Hilitand YYB-5

Hilitand YYB-5 12V/24V Forward/Reverse Motor Control Board User Manual

1. Einleitung

This manual provides comprehensive instructions for the Hilitand YYB-5 Two-Relay Timing Module. This versatile control board is designed for precise control of various electrical loads, including forward/reverse motor operations, solenoid valves, pumps, and lighting systems. It features a wide time range and robust power output capabilities, making it suitable for a multitude of industrial and hobbyist applications.

Abgewinkelt view of the Hilitand YYB-5 module

Abbildung 1: Schräg view of the Hilitand YYB-5 module, showing the relays, terminal blocks, display, and control buttons.

2. Hauptmerkmale

  • Types of Functions: The module features 6 types of commonly used functions to meet the requirements of various applications.
  • Breite Anwendung: The control board can manage 2-way solenoid valves, pumps, motors, lights, and other freely operating loads.
  • Zeitspanne: The module's time range extends from 0.1 seconds to 999 minutes, adjustable at any time.
  • Leistungsabgabe: The motor control board can manage DC or AC loads up to 30A.
  • Good Performance: The module offers good performance, is easy to install, and has a long service life.
Hilitand YYB-5 Motor Relay Delay Module highlighting 6 functions

Abbildung 2: Überview image of the Hilitand YYB-5 Motor Relay Delay Module, emphasizing its 6 types of commonly used functions.

3. Technische Daten

SpezifikationWert
MarkeHilitand
ModellnummerYYB-5 (Manufacturer Reference: Hilitandn7e1ipg8s4)
Produktabmessungen (L x B x H)9.5 x 9 x 2.5 cm; 100 Gramm
Leistung810 Watt
Artikel im Paket1
Konforme SpezifikationenDC
Batterien im Lieferumfang enthaltenNEIN
Batterien erforderlichNEIN
UrsprungslandChina
SteckertypSchraubklemmen
KontaktmaterialSilver or Copper
KontakttypNormalerweise geschlossen
Aktuelle Bewertung30 A
BetriebsartAutomatisch
UPC748018581561
ASINB07QCS3D6V
Dimensional drawing of the Hilitand YYB-5 motor control board

Figure 3: Dimensional drawing of the Hilitand YYB-5 motor control board, showing length, width, and height in millimeters and inches.

4. Aufbau und Verkabelung

Proper wiring is crucial for the safe and correct operation of the YYB-5 module. Always ensure the power supply is disconnected before making any connections.

4.1 Stromversorgungsanschluss

Connect your 12V or 24V DC power supply to the designated terminals on the module. Observe correct polarity (positive to '+' and negative to '-'). The module supports both 12V and 24V DC input.

4.2 Load Connections (Motor, Solenoid, Lights)

The module features two independent relays, each with Common (COM), Normally Open (NO), and Normally Closed (NC) terminals. These allow for flexible control of various loads, including forward/reverse motor applications.

  • Motorsteuerung: For forward/reverse motor control, connect the motor to the relay outputs as shown in Figure 4. This configuration allows the module to switch the motor's direction.
  • General Loads: For other loads like solenoid valves or lights, connect the load to the COM and either NO or NC terminals of a relay, depending on whether you want the load to be ON when the relay is activated (NO) or OFF (NC).
Wiring diagram for connecting a motor to the Hilitand YYB-5 module

Figure 4: Wiring diagram for connecting a motor to the Hilitand YYB-5 module, illustrating power supply, load 1, load 2, and motor connections.

Detailed wiring diagram for the Hilitand YYB-5 module

Figure 5: Detailed wiring diagram for the Hilitand YYB-5 module, showing connections for DC/AC power, signal/button inputs, and relay outputs (COM, NO, NC) for two loads.

4.3 Signaleingang

The module may include terminals for external signal inputs or buttons (e.g., IN1, IN2, IN3, GND) to trigger specific functions or modes. Refer to the detailed programming guide for specific connections related to these inputs.

5. Bedienungsanleitung

The Hilitand YYB-5 module is highly programmable, offering 6 distinct operating modes. Programming is typically done via the onboard display and buttons (SET, +, -, KEY).

5.1 Modulfunktionen

The 6 functions allow for various timing and control scenarios, such as delay ON, delay OFF, cycle timing, and more complex sequences for motor control. Each function will have specific parameters to set (e.g., time duration, number of cycles).

Hilitand YYB-5 module controlling solenoid valves, pumps, motors, and lights

Figure 6: Image of the Hilitand YYB-5 module highlighting its capability to control 2-way solenoid valves, pumps, motors, and lights.

