Dynascan DYNASCAN P-72

Dynascan P-72 Dualband-Mobilfunkgerät – Benutzerhandbuch

Model: DYNASCAN P-72

1. Einführung und Endeview

The Dynascan P-72 is an advanced dual-band mobile amateur radio transceiver designed for reliable communication across VHF and UHF frequencies. Its compact size and robust feature set make it ideal for various amateur radio applications. This manual provides comprehensive instructions for the proper setup, operation, and maintenance of your Dynascan P-72.

Hauptmerkmale:

2. Packungsinhalt

Please check the box carefully to ensure all items are present and in good condition:

Dynascan P-72 radio, handheld microphone, mounting bracket, and power cable

Abbildung 2.1: Dynascan P-72 package contents, including the main transceiver unit, handheld speaker microphone, mounting bracket, and power cable.

3. Einrichtung

Follow these steps to set up your Dynascan P-72 for initial operation.

3.1 Anschließen des Mikrofons

Connect the coiled cable of the handheld speaker microphone to the dedicated jack on the side of the transceiver unit. Ensure the connector is fully inserted to establish a secure connection.

3.2 Stromanschluss

Connect the supplied DC power cable to the power input on the rear of the transceiver. Connect the other end of the power cable to a stable 13.8 VDC power source capable of supplying sufficient current (e.g., a regulated power supply or vehicle battery). Observe correct polarity (red for positive, black for negative).

3.3 Antennenanschluss

Connect a suitable 50 Ohm dual-band antenna (VHF/UHF) to the antenna connector on the rear of the transceiver. Ensure the connection is tight and secure. Never transmit without an antenna connected, as this can damage the transceiver.

Dynascan P-72 radio with connected handheld microphone, displaying frequencies on screen

Abbildung 3.1: The Dynascan P-72 transceiver with its handheld speaker microphone connected, showing the main display.

4. Bedienungsanleitung

This section details the basic operation of your Dynascan P-72.

4.1 Ein-/Ausschalten

Zum Einschalten des Geräts die Taste gedrückt halten LEISTUNG button (usually located on the front panel or microphone). To power off, press and hold the same button again.

4.2 Lautstärke- und Rauschsperreneinstellung

4.3 Frequency Selection (VFO Mode)

In VFO (Variable Frequency Oscillator) mode, you can directly input or tune to desired frequencies.

  1. Drücken Sie die VFO/MR button to switch to VFO mode.
  2. Use the main tuning knob on the transceiver or the up/down arrows on the microphone to adjust the frequency.
  3. Alternatively, use the DTMF keypad on the microphone to directly enter the desired frequency.

4.4 Channel Operation (Memory Mode)

The P-72 supports 255 memory channels for storing frequently used frequencies and settings.

  1. Drücken Sie die VFO/MR button to switch to Memory mode.
  2. Use the tuning knob or up/down arrows to scroll through stored memory channels.
  3. Refer to the full manual for detailed instructions on storing and deleting memory channels.

4.5 Transmission (PTT)

Zum Senden die Taste gedrückt halten PTT (Push-to-Talk) button on the side of the handheld microphone. Speak clearly into the microphone. Release the PTT button to return to receive mode.

4.6 Dual Frequency Reception and Full Duplex

The Dynascan P-72 can receive two frequencies simultaneously (VHF and UHF). It also supports full duplex operation, allowing you to transmit on one band while receiving on another.

Abgewinkelt view of Dynascan P-72 radio with microphone, showing the display and controls

Abbildung 4.1: Abgewinkelt view of the Dynascan P-72, highlighting the display and control knobs.

5. Wartung

Proper maintenance ensures the longevity and optimal performance of your Dynascan P-72.

5.1 Reinigung

Wipe the transceiver and microphone with a soft, dry cloth. For stubborn dirt, use a slightly damp Mit einem milden Seifentuch abwischen und anschließend trockenreiben. Verwenden Sie keine scharfen Chemikalien, Lösungsmittel oder Scheuermittel.

5.2 Speicherung

When not in use for extended periods, store the unit in a cool, dry place away from direct sunlight, extreme temperatures, and excessive dust. Disconnect the power cable and antenna.

5.3 Antenna and Cable Care

Regularly inspect antenna connections and cables for any signs of wear, damage, or corrosion. Ensure all connections remain tight to prevent signal loss and potential damage to the transceiver.

