Pedrollo Easy Press II

PEDROLLO Presscontrol Easy Press II Elektronischer Druckregler – Benutzerhandbuch

Model: Easy Press II

Marke: Pedrollo

1. Produktüberschreitungview

The PEDROLLO Presscontrol Easy Press II is an advanced electronic device designed to automate the operation of single-phase electric pumps up to 2 HP. It manages the pump's start and stop functions based on water demand, activating the pump when a tap is opened and deactivating it when the tap is closed.

Equipped with microprocessor logic, the Easy Press II offers crucial protection features. It safeguards the pump against dry running, automatically or manually resetting the system after a dry-run event. Furthermore, it prevents excessively frequent pump starts, which can occur due to minor leaks in the water system, thereby extending the pump's lifespan and ensuring stable water pressure.

PEDROLLO Presscontrol Easy Press II Electronic Pressure Regulator

Abbildung 1: Vorderseite view of the PEDROLLO Presscontrol Easy Press II.

This image shows the compact design of the Easy Press II, featuring a pressure gauge, status indicators (Power, Out of Service, Dry, Running, Frequent Start-up), and the Pedrollo branding. The device is primarily white and blue with orange accents.

2. Hauptmerkmale

  • Automatic Pump Control: Starts and stops single-phase electric pumps based on water demand.
  • Trockenlaufschutz: Microprocessor logic prevents pump damage from operating without water, with automatic or manual reset.
  • Auslaufschutz: Protects the pump from frequent starts caused by small system leaks.
  • Integriertes Manometer: Allows for easy monitoring of system pressure.
  • Hohe Schutzklasse: IP 65 rated for dust and water resistance, suitable for various environments.
  • Robustes Design: Hergestellt aus strapazierfähigem Kunststoffmaterial.

3. Spezifikationen

AttributWert
HerstellerPEDROLLO
ModellEasy Press II
Maximaler Durchfluss200 Liters per minute (12 m³/h)
Betriebsdruck10 bar
Startdruck1.5 bar
Liquid Temperature LimitBis zu +65 °C
Ambient Temperature LimitBis zu +40 °C
Berstdruck> 40 bar
SchutzklasseSchutzart: IP 65
Bandtage230 V
Frequenz50/60 Hz
Max Current16 A (for Easy Press II)
Artikelgewicht2 Kilogramm
FarbeOrange
MaterialPlastik
StromquelleStromkabel

4. Sicherheitshinweise

Always read and understand all safety warnings and instructions before installing, operating, or maintaining the PEDROLLO Presscontrol Easy Press II. Failure to follow these instructions could result in electric shock, fire, serious injury, or property damage.

  • Ensure the power supply matches the device's specifications (230V, 50/60Hz).
  • Alle elektrischen Anschlüsse müssen von einem qualifizierten Elektriker durchgeführt werden und den örtlichen Elektrovorschriften entsprechen.
  • Vor jeglichen Installations-, Wartungs- oder Fehlersucharbeiten die Stromzufuhr unterbrechen.
  • Do not operate the device if it is damaged or if the power cable is frayed.
  • Halten Sie Kinder und unbefugtes Personal vom Installationsbereich fern.
  • Sorgen Sie für eine ordnungsgemäße Erdung, um elektrische Gefahren zu vermeiden.

5. Installation und Einrichtung

The Easy Press II is designed for easy integration into single-phase electric pump systems. Proper installation is crucial for optimal performance and safety.

  1. Montage: Install the Easy Press II vertically, ensuring the flow direction matches the arrows on the device. It should be mounted between the pump and the first point of water consumption.
  2. Hydraulischer Anschluss: Connect the inlet of the Easy Press II to the pump's discharge and the outlet to the system's piping. Ensure all connections are watertight using appropriate sealants (e.g., PTFE tape).
  3. Elektrischer Anschluss:
    • Connect the power supply cable to the Easy Press II's input terminals.
    • Connect the pump's power cable to the Easy Press II's output terminals.
    • Ensure all connections are secure and properly insulated. Refer to the wiring diagram provided in the technical documentation (Figure 2).
  4. System vorbereiten: Before starting the pump, ensure the pump and the Easy Press II are fully primed with water to prevent dry running.
  5. Erstinbetriebnahme: Once all connections are secure and the system is primed, restore power. The Easy Press II will initiate the pump when water demand is detected.
PEDROLLO Presscontrol Easy Press II Technical Diagram and Dimensions

Figure 2: Technical diagram and dimensions of the PEDROLLO Easy Press II.

This image provides detailed technical specifications, performance curves, and dimensional drawings for the Easy Press II. It illustrates various models (Easy Press 1, Easy Press 2) and their electrical characteristics, as well as typical installation setups and physical dimensions.

6. Bedienung

The PEDROLLO Easy Press II operates automatically once installed and powered. It functions as an electronic flow and pressure switch.

