1. Einleitung
The Uni-T UT18D is a versatile automatic range voltage tester designed for measuring AC and DC voltage, including three-phase AC current. It features three-phase AC power indicator phase, RCD testing, single-pole measurement (to identify live/neutral lines), self-check, and battery-free detection capabilities. This device is suitable for professional electricians and DIY enthusiasts for various electrical testing needs.

Figure 1: Uni-T UT18D Voltage Tester with highlighted features.
2. Sicherheitshinweise
Always adhere to local and national safety regulations when working with electrical systems. This device is rated CAT III 690V and CAT IV 600V, and has an IP65 waterproof rating, ensuring safety under specified conditions. However, proper precautions must always be taken.
- Gehen Sie immer davon aus, dass Stromkreise unter Spannung stehen, bis das Gegenteil bewiesen ist.
- Wear appropriate Personal Protective Equipment (PPE), such as insulated gloves and safety glasses.
- Verwenden Sie das Gerät nicht, wenn es beschädigt erscheint oder nicht ordnungsgemäß funktioniert.
- Überschreiten Sie nicht die maximale LautstärketagDie für das Gerät angegebenen e-Werte.
- Ensure the test probes are securely connected and in good condition before use.

Figure 2: Safety certifications and dimensions of the UT18D.
3. Produktüberschreitungview
The UT18D features a robust design with clear indicators for ease of use. Key components include:
- Test Pen Caps: Protective covers for the test probes.
- Test Pens L1 & L2: Probes for making electrical contact.
- Taschenlampe: Integriertes Licht zur Ausleuchtung dunkler Arbeitsbereiche.
- Bandtage Indication (LED): LED bar graph for quick voltage level reference.
- LCD Anzeige: Large screen for precise voltage readings and other information.
- RCD-Testtaste: Startet den Fehlerstromschutzschaltertest.
- Flashlight/Self-Inspection Button: Activates the flashlight and performs self-inspection.
- Hold Mode/Backlight Button: Freezes the display reading; long press activates backlight.
- Batterieabdeckung: Access point for battery replacement.

Figure 3: Labeled components of the UT18D.
4. Einrichtung
4.1 Einlegen der Batterie
The UT18D requires 2 AAA batteries for operation. These batteries are typically not included with the device.
- Suchen Sie die Batterieabdeckung auf der Rückseite des Geräts.
- Öffnen Sie die Batterieabdeckung mit einem Schraubendreher.
- Legen Sie 2 AAA-Batterien ein und achten Sie dabei auf die richtige Polarität (+/-).
- Schließen Sie die Batterieabdeckung sicher.
The device features an automatic power-off function to conserve battery life and can perform basic voltage detection without batteries, though full functionality like continuity testing requires them.
5. Bedienungsanleitung
5.1 AC/DC-Voltage Messung
The UT18D automatically detects AC/DC voltage innerhalb des Spannungsbereichs von 12 V bis 690 V.
- Remove the protective caps from the test probes.
- Schließen Sie die Messspitzen an den Stromkreis oder das Bauteil an, das Sie messen möchten.
- Die voltage level will be displayed on the LCD, and the corresponding LEDs will illuminate.
5.2 Durchgangstest
The continuity test function requires batteries to be inserted and in good condition. Ensure the circuit under test is not live.
- Stellen Sie sicher, dass der Stromkreis spannungsfrei ist.
- Schließen Sie die Prüfspitzen an die Schaltung oder das Bauteil an.
- A buzzer will sound, and an LED will illuminate to confirm continuity.

Abbildung 4: Durchführung eines Durchgangstests.
5.3 RCD Test (Residual Current Device)
The RCD test function detects leakage protective switches. This function should NOT be used in 110V electrical systems.
- Connect the test probes to the circuit where an RCD is present.
- Press the RCD test button.
- Observe if the RCD trips, indicating proper function.

Figure 5: Performing an RCD test.
5.4 Phase Sequence Test
Dieses Gerät kann die Phasendrehung innerhalb eines dreiphasigen Netzes bestimmen.
- Connect the test probes to the three-phase lines as indicated by the device or diagram.
- The display will indicate the phase rotation (e.g., R for clockwise, L for counter-clockwise).

Figure 6: Phase Rotation Test procedure.
5.5 Single-Pole Measurement
The single-pole measurement allows identification of live or neutral lines using a single probe.
- Touch one test probe to the conductor.
- The device will indicate if the line is live (phase) or neutral.
5.6 Taschenlampe und Hintergrundbeleuchtung
Activate the built-in flashlight by pressing the dedicated button to illuminate dark work areas. A long press of the Hold button may activate the LCD backlight for improved visibility in low light conditions.

Figure 7: Flashlight feature in use.
6. Wartung
To ensure the longevity and accuracy of your UT18D voltage tester, follow these maintenance guidelines:
- Reinigung: Reinigen Sie das Gerät mit einem trockenen, weichen Tuch. Verwenden Sie keine Scheuermittel oder Lösungsmittel.
- Lagerung: Bewahren Sie das Gerät an einem kühlen, trockenen Ort auf, schützen Sie es vor direkter Sonneneinstrahlung und extremen Temperaturen.
- Batteriewechsel: Replace batteries promptly when the low battery indicator appears on the LCD. Remove batteries if the device will not be used for an extended period.
- Wasserbeständigkeit: The UT18D has an IP65 waterproof rating, providing protection against dust and water jets. While it is resistant, avoid submerging the device or exposing it to high-pressure water.

Abbildung 8: Wasserdichtigkeit gemäß IP65.
7. Fehlerbehebung
If you encounter issues with your UT18D, consider the following:
- Gerät lässt sich nicht einschalten: Prüfen Sie, ob die Batterien richtig eingesetzt sind und ausreichend geladen sind. Tauschen Sie die Batterien gegebenenfalls aus.
- Inkonsistente Messwerte: Ensure proper contact between the test probes and the circuit. Verify that the circuit conditions are within the device's specified operating range.
- Keine Kontinuitätsanzeige: Confirm that batteries are installed and in good condition. Ensure the circuit is de-energized before testing continuity.
For persistent issues, refer to the detailed specifications or contact customer support.
8. Spezifikationen
| Besonderheit | Spezifikation |
|---|---|
| Hersteller | EINHEIT |
| Modellnummer | UT18D |
| Maße | 25 x 23 x 25 cm; 450 g |
| Batterien | 2 AAA (required, not included) |
| Bandtage Reichweite | 12V~690V AC/DC |
| Sicherheitsbewertung | CAT III 690 V, CAT IV 600 V |
| IP-Schutzart | IP65 Wasserdicht |
| Messtyp | Voltmeter |
| Minimales Betriebsvolumentage | 6 Volt |
| Maximale Betriebslautstärketage | 690 Volt |
| UPC | 842155122882 |
9. Garantie und Support
For warranty information, technical support, or service inquiries, please contact Uni-T customer service directly or visit the official Uni-T webBewahren Sie Ihren Kaufbeleg als Kaufnachweis für Garantieansprüche auf.