6. Fehlerbehebung

If you encounter issues with your Dynascan P-72, refer to the following common problems and solutions.

ProblemMögliche UrsacheLösung
Kein StromNetzkabel nicht angeschlossen; falsche Lautstärketage; Sicherung durchgebrannt.Check power cable connection; verify power supply voltage (13.8 VDC); check inline fuse on power cable.
No Audio / Weak AudioVolume too low; squelch set too high; microphone not connected properly.Increase volume; lower squelch level; ensure microphone is fully inserted.
Übertragung nicht möglichAntenna not connected; PTT button faulty; frequency out of band.Connect antenna securely; test PTT button; ensure frequency is within 144-146 MHz or 430-440 MHz.
Schlechter EmpfangAntenna issue; high interference; squelch too high.Check antenna connection and condition; move away from interference sources; lower squelch.
Tastatur gesperrtTastensperre aktiviert.Refer to the manual for the specific key combination to unlock the keypad.

For issues not listed here, or if troubleshooting steps do not resolve the problem, please contact your dealer or a qualified service technician.

7. Spezifikationen

Detailed technical specifications for the Dynascan P-72.

BesonderheitSpezifikation
ModellnummerDYNASCAN P-72
FrequenzbereichVHF: 144–146 MHz, UHF: 430–440 MHz
Sendeleistung20 Watt
Anzahl der Kanäle255
Frequenzschritte5, 6.25, 10, 12.5, 25, 50, 100 kHz
Tuner-TechnologieUHF, VHF
Bandtage13.8 V Gleichstrom
Antennenimpedanz50 Ohm
Audioausgang2 Watt
Abmessungen (ca.)121.5 x 66.5 x 42.5 mm
Gewicht ca.)550 g (with microphone)
FarbeSchwarz
SonderfunktionenKeypad Lock, Compact Design

8. Garantie und Support

The Dynascan P-72 is manufactured by Pihernz Comunicaciones. For warranty information and technical support, please refer to the documentation provided with your purchase or contact your authorized dealer. Keep your proof of purchase for any warranty claims.

Zugehörige Dokumente - DYNASCAN P-72

Vorview DYNASCAN LP-66 VHF-FM PMR Handfunkgerät – Benutzerhandbuch
Ausführliches Benutzerhandbuch für das DYNASCAN LP-66 VHF-FM PMR Handfunkgerät. Es behandelt Einrichtung, Bedienung, Funktionen, technische Daten und Fehlerbehebung. Enthält detaillierte Menüerklärungen und Informationen zur Einhaltung der Vorschriften.
Vorview Dynascan R-58 PMR-446 Tragbares Transceiver-Benutzerhandbuch
Umfassendes Benutzerhandbuch für den tragbaren Transceiver Dynascan R-58 PMR-446 mit Informationen zu Funktionen, Betrieb, Wartung, Sicherheitsvorkehrungen und technischen Daten. Verfügbar auf Spanisch und Englisch.
Vorview DynaScan DS552LT6-1 Benutzerhandbuch: Installation, Betrieb und Spezifikationen
Umfassendes Benutzerhandbuch für das professionelle LCD-Display DynaScan DS552LT6-1 mit Informationen zu Installation, Betrieb, Sicherheitsvorkehrungen, Fehlerbehebung und technischen Daten.
Vorview DynaScan DS323LT4 32" Clean Back Digital Signage Benutzerhandbuch
Benutzerhandbuch für das 32-Zoll-Clean-Back-Digital-Signage-Display DynaScan DS323LT4. Behandelt Installation, Betrieb, Sicherheit, Fehlerbehebung und Spezifikationen für den professionellen Einsatz.
Vorview DynaScan Premium Visual Solutions Product Catalog
Explore DynaScan's comprehensive range of premium visual solutions, including ultra-high brightness LCD displays for indoor and outdoor applications, specialized window-facing displays, and robust outdoor kiosks. Discover advanced technology for sunlight readability, durability, superior color reproduction, and versatile installation options.
Vorview Bedienungsanleitung für Midland ML3215 / ML3245
This document provides comprehensive operating instructions for the Midland ML3215 and ML3245 two-way radios. It covers setup, radio functions, scan modes, menu settings, DTMF microphone operation, licensing, service, maintenance, and warranty information. Designed for occupational use, it details FCC compliance requirements and safe operation.