  • Pump Start: When a tap or valve in the system is opened, causing a drop in pressure and flow, the Easy Press II detects this demand and automatically starts the connected electric pump.
  • Pump Stop: When all taps or valves are closed, and water flow ceases, the Easy Press II detects the absence of flow and stops the pump after a short delay, maintaining system pressure.
  • Statusanzeigen: The device features LED indicators (Power, Out of Service, Dry, Running, Frequent Start-up) to provide visual feedback on its operational status. Refer to the device's front panel for specific indicator meanings.

7. Wartung

The PEDROLLO Easy Press II is designed for minimal maintenance. However, regular checks can help ensure its longevity and reliable operation.

  • Regelmäßige Inspektion: Periodically check the device and its connections for any signs of leaks, damage, or corrosion.
  • Sauberkeit: Keep the exterior of the device clean and free from dust or debris. Do not use abrasive cleaners.
  • Winterfestmachung (sofern zutreffend): In areas subject to freezing temperatures, ensure the device and connected piping are drained or protected from frost to prevent damage.
  • Pressure Gauge Check: Monitor the pressure gauge regularly to ensure it is functioning correctly and providing accurate readings.

Vor jeglichen Wartungs- oder Inspektionsarbeiten muss die Stromzufuhr zum Gerät unterbrochen werden.

8. Fehlerbehebung

The Easy Press II incorporates intelligent features to protect the pump and indicate operational issues. Here are common scenarios and their resolutions:

  • Pump Not Starting / "Dry" Indicator On:
    • Ursache: Dry running detected (no water in the pump or suction line).
    • Lösung: Ensure the pump is primed with water. The Easy Press II may attempt an automatic reset after a period. If not, manually reset the device by pressing the "START/STOP" button or by cycling the power.
  • Pump Cycling Frequently / "Frequent Start-up" Indicator On:
    • Ursache: Small leaks in the system (e.g., dripping tap, faulty toilet fill valve) or a non-return valve issue.
    • Lösung: Inspect all plumbing fixtures and connections for leaks. Repair any leaks found. Check the non-return valve in the system for proper operation.
  • Pump Not Stopping:
    • Ursache: Continuous water flow (e.g., open tap, major leak) or a sensor malfunction.
    • Lösung: Close all taps and check for significant leaks. If the pump continues to run without demand, disconnect power and contact a qualified technician.
  • No Power / "Power" Indicator Off:
    • Ursache: No electrical supply to the device.
    • Lösung: Check the circuit breaker, fuses, and power connections. Ensure the power outlet is functional.

For issues not covered here, or if troubleshooting steps do not resolve the problem, contact a qualified technician or the manufacturer's support.

9. Garantie und Support

Information regarding the specific warranty period and terms for the PEDROLLO Presscontrol Easy Press II is typically provided at the point of purchase or within separate documentation accompanying the product. Please retain your proof of purchase for warranty claims.

For technical support, spare parts, or service inquiries, please contact your authorized PEDROLLO dealer or the manufacturer directly. Information on spare parts availability was not provided in the product details.

Manufacturer: PEDROLLO

Zugehörige Dokumente - Easy Press II

Vorview Pedrollo PRESFLO MULTI Datenblatt für automatische Steuergeräte
Technisches Datenblatt für den Pedrollo PRESFLO MULTI, ein elektronisches Gerät zur Steuerung und zum Schutz von einphasigen Hauswasserpumpen. Detaillierte Informationen zu Funktionen, Spezifikationen, Installation und Einstellung für Wasserversorgungs- und Bewässerungssysteme.
Vorview Pedrollo EP Electronic Pump Protector: Installation and Operation Guide
Comprehensive guide to the Pedrollo EP electronic pump protector, detailing its functions for dry running, overcurrent, and voltage protection, along with installation and operation instructions.
Vorview Automatisches Steuergerät Pedrollo PRESFLO MULTI - Technische Daten
Detaillierte technische Daten, Installationsanleitung und Funktionen des automatischen elektronischen Druckregelgeräts Pedrollo PRESFLO MULTI für die häusliche Wasserversorgung und Druckerhöhung.
Vorview Pedrollo EP Elektronisches Schutzgerät – Benutzerhandbuch & Datenblatt
Ausführlicher Leitfaden zum elektronischen Schutzgerät Pedrollo EP mit detaillierten Informationen zu Funktionen, technischen Daten, Installation und Bedienung. Schützt Pumpen vor Trockenlauf, Überstrom und Überdruck.tage, und Untervoltage. Geeignet für den Hausgebrauch.
Vorview EVOLUTION Elektronisches Bedienfeld für elektrische Pumpen - PEDROLLO Benutzerhandbuch
Ausführliches Benutzerhandbuch für das elektronische Bedienfeld PEDROLLO EVOLUTION mit detaillierten Informationen zu Installation, Betrieb, Programmierung, technischen Spezifikationen und Fehlerbehebung für einphasige und dreiphasige elektrische Pumpen.
Vorview Pedrollo E1-E2 Electronic Electrical Panels for Pumps
Comprehensive guide to Pedrollo E1 and E2 electronic control panels, designed for managing single or dual pump systems in residential, commercial, and industrial settings. Features include selectable operating modes, dry-running protection, and intuitive user interfaces for efficient pump operation.