1. Einleitung

Thank you for choosing the PowerWalker VI 3000 SCL FR Uninterruptible Power Supply (UPS). This device is designed to provide reliable power protection for your electronic equipment against power outages, surges, and spikes. It ensures continuous operation and safeguards your valuable data and hardware.

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your UPS. Please read it thoroughly before using the product and keep it for future reference.

PowerWalker VI 3000 SCL FR UPS, angled front view

Figure 1.1: PowerWalker VI 3000 SCL FR UPS

This image shows the PowerWalker VI 3000 SCL FR UPS from an angled front perspective, highlighting its compact black casing and the front display panel.

2. Sicherheitshinweise

Please observe the following safety precautions to ensure safe operation and to prevent damage to the UPS or connected equipment.

  • Elektrische Sicherheit: Öffnen Sie das UPS-Gehäuse nicht.asing. There are no user-serviceable parts inside. Refer all servicing to qualified service personnel. Ensure the UPS is connected to a grounded power outlet.
  • Platzierung: Place the UPS in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Do not block ventilation openings.
  • Batteriesicherheit: The UPS contains internal batteries. Do not dispose of batteries in a fire, as they may explode. Do not open or mutilate batteries. Electrolyte is harmful to the skin and eyes.
  • Überlast: Do not overload the UPS. Ensure the total power consumption of connected devices does not exceed the UPS's rated capacity (1800W).

3. Packungsinhalt

Carefully unpack the UPS and check the contents of the package. You should find the following items:

  • PowerWalker VI 3000 SCL FR UPS Unit
  • Benutzerhandbuch (dieses Dokument)
  • USB Cable (for HID driver communication)
  • Stromkabel)

Sollten Teile fehlen oder beschädigt sein, wenden Sie sich bitte umgehend an Ihren Händler.

4. Produktüberschreitungview

4.1 Frontplatte

PowerWalker VI 3000 SCL FR UPS front panel

Figure 4.1: Front Panel of the UPS

This image displays the front panel of the PowerWalker VI 3000 SCL FR UPS, showing the LCD display and the power button.

  1. LCD Anzeige: Zeigt Statusinformationen in Echtzeit an, wie z. B. Eingangs-/Ausgangslautstärke.tage, Batteriestand, Ladekapazität und verschiedene Betriebsmodi.
  2. Netzschalter: Used to turn the UPS ON or OFF.

4.2 Rückseite

PowerWalker VI 3000 SCL FR UPS rear panel with ports

Figure 4.2: Rear Panel of the UPS

This image illustrates the rear panel of the PowerWalker VI 3000 SCL FR UPS, detailing the various input/output ports and sockets.

  1. COM.PORT (RS-232): Serial communication port for monitoring software.
  2. USB-Anschluss: USB communication port for monitoring software and HID driver functionality.
  3. Output Sockets (French Type): Connect your critical equipment here. These outlets provide battery backup and surge protection.
  4. Eingangsnetzkabel: Verbindet die USV mit der Steckdose.
  5. RJ11/RJ45 Protection (IN/OUT): Provides surge protection for telephone/network lines.
  6. Reset-Taste: Used to reset the UPS in certain error conditions.

5. Einrichtung

5.1 Platzierung

Choose a suitable location for your UPS:

  • Stellen Sie die USV auf eine ebene, stabile Oberfläche.
  • Ensure adequate airflow around the unit. Maintain at least 10 cm (4 inches) clearance from walls or other obstructions.
  • Avoid areas with excessive dust, humidity, or extreme temperatures.

5.2 An die Stromversorgung anschließen

  1. Connect the UPS input power cord to a grounded wall outlet.
  2. Allow the UPS to charge for at least 8 hours before initial use to ensure optimal battery runtime. The UPS will charge whether it is turned ON or OFF.

5.3 Anschließen von Geräten

  1. Plug your computer, monitor, and other critical devices into the output sockets on the rear panel of the UPS.
  2. Do not connect laser printers or shredders to the UPS, as their high surge current during startup may overload the unit.
  3. For network/telephone line protection, connect your modem/router to the RJ11/RJ45 IN port and then connect the OUT port to your device.

6. Betrieb

6.1 Turning the UPS ON/OFF

  • Zum Einschalten: Halten Sie den Netzschalter auf der Vorderseite etwa 3 Sekunden lang gedrückt, bis Sie einen Piepton hören und das LCD-Display aufleuchtet.
  • Ausschalten: Press and hold the power button for approximately 3 seconds until you hear a beep and the LCD display turns off.

6.2 Das LCD-Display verstehen

The LCD display provides real-time status of the UPS. Key indicators include:

  • Eingangslautstärketage: Zeigt die aktuelle Netzstromstärke antage.
  • Ausgangsvolumentage: Zeigt die Lautstärke antagDie von der USV bereitgestellten e werden an die angeschlossenen Geräte geliefert.
  • Batteriestand: Zeigt den verbleibenden Ladezustand des Akkus an.
  • Tragfähigkeit: Zeigt den Prozentsatztage der von den angeschlossenen Geräten genutzten Kapazität der USV.
  • Betriebsart: Indicates if the UPS is operating on utility power (AC mode) or battery power (Battery mode).

6.3 Softwareinstallation (optional)

For advanced monitoring and management features, you can install the PowerWalker monitoring software. This software allows you to:

  • Überwachen Sie den Status der USV und die Stromversorgungsbedingungen.
  • Perform scheduled shutdowns.
  • Receive alerts for power events.

