1. Produktüberschreitungview
The WAGO 284-681 is a 3-conductor through terminal block designed for reliable electrical connections. This terminal block facilitates secure wiring within control cabinets and industrial applications, offering a compact and efficient solution for distributing electrical potential.
Key features include its DIN rail mount compatibility and screw-type connection, ensuring robust and stable installations.

Abbildung 1: Querschnitt view of the WAGO 284-681 3-Conductor Through Terminal Block, showing the internal spring clamp mechanism and conductor pathways. The grey housing encases the metallic current bar and the spring-loaded clamping units for secure wire termination.
2. Sicherheitshinweise
Lesen Sie vor Installation und Inbetriebnahme alle Anweisungen sorgfältig durch. Die Nichtbeachtung dieser Anweisungen kann zu Stromschlag, Brand oder schweren Verletzungen führen.
- Die Installation darf nur von qualifiziertem Personal durchgeführt werden.
- Vor Arbeiten an elektrischen Schaltkreisen unbedingt die Stromzufuhr unterbrechen.
- Geeignete persönliche Schutzausrüstung (PSA) verwenden.
- Verify correct wire gauge and insulation for the application.
- Überschreiten Sie nicht das angegebene Volumentage and current ratings of the terminal block.
- Inspect terminal blocks for damage before installation. Do not use damaged products.
3. Einrichtung und Installation
The WAGO 284-681 terminal block is designed for DIN rail mounting. Follow these steps for proper installation:
- Montage auf DIN-Schiene:
Align the terminal block with the DIN rail. Press the block firmly onto the rail until it clicks into place. Ensure it is securely seated and does not wobble.
- Drahtvorbereitung:
Strip approximately 9-10 mm (0.35-0.39 inches) of insulation from the conductor ends. Ensure the conductor strands are not damaged during stripping.
- Conductor Connection (Screw Type):
Insert the prepared conductor into the designated clamping unit. Use an appropriate screwdriver to tighten the screw firmly. Ensure the conductor is fully seated and the screw is tightened to the recommended torque (refer to technical specifications for exact values, typically found on product packaging or WAGO's official documentation). Gently pull on the wire to confirm a secure connection.
- Testen:
After all connections are made, perform continuity and insulation resistance tests to verify proper wiring and prevent short circuits.
4. Bedienungsanleitung
Once installed and wired, the WAGO 284-681 terminal block functions as a passive component for electrical distribution. No active operation is required beyond ensuring proper connections and adherence to electrical safety standards.
- Bandtage und Strom: Stellen Sie sicher, dass das verwendete Volumentage and current do not exceed the maximum ratings specified for the terminal block.
- Umgebungsbedingungen: Operate the terminal block within its specified environmental conditions (temperature, humidity) to ensure optimal performance and longevity.
5. Wartung
The WAGO 284-681 terminal block is designed for maintenance-free operation under normal conditions. However, periodic inspection is recommended to ensure continued reliability.
- Sichtprüfung: Periodically inspect the terminal blocks for any signs of physical damage, discoloration, or loose connections.
- Verbindungsintegrität: If accessible and safe to do so (with power disconnected), gently check the tightness of screw connections, especially in environments subject to vibration or significant temperature fluctuations.
- Reinigung: If necessary, clean the exterior of the terminal block with a dry, lint-free cloth. Do not use solvents or abrasive cleaners.
6. Fehlerbehebung
Most issues related to terminal blocks stem from improper installation or exceeding operational limits. Refer to the following common issues and solutions:
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Loose connection / Intermittent contact | Insufficient tightening of screw; improper wire stripping; wire pull-out. | Disconnect power. Re-strip wire if necessary. Re-insert and tighten screw to recommended torque. Verify connection by gently pulling the wire. |
| Overheating / Discoloration | Overcurrent; loose connection; environmental factors. | Disconnect power immediately. Check circuit for overcurrent conditions. Inspect connections for looseness. Ensure ambient temperature is within specified limits. Replace damaged terminal block. |
| Schwierigkeiten beim Einführen des Drahtes | Wire gauge too large; screw not sufficiently loosened. | Ensure wire gauge matches terminal block specifications. Loosen the screw completely before attempting to insert the wire. |
If problems persist, consult a qualified electrician or contact WAGO technical support.
7. Technische Daten
The following specifications apply to the WAGO 284-681 3-Conductor Through Terminal Block:
- Modell: 284-681
- Marke: WAGO
- Anzahl der Pole: 3
- Steckertyp: Schrauben
- Montageart: DIN-Schienenmontage
- Spezifikation erfüllt: LÄRM
- ASIN: B07QJB7CTQ
- Hersteller: Wago
- Als Erstes verfügbar: 9. Februar 2020
- Hinweis: Für detaillierte elektrische Nennwerte (Vol.tage, current, wire size range), please refer to the product packaging or official WAGO datasheets.