DENALI DNL.WHS.11602

DENALI CANsmart Controller GEN II for BMW R1200LC & R1250 Series Motorcycles User Manual

Model: DNL.WHS.11602

Einführung

The DENALI CANsmart Controller GEN II is an advanced accessory management system designed specifically for BMW R1200LC and R1250 series motorcycles. This device provides plug-and-play installation and intelligent control of up to four DENALI accessories, such as auxiliary lights, horns, and brake lights, directly through the motorcycle's CAN bus system. It simplifies wiring and offers customizable settings for various functions, enhancing both safety and convenience.

Packungsinhalt

Bitte überprüfen Sie, ob alle unten aufgeführten Artikel in Ihrem Paket enthalten sind:

DENALI CANsmart Controller GEN II package contents

Bild: Contents of the DENALI CANsmart Controller GEN II package, including the main controller unit, various wiring harnesses, battery connectors, USB cable, zip ties, and an adhesive pad.

Sicherheitshinweise

Before installation and operation, please read and understand all safety warnings and instructions. Failure to do so may result in property damage, injury, or death.

Setup und Installation

Follow these steps for proper installation of your DENALI CANsmart Controller GEN II.

Schritt 1: Bereiten Sie das Motorrad vor

  1. Stellen Sie das Motorrad auf einer ebenen Fläche ab und vergewissern Sie sich, dass es stabil steht.
  2. Zündung ausschalten und Schlüssel abziehen.
  3. Disconnect the negative terminal of the motorcycle's battery.
  4. Remove any necessary body panels or seats to access the CAN bus connector and battery.

Step 2: Connect the CANsmart Controller

  1. Locate the motorcycle's CAN bus connector. Refer to your motorcycle's service manual for its exact location (often under the seat or near the diagnostic port).
  2. Connect the CAN bus connector cable from the CANsmart Controller to the motorcycle's CAN bus port. This is a plug-and-play connection.
  3. Connect the battery terminal wires from the CANsmart Controller to the motorcycle's battery terminals. Ensure the red wire connects to the positive (+) terminal and the black wire connects to the negative (-) terminal. The main fuse is integrated into the positive wire.
DENALI CANsmart Controller installed on a BMW motorcycle

Bild: The DENALI CANsmart Controller GEN II unit installed discreetly under the seat of a BMW motorcycle, showing its compact size and integration with existing wiring.

Schritt 3: Zubehör anschließen

  1. Identify which of the four accessory circuits (Red, Blue, Yellow, White) you will use for each accessory. Each circuit has a 10A continuous rating.
  2. Connect your DENALI accessories (e.g., auxiliary lights, horn, brake light) to the corresponding CANsmart circuit harnesses. Ensure proper polarity.
  3. Route all wiring neatly and securely using the provided zip ties, keeping them away from heat sources and moving parts.
DENALI CANsmart Controller wiring diagram

Bild: A detailed wiring diagram illustrating the connections for the DENALI CANsmart Controller. It shows the main unit, CAN bus connector, battery terminals with a 30A fuse, and the four accessory circuits (White, Yellow, Blue, Red), each rated for 10A.

Step 4: Secure the Controller

Use the adhesive mounting pad to secure the CANsmart Controller unit in a safe, dry location, typically under the seat or within a fairing, ensuring it is not exposed to direct elements or excessive heat.

Step 5: Reconnect Battery and Test

  1. Schließen Sie den Minuspol der Motorradbatterie wieder an.
  2. Turn on the ignition and perform initial tests of your connected accessories.

Software Configuration and Operating Instructions

The CANsmart Controller's full functionality is accessed and customized via the DENALI CANsmart software, available for download from the DENALI website. This software allows you to assign specific functions to each of the four circuits and adjust their behavior.

Herstellen einer Verbindung zur Software

  1. Download and install the DENALI CANsmart software on your computer.
  2. Connect the CANsmart Controller to your computer using the provided USB programming cable.
  3. Launch the CANsmart software. The software should automatically detect the connected controller.

Circuit Functions

The software interface allows you to configure each circuit independently. Common functions include:

DENALI CANsmart software interface for circuit functions

Bild: Screenshot of the DENALI CANsmart software interface, showing options to configure the Red, Blue, Yellow, and White circuits. Icons represent various functions like Light Pair 1, Horn, Brake Light, and Accessory, with options to apply or cancel changes.

