AUTOOL SDT 100

AUTOOL Kfz-Rauchmelder SDT 100 – Benutzerhandbuch

Brand: AUTOOL | Model: SDT 100

Einführung

The AUTOOL Automotive Smoke Machine Lead Detector SDT 100 is a diagnostic tool designed to quickly and accurately detect leaks in various automotive piping systems. This device utilizes smoke generation to visually identify leaks that may cause performance issues, increased fuel consumption, or engine malfunctions. It features a built-in air pump for convenience and smart protection mechanisms for safe operation.

Produkt überview und Komponenten

The AUTOOL SDT 100 comes with a comprehensive set of accessories to facilitate various leak detection tasks. Below is an overview of the main unit and included components.

AUTOOL SDT 100 Smoke Leak Detector with accessories

Figure 1: AUTOOL SDT 100 Smoke Leak Detector and included accessories. The main unit is yellow and black, accompanied by various hoses, adapters, power cables, and a fluid bottle.

Was ist in der Box:

Technische Daten

BesonderheitSpezifikation
ArbeitstheorieSauerstoffarme Verbrennung
StromversorgungDC 12V-Batterie
Air Pressure OutputEingebaute Luftpumpe
Nennausgangsdruck0.1 MPa bis 0.15 MPa
Nennleistung48 W
Produktgewicht1.6 kg (3.54 Pfund)
Bruttogewicht2.7 kg
Technische Daten10.24 x 7.87 x 7.09 Zoll
AUTOOL SDT 100 Product Specifications and Dimensions

Figure 2: Detailed product specifications and dimensions of the AUTOOL SDT 100 unit.

Installationsanweisungen

  1. Fill with Test Oil: Unscrew the oil filler cap on the top of the unit. Using the provided refill bottle, add 10ml-20ml of test oil (Johnson's baby oil, pink label, is recommended and not included). Do not overfill.
    Filling AUTOOL SDT 100 with test oil

    Figure 3: Adding test oil to the smoke leak detector unit.

  2. Strom anschließen: Connect the power cable with battery clamps to the DC 12V power input on the unit. Attach the red clamp to the positive (+) terminal of your vehicle's 12V battery and the black clamp zum Minuspol (-). Stellen Sie eine sichere Verbindung sicher.
    Connecting AUTOOL SDT 100 to vehicle battery

    Figure 4: Connecting the power clamps to the vehicle's 12V battery.

  3. Attach Smoke Output Hose: Connect one end of the smoke output hose to the "SMOKE OUTPUT" port on the unit.
  4. Install Hanger: Screw the provided hanger into the designated port on the top of the unit for convenient suspension under the vehicle's hood.

Bedienungsanleitung

  1. Fahrzeugsystem vorbereiten: Disconnect the intake pipe of the car or the system you intend to test. Use appropriate adapters to seal the system and connect the smoke output hose.
  2. Einschalten: Flip the "SMOKE SWITCH" to the "ON" position. The "POWER" indicator light will illuminate.
  3. Initiate Smoke Generation: The unit will begin generating smoke. Allow approximately 2 minutes for the smoke to fully fill the pipe system (for small vehicles; larger vehicles may take longer).
  4. Lecks aufspüren: Visually inspect the system for any escaping smoke, which indicates a leak point. Using a flashlight can enhance visibility of the smoke.
    Detecting leaks with smoke from AUTOOL SDT 100

    Figure 5: Smoke escaping from a leak point in an automotive system.

  5. Ausschalten: Once testing is complete, flip the "SMOKE SWITCH" to the "OFF" position and disconnect the power.

EVAP System Detection

For American cars produced after 1996, EVAP service ports are typically located in the engine compartment. Some special models may have them elsewhere.

  1. Locate the EVAP service port and open its plastic cover.
  2. Use a spool wrench to remove the check valve clockwise.
  3. Install the appropriate EVAP service port adapter.
  4. Introduce smoke from the smoke output hose into the EVAP leak detection system through the adapter.

Wide Testing Range and Leakage Examples

The AUTOOL SDT 100 is capable of performing smoke tests on a variety of automotive systems, including:

It is applicable for cars, motorcycles, snowmobiles, off-road vehicles, ATVs, light trucks, and speedboats.

Various types of leaks detectable by AUTOOL SDT 100

Abbildung 6: Visuelles Beispielamples of different automotive systems where leaks can be detected using the smoke machine.

Common Leakage Issues:

Smart Protection Features

The smoke machine is equipped with overheat and freeze protection. If the device operates for an extended period and the temperature exceeds 75°C, it will enter a self-protection state and intelligently power off. The indicator light will turn off, and smoke generation will stop until the temperature returns to a safe level. The built-in air pump can be used to cool the equipment. Do not fill oil while the unit is working.

AUTOOL SDT 100 Overheat and Low Temperature Protection

Figure 7: Visual representation of the overheat (75°C) and low temperature (-20°C) protection features.

Wartung

Fehlerbehebung

Offizielle Produktvideos

AUTOOL SDT 100 Built-in Air Pump Automotive Smoke Machine Lead Detector

This video demonstrates the features and operation of the AUTOOL SDT 100 Smoke Leak Detector, highlighting its built-in air pump and ease of use for automotive diagnostics.

Smoke Machine Automotive Leak Detector

Dieses Video bietet einen allgemeinen Überblickview of an automotive smoke machine leak detector, showcasing its application in identifying leaks within vehicle systems.

Garantie und Support

AUTOOL offers a Drei Jahre Garantie Und Lifelong Maintenance for the SDT 100 Smoke Leak Detector. For damages caused by non-human factors, AUTOOL promises to resend parts for free within 3 years.

For any inquiries or support needs, please contact AUTOOL customer service. They aim to reply as soon as possible within 24 hours.

Zugehörige Dokumente - SDT 100

Vorview AUTOOL SDT205 Rauchmelder Benutzerhandbuch
Ausführliches Benutzerhandbuch für den AUTOOL SDT205 Rauchleckdetektor mit detaillierten Informationen zu Funktionen, Spezifikationen, Bedienung, Wartung und Garantie für die Lecksuche in Kraftfahrzeugen.
Vorview AUTOOL SDT205 Rauchlecksuchgerät – Benutzerhandbuch | Fahrzeugdiagnosegerät
Ausführliches Benutzerhandbuch für den AUTOOL SDT205 Rauchleckdetektor. Erfahren Sie mehr über seine Funktionen, technischen Daten, Bedienung, Wartung und Fehlerbehebung für die professionelle Lecksuche an Fahrzeugen.
Vorview AUTOOL BT70 Batteriekapazitätstester – Benutzerhandbuch – Anleitung zum Testen von 12-V- und 24-V-Autobatterien
Ausführliche Bedienungsanleitung für den AUTOOL BT70 Batteriekapazitätstester. Erfahren Sie, wie Sie 12-V- und 24-V-Bleiakkumulatoren für Autos testen und die Spannungswerte verstehen.tagMesswerte, Statusanzeigen, Sicherheitsvorkehrungen und Wartungsarbeiten für optimale Leistung.
Vorview AUTOOL SDT202 Rauchmelder Benutzerhandbuch
Benutzerhandbuch für den AUTOOL SDT202 Rauchleckdetektor. Enthält detaillierte Anweisungen für Betrieb, Wartung und Fehlerbehebung dieses Kfz-Diagnosetools, das für die effiziente Lecksuche in Fahrzeugen entwickelt wurde.
Vorview AUTOOL SDT206 Rauchleckdetektor Benutzerhandbuch | Kfz-Diagnosetool
Ausführliches Benutzerhandbuch für den AUTOOL SDT206 Rauchleckdetektor. Informieren Sie sich über Funktionen, Bedienung, Sicherheitsvorkehrungen, Wartung und Garantie für eine effiziente Fahrzeuglecksuche.
Vorview AUTOOL SDT205 Rauchmelder Benutzerhandbuch
Dieses Benutzerhandbuch enthält umfassende Anweisungen für den AUTOOL SDT205 Rauchleckdetektor, ein unverzichtbares Diagnosetool für Kraftfahrzeuge zur Erkennung von Lecks in Fahrzeugleitungen. Es deckt das Produkt überview, Funktionen, technische Daten, Betriebsanleitungen, Wartung und Garantieinformationen.