AMTAST AMT212

AMTAST AMT212 Portable Leeb Hardness Tester Instruction Manual

Modell: AMT212

1. Einleitung

The AMTAST AMT212 