or PoE+ Ethernet cable.

6.2 PTZ-Steuerung

The camera can be controlled via the IR remote control, RS-232/RS-422 serial commands, or IP control software.

  • Schwenken/Neigen: Use the directional controls on your remote or software to move the camera horizontally (pan) and vertically (tilt). The camera offers 340° pan and 120° tilt.
  • Zoom: Use the zoom controls to adjust the 20x optical zoom.
  • Fokus: The camera supports auto-focus. Manual focus adjustment may be available via control software.
  • Voreinstellungen: The camera supports up to 128 preset positions. You can save and recall specific pan, tilt, and zoom settings for quick camera positioning.

6.3 Videoausgang

The VC-A50PN simultaneously outputs video via HDMI, 3G-SDI, and IP (NDI|HX).

  • HDMI/3G-SDI: Connect these outputs to your video switcher, monitor, or recording device. The resolution and frame rate are determined by the DIP switch settings and camera configuration.
  • NDI|HX: Once connected to a network, the NDI|HX stream will be discoverable by NDI-compatible software and hardware on the same network.

6.4 Network Configuration (IP Control & NDI)

For IP control and NDI functionality, the camera needs to be connected to a network. The camera typically obtains an IP address via DHCP by default. You can access the camera's web Schnittstelle durch Eingabe ihrer IP-Adresse in a web browser for advanced settings, including static IP configuration, NDI settings, and image adjustments.

  • Finding the IP Address: Use a network scanner tool or the camera's OSD (On-Screen Display) menu (if available via HDMI/SDI output) to find the camera's current IP address.
  • Web Schnittstelle: Öffnen Sie ein web browser and enter the camera's IP address to access its configuration page.
  • NDI Discovery: NDI-enabled applications (e.g., OBS, vMix, Wirecast) will automatically detect the VC-A50PN on the network.

7. Wartung

7.1 Reinigung der Kamera

Vor der Reinigung sicherstellen, dass die Kamera ausgeschaltet und von allen Stromquellen getrennt ist.

  • Kameragehäuse: Use a soft, dry cloth to wipe the camera body. Do not use abrasive cleaners, waxes, or solvents.
  • Linse: Gently clean the lens with a lens cleaning cloth and a specialized lens cleaning solution. Avoid touching the lens surface with your fingers.

7.2 Firmware-Updates

Periodically check the Lumens official website for available firmware updates. Firmware updates can improve performance, add new features, or fix bugs. Follow the instructions provided with the firmware update package carefully.

8. Fehlerbehebung

If you encounter issues with your VC-A50PN camera, refer to the following common problems and solutions:

ProblemMögliche UrsacheLösung
Kein StromPower adapter not connected; PoE+ not active or faulty cable.Ensure power adapter is securely connected and outlet is live. If using PoE+, verify the network switch port is PoE+ enabled and the Ethernet cable is functional.
Kein Videoausgang (HDMI/SDI)Incorrect cable connection; wrong DIP switch settings; display input not selected.Check HDMI/SDI cable connections. Verify DIP switch settings match desired output resolution/frame rate. Ensure your display/switcher is set to the correct input.
No NDI stream detectedNetwork issue; camera not powered; firewall blocking NDI.Ensure camera is powered and connected to the network. Verify the camera has an IP address. Check network firewall settings on your computer/network. Ensure NDI is enabled in the camera's web Schnittstelle.
PTZ-Steuerung reagiert nichtIR remote battery low; incorrect control cable; wrong control protocol selected.Replace IR remote batteries. Check RS-232/RS-422 cable connections. Verify the control software/device is configured for the correct protocol (VISCA, PELCO D/P, NDI).
Image quality issues (blurry, dark, overexposed)Lens dirty; incorrect exposure/white balance settings.Clean the lens. Adjust exposure, white balance, and gain settings via the camera's web interface or control software.

If the problem persists after trying these solutions, please contact Lumens technical support.

9. Spezifikationen

Below are the detailed technical specifications for the Lumens VC-A50PN PTZ Camera.