Anpassen der Einstellungen

Within the software, you can adjust parameters such as:

Refer to the software's built-in help or the DENALI website for detailed instructions on each function and setting.

Wartung

The DENALI CANsmart Controller GEN II is designed for maintenance-free operation. Periodically inspect the wiring and connections for any signs of wear, corrosion, or damage. Ensure the controller unit remains securely mounted and free from excessive moisture or heat.

Fehlerbehebung

If you encounter issues with your CANsmart Controller, refer to the following common problems and solutions:

ProblemMögliche UrsacheLösung
Accessories not turning on.
  • Wackelkontakt.
  • Durchgebrannte Sicherung.
  • Incorrect software configuration.
  • Accessory malfunction.
  • Check all wiring connections to the CANsmart and accessories.
  • Inspect the main 30A fuse and individual accessory fuses (if applicable).
  • Verify circuit functions and settings in the CANsmart software.
  • Test the accessory directly to a 12V source to confirm functionality.
CANsmart not detected by software.
  • Problem mit dem USB-Kabel.
  • Software driver issue.
  • Controller not powered.
  • Versuchen Sie es mit einem anderen USB-Anschluss oder Kabel.
  • Ensure CANsmart software drivers are correctly installed.
  • Verify the CANsmart Controller is connected to the motorcycle battery and the motorcycle ignition is on.
Intermittent accessory operation.
  • Wackelkontakt.
  • Überstromschutz.
  • Überprüfen Sie alle Kabelverbindungen auf festen Sitz.
  • Ensure the accessory's current draw does not exceed the 10A circuit limit.

If the problem persists, contact DENALI customer support for further assistance.

Technische Daten

Garantieinformationen

DENALI products are covered by a limited warranty against defects in materials and workmanship. The specific warranty period and terms may vary. Please retain your proof of purchase. For detailed warranty information, please visit the official DENALI webWebsite oder wenden Sie sich an den Kundendienst.

Unterstützung

For technical assistance, troubleshooting, or further inquiries regarding your DENALI CANsmart Controller GEN II, please visit the DENALI Electronics webWebsite oder wenden Sie sich an das Kundensupport-Team.

WebWebsite: www.denalielectronics.com

Weitere Informationen finden Sie im webWebsite mit den aktuellsten Kontaktinformationen und Support-Ressourcen.

Zugehörige Dokumente - DNL.WHS.11602

Vorview DENALI GEN II CANsmart Controller für BMW R1200/R1250 Serie: Installations- und Benutzerhandbuch
Ausführliche Anleitung zur Installation und Bedienung des DENALI GEN II CANsmart Controllers an Motorrädern der BMW R1200 LC und R1250 Baureihe. Mit Plug-and-Play-Zubehörsteuerung, individuell anpassbaren Einstellungen und intelligenter Bremslichtfunktion.
Vorview DENALI GEN II CANsmart Controller für Yamaha Tenere 700 Installationshandbuch
Ausführliche Installations- und Bedienungsanleitung für den DENALI GEN II CANsmart Controller, entwickelt für Yamaha Tenere 700 Modelle. Beinhaltet den Lieferumfang, die Verkabelung, die Softwareeinrichtung und die Integration ins Motorrad.
Vorview DENALI CANsmart Controller Installation and Operation Manual
Comprehensive guide for installing and operating the DENALI CANsmart Controller, including wiring, software setup, and troubleshooting for motorcycle accessories.
Vorview DENALI CANsmart Wiring Harness for T3 Switchback Signals Installation Manual
Installation instructions and configuration guide for the DENALI CANsmart Wiring Harness, designed for T3 Switchback Signals. Includes wiring diagrams, software setup, and troubleshooting tips.
Vorview DENALI DialDim™ Lichtsteuerung BMW R1250GS Installationsanleitung
Ausführliche Bedienungsanleitung für den DENALI DialDim™ Lichtregler (Modell DNL.WHS.25600) für die BMW R1250GS. Beinhaltet Installation, Funktionen, Bedienelemente und Fehlerbehebung.
Vorview DENALI D7 LED-Lichtpod-Installationsanleitung
Offizielle Bedienungsanleitung für den DENALI D7 LED-Leuchten-Pod (DNL.D7.050). Enthält Installationstipps, Drehmomentangaben, Montageorte und Ausrichtungsverfahren für Motorräder.