5.2 Programming the Module

While specific programming steps vary by function, the general process involves:

  1. Programmiermodus aufrufen: Press and hold the 'SET' button until the display changes, indicating entry into programming mode.
  2. Funktion auswählen: Use the '+' and '-' buttons to cycle through the available functions (e.g., P-1, P-2, etc.). Press 'SET' to confirm your selection.
  3. Parameter einstellen: For the selected function, use the '+' and '-' buttons to adjust time values (e.g., ON time, OFF time) or other parameters. The 'KEY' button might be used to switch between setting different parameters or digits.
  4. Einstellungen speichern: Once all parameters are set, press and hold the 'SET' button again to save the configuration and exit programming mode.

For detailed instructions on each of the 6 functions and their specific parameter settings, please refer to the comprehensive programming guide available from the manufacturer or product support resources.

6. Wartung

The Hilitand YYB-5 module is designed for long-term reliability with minimal maintenance. Follow these guidelines to ensure optimal performance:

  • Sauber und trocken halten: Protect the module from dust, dirt, and moisture. Avoid operating in environments with excessive humidity or corrosive substances.
  • Verbindungen prüfen: Überprüfen Sie regelmäßig alle Kabelverbindungen auf festen Sitz und Korrosionsfreiheit. Lose Verbindungen können zu Funktionsstörungen oder Schäden führen.
  • Vermeiden Sie körperliche Erschütterungen: Gehen Sie vorsichtig mit dem Modul um, um physische Schäden zu vermeiden.
  • Belüftung: Ensure adequate airflow around the module, especially if operating at higher loads, to prevent overheating.

7. Fehlerbehebung

If you encounter issues with your Hilitand YYB-5 module, consider the following troubleshooting steps:

  • Modul lässt sich nicht einschalten:
    • Überprüfen Sie die Lautstärke der Stromversorgungtage (12V or 24V DC) is correct.
    • Check power supply connections for correct polarity and secure contact.
    • Stellen Sie sicher, dass die Stromversorgung funktionsfähig ist.
  • Laden lässt sich nicht aktivieren/deaktivieren:
    • Check the wiring of the load to the relay terminals (COM, NO, NC).
    • Verify the load itself is functional and within the module's 30A current rating.
    • Review the programmed function and parameters to ensure they match your desired operation.
  • Falsches Timing:
    • Re-enter programming mode and verify all time settings.
    • Ensure the time unit (seconds, minutes) is correctly configured if applicable.
  • Tasten reagieren nicht:
    • Stellen Sie sicher, dass das Modul ordnungsgemäß mit Strom versorgt wird.
    • Drücken Sie die Tasten vorsichtig, um sicherzustellen, dass sie nicht klemmen.

If problems persist after following these steps, please contact Hilitand customer support for further assistance.

8. Garantie und Support

For information regarding product warranty, returns, or technical support, please refer to the documentation provided at the time of purchase or contact Hilitand directly through their official website or customer service channels. Please have your product model (YYB-5) and ASIN (B07QCS3D6V) available when seeking support.

Zugehörige Dokumente - YYB-5

Vorview Hilitand 9595W 60X Mini Microscope with UV Detector - Product Overview
Detailed specifications and features of the Hilitand 9595W, a portable 60X mini microscope with UV currency detection capabilities, LED illumination, and a clip-on design for various inspection tasks.
Vorview 5G Mobile Hotspot WiFi 6 Portable Router with SIM Card Slot - 6100mAh Battery
Überview of the 5G Mobile Hotspot WiFi 6 Portable Router. Features high-speed 5G connectivity, WiFi 6, IP67 rating, a 6100mAh battery, and supports up to 16 devices. Ideal for home and travel use.
Vorview Pneumatische Ventile der Serie Airtec ICK-09: Technische Daten und Zubehör
Detaillierte technische Daten, Bestellcodes, Abmessungen und Zubehörinformationen für die pneumatischen Niedertemperaturventile der Airtec ICK-09-Serie, einschließlich 5/2- und 5/3-Wege-Optionen.
Vorview AGS-GSV Gas Solenoid Valve: Installation and Maintenance Guide
Comprehensive installation and maintenance instructions for the AGS-GSV Gas Solenoid Valve by American Gas Safety. Covers specifications, dimensions, capacity, pressure drop, installation, electrical connections, and coil care.
Vorview SMC 5 Port Solenoid Valve Series S0700: Technical Specifications and Features
Explore the SMC 5 Port Solenoid Valve Series S0700, featuring plug lead type, body ported and base mounted options. Discover detailed specifications, variations, ordering information, and technical data for industrial automation applications.
Vorview SMC VQC2201NR-5-X27 / VQC4201R-5-X17 External Pilot Solenoid Valve Instruction Manual
Instruction manual for SMC's VQC2201NR-5-X27 and VQC4201R-5-X17 external pilot solenoid valves, covering safety, specifications, installation, settings, maintenance, and limitations of use for actuator control.