BesonderheitDetail
ModellnameVC-A50PN
Bildsensor1/2.8" 2MP CMOS
Videoausgabeauflösung1080p (60/59.94/50/30/29.97/25 fps), 1080i (60/59.94/50 fps), 720p (60/59.94/50 fps)
Optischer Zoom20x
Schwenk-/NeigebereichPan: -170° to +170° (Total 340°); Tilt: -30° to +90° (Total 120°)
Video-AusgabeschnittstellenHDMI, 3G-SDI, Ethernet (NDI|HX)
VideokomprimierungMJPEG, H.264 / SVC
StromquelleDC 12V or PoE+ (IEEE 802.3at)
SteuerschnittstellenRS-232, RS-422, Ethernet (IP Control)
KontrollprotokollVISCA, PELCO D/P, NDI
Mindestbeleuchtung1.0 Lux (F1.6, 50IRE, 30fps)
Verschlusszeit1/1 ~ 1/10,000 Sek
Brennweitef = 4.7 ~ 94 mm
Abmessungen (B x H x T)174 x 186 x 187M (6.9 x 7.3 x 7.3 Zoll)
Gewicht2 kg
FarbeWeiß
Betriebstemperatur0 °C bis 40 °C (32 °F bis 104 °F)

10. Garantie und Support

10.1 Garantieinformationen

Lumens products are designed for reliability and performance. For detailed warranty terms and conditions, please refer to the warranty card included with your product or visit the official Lumens website. The warranty typically covers defects in materials and workmanship under normal use for a specified period from the date of purchase.

10.2 Technischer Support

If you require technical assistance or have questions regarding the operation or maintenance of your Lumens VC-A50PN camera, please contact Lumens technical support. Before contacting support, please have your product model number (VC-A50PN) and serial number ready. You can find contact information on the official Lumens webWebsite.

  • Online-Ressourcen: Visit the Lumens website for FAQs, drivers, firmware updates, and additional documentation.
  • Kontaktinformationen: Refer to the Lumens website for phone numbers, email addresses, and support hours for your region.

Zugehörige Dokumente - VC-A50PN

Vorview Lumens VC-A50PN 高清攝像機 使用手冊
本使用手冊提供 Lumens VC-A50PN PTZ視訊攝影機的詳細資訊,涵蓋安裝、操作、網路設定和故障排除。了解如何最大化您的 VC-A50PN的功能,以進行專業影片製作和廣播.
Vorview Lumens VC-B30U PTZ Video Camera - Full HD 1080p, 12x Optical Zoom
Detailed specifications and features of the Lumens VC-B30U PTZ Video Camera, including its 1080p resolution, 12x optical zoom, USB 3.0 and HDMI outputs, and suitability for conference rooms.
Vorview Lumens VC-TR41 Quick Installation Guide
A concise guide for setting up the Lumens VC-TR41 PTZ camera, detailing connections, video output options (HDMI, SDI, USB, Network), IP configuration, tracking features, and advanced Smart Framing technology.
Vorview Lumens VC-A53 PTZ-Videokamera – Benutzerhandbuch
Ausführliches Benutzerhandbuch für die Lumens VC-A53 PTZ-Videokamera, das Installation, Einrichtung, Netzwerkfunktionen, Fehlerbehebung und Sicherheitshinweise umfasst.
Vorview Lumens VC-TR61 4K AI Auto-Tracking 30x Zoom PTZ-Kamera – Produktspezifikationen
Detaillierte Spezifikationen und Funktionen der Lumens VC-TR61, einer 4K AI Auto-Tracking 30x Zoom PTZ-Kamera, einschließlich Videoausgänge, Tracking-Modi, Anschlussmöglichkeiten und technische Daten.
Vorview Lumens VC-TR40/VC-TR40N Firmware Release Notes
This document details the firmware release history for the Lumens VC-TR40 and VC-TR40N cameras, including new features, bug fixes, and improvements for various versions.