Connect the UPS to your computer using the provided USB cable. The UPS supports HID (Human Interface Device) driver, allowing basic functionality without additional software on compatible operating systems.

7. Wartung

7.1 Batteriepflege

  • To maintain optimal battery life, ensure the UPS is connected to a power outlet at all times to keep the batteries charged.
  • Perform a battery calibration (if supported by software) or a full discharge/recharge cycle every 3-6 months to ensure accurate battery runtime readings.
  • Batteries are consumable items and will degrade over time. Replace batteries when their runtime significantly decreases.

7.2 Reinigung

Reinigen Sie die Außenseite der USV mit einem weichen, trockenen Tuch. Verwenden Sie keine flüssigen oder Aerosol-Reinigungsmittel. Stellen Sie sicher, dass die Lüftungsöffnungen frei von Staub und Schmutz sind.

7.3 Speicherung

If storing the UPS for an extended period, ensure the batteries are fully charged. Recharge the batteries every three months to prevent permanent damage due to self-discharge.

8. Fehlerbehebung

If you encounter issues with your UPS, refer to the following table for common problems and solutions:

ProblemMögliche UrsacheLösung
UPS does not turn ONNo utility power; Low battery; Power button not pressed long enough.Check power cord connection; Allow UPS to charge for 8 hours; Press and hold power button for 3 seconds.
Die USV piept im Netzbetrieb ununterbrochen.Überlastungszustand.Disconnect non-essential equipment until the alarm stops.
UPS switches to battery mode frequentlyUnstable utility power; High/low input voltage.This is normal operation. If frequent, check utility power quality.
Die Akkulaufzeit ist kürzer als erwartet.Batteries not fully charged; Batteries reaching end of life; Overload.Allow 8 hours for charging; Consider battery replacement; Reduce connected load.

Sollte das Problem nach Anwendung der oben genannten Lösungsansätze weiterhin bestehen, wenden Sie sich bitte an den Kundendienst.

9. Spezifikationen

Technical specifications for the PowerWalker VI 3000 SCL FR UPS:

BesonderheitWert
Modellnummer10121151
Kapazität3000 VA / 1800 W.
Bandtage290 Volt
Technische Daten39.7 x 14.6 x 20.5 cm
Artikelgewicht11.5 Kilogramm
FarbeSchwarz
MaterialPolycarbonat (PC)
Erstes verfügbares Datum27. Dezember 2019

10. Garantie und Support

10.1 Garantieinformationen

PowerWalker products are manufactured to the highest quality standards. This UPS comes with a standard manufacturer's warranty against defects in materials and workmanship. Please refer to the warranty card included with your product or visit the official PowerWalker webAuf der Webseite finden Sie die detaillierten Garantiebedingungen.

10.2 Kundendienst

For technical assistance, troubleshooting, or warranty claims, please contact PowerWalker customer support. You can typically find contact information on the PowerWalker official webWebsite oder über Ihren lokalen Händler.

Bitte halten Sie bei Kontaktaufnahme mit dem Support Ihre Produktmodellnummer (10121151) und die Seriennummer bereit.

Zugehörige Dokumente - 10121151

Vorview PowerWalker Basic VI 3000 STL Benutzerhandbuch und technische Daten
Benutzerhandbuch für die Line-Interactive-USV PowerWalker Basic VI 3000 STL mit detaillierten Informationen zu Installation, Betrieb, technischen Daten, Fehlerbehebung und Softwareverwaltung für zuverlässigen Stromschutz.
Vorview PowerWalker 1000VA/1500VA Line Interactive Sinuswellen-USV – Benutzerhandbuch
Dieses Benutzerhandbuch enthält detaillierte Informationen zu den PowerWalker 1000VA und 1500VA Line Interactive Sinewave USV-Modellen, einschließlich Sicherheitshinweisen, Installation, Bedienung, Batteriewechsel, Fehlerbehebung und technischen Spezifikationen.
Vorview PowerWalker Inverter 3000 PSW Benutzerhandbuch
Benutzerhandbuch für den PowerWalker Inverter 3000 PSW mit detaillierten Informationen zu Installation, Betrieb, Spezifikationen und Fehlerbehebungsverfahren für eine zuverlässige Stromumwandlung.
Vorview PowerWalker VFI USV-Benutzerhandbuch: Installation, Betrieb und Wartung
Ausführliches Benutzerhandbuch für die unterbrechungsfreien Stromversorgungen (USV) der Serien PowerWalker VFI 1000, 1500, 2000 und 3000 TG/TGS/TGB. Beinhaltet Informationen zu Sicherheit, Installation, Betrieb, Fehlerbehebung, technischen Daten und Software.
Vorview PowerWalker VI (E)RT HID Series Quick Guide
This quick guide provides essential information for assembling, operating, and configuring the PowerWalker VI (E)RT HID Series Uninterruptible Power Supply (UPS) units, including rear panel descriptions, communication port details, initial startup procedures, user settings, operating modes, and technical specifications.
Vorview PowerWalker VI 650-3000 LCD Kurzanleitung
Dieses Dokument bietet eine Kurzanleitung zu den unterbrechungsfreien Stromversorgungen (USV) der PowerWalker VI 650-3000 LCD-Serie und beschreibt detailliert die Komponenten auf der Vorder- und Rückseite, Alarmfunktionen und technischen Daten.