ECOELER YM2108

ECOELER YM2108 In-Wall PIR Motion Sensor Light Switch

Bedienungsanleitung

Einführung

This manual provides detailed instructions for the installation, operation, and customization of your ECOELER YM2108 In-Wall PIR Motion Sensor Light Switch. Please read this manual thoroughly before installation and use to ensure proper function and safety.

Hauptmerkmale:

Sicherheitshinweise

WARNUNG: To prevent severe injury or death from electric shock, always turn off the power at the circuit breaker or fuse box before wiring. It is highly recommended to consult a qualified electrician to determine if you have the proper wiring for this device.

This automatic light switch requires a neutral wire for proper operation. Ensure your electrical setup includes a neutral wire before attempting installation.

Packungsinhalt

Vergewissern Sie sich vor Beginn der Installation, dass alle Komponenten vorhanden sind:

Image showing the ECOELER motion sensor switch, wall plate, screws, and terminal caps.

Figure 1: Included accessories for the ECOELER YM2108 Motion Sensor Switch.

Installation

Befolgen Sie diese Schritte für eine sichere und korrekte Installation:

  1. Strom ausschalten: Locate the circuit breaker or fuse box controlling the light switch you intend to replace. Turn off the power to that circuit. Verify power is off using a voltage Tester.
  2. Alten Schalter entfernen: Carefully remove the existing wall plate and unscrew the old switch from the electrical box. Disconnect the wires from the old switch, noting their connections.
  3. Drähte identifizieren: Identify the Hot (Black), Load (Red), Neutral (White), and Ground (Green or bare copper) wires from your electrical box.
  4. Den neuen Schalter anschließen: Connect the wires from the electrical box to the corresponding wires on the ECOELER YM2108 switch using the provided terminal caps. Ensure all connections are secure.
    • Black wire from box to Black wire on switch (Hot).
    • Red wire from box to Red wire on switch (Load to power light or fan).
    • White wire from box to White wire on switch (Neutral - required).
    • Green or bare copper wire from box to Green wire on switch (Ground).
  5. Montieren Sie den Schalter: Schieben Sie den verdrahteten Schalter vorsichtig in die Anschlussdose. Befestigen Sie ihn mit den mitgelieferten Schrauben.
  6. Wandplatte installieren: Attach the new wall plate over the switch.
  7. Strom wiederherstellen: Schalten Sie den Strom am Leistungsschalter wieder ein.
Wiring diagram for the ECOELER motion sensor switch showing connections for Hot, Load, Neutral, and Ground wires.

Figure 2: Wiring Guide for ECOELER YM2108 Motion Sensor Switch. A neutral wire is required.

Betriebsarten

The ECOELER YM2108 switch offers two primary operation modes: Occupancy (OCC) and Vacancy (VAC). These modes can be selected via a switch located on the device.

Diagram illustrating Occupancy and Vacancy modes on the ECOELER motion sensor switch, with adjustable settings for time, sense, and light.

Figure 3: Operation Modes and adjustable settings for the ECOELER YM2108.

Anpassung

The ECOELER YM2108 allows for fine-tuning of its performance to suit your specific needs. Adjustments are made using small rotary potentiometers on the switch face.

Close-up image of the ECOELER motion sensor switch showing the PIR motion detector, manual ON/OFF button, and adjustable dials for time, sensitivity, and light level.

Figure 4: Customizable settings on the ECOELER YM2108 switch.

Technische Daten

ModellnummerYM2108
BetriebsmodusEIN-AUS-EIN
Aktuelle Bewertung15 Amps
Betriebslautstärketage120 Volt (Wechselstrom)
Kompatible GeräteCFL, LED, Incandescent bulbs
Maximal Watttage300W LED, 300W CFL, 600W Incandescent
MontagetypWandhalterung
KontrollmethodeSensor (Motion Detection)
Abmessungen (L x B x H)4.72 x 2.87 x 2.24 Zoll
Betriebstemperatur32 °C bis 131 °C (0 °F bis 55 °F)
Internationale SchutzbewertungIP54
ZertifizierungenUL Certified, FCC Listed, California Title 24 Compliant

Fehlerbehebung

If issues persist after following these steps, please contact customer support or a qualified electrician.

Wartung

The ECOELER YM2108 Motion Sensor Light Switch requires minimal maintenance. Periodically, gently wipe the sensor lens with a soft, dry cloth to remove dust or debris that may obstruct its field of view. Do not use abrasive cleaners or solvents, as these can damage the device.

Garantie und Support

Dieses Produkt wird mit einem 1 Jahr eingeschränkte Garantie, covering manufacturing defects under normal use. In case of a defect, a replacement or refund may be available. For support or warranty claims, please contact the seller via Amazon.

Produktvisualisierungen

ECOELER motion sensor light switch installed in a modern bathroom setting.
The ECOELER motion sensor light switch seamlessly integrated into a modern bathroom environment, providing automated lighting.
Various indoor settings demonstrating hands-free lighting control with the ECOELER motion sensor switch.
Illustrates the convenience of hands-free lighting control in different home areas, enhancing energy savings and safety.
Image showing the ECOELER motion sensor switch in a laundry room, highlighting its PIR motion detection capability.
Passive Infrared (PIR) sensor detects motion within a 120-degree field of view, suitable for various spaces like laundry rooms, closets, and hallways.

Zugehörige Dokumente - YM2108

Vorview ECOELER YM2108T Bewegungsmelder-Lichtschalter – Installations- und Benutzerhandbuch
Ausführliche Anleitung zur Installation, Verkabelung, Justierung und Fehlerbehebung des Bewegungsmelders ECOELER YM2108T. Zu den Funktionen gehören PIR-Erkennung, Zeitverzögerung und Lux-Wert-Einstellungen.
Vorview Installationsanleitung für den Belegungs- und Leerstandssensorschalter der EverElectrix C1-Serie
Umfassende Installations- und Einstellungsanleitung für den 180°-Belegungs- und Abwesenheitssensorschalter der EverElectrix C1-Serie. Erfahren Sie, wie Sie die Verkabelung vornehmen und Zeitverzögerung, Empfindlichkeit und Betriebsmodi für die automatische Lichtsteuerung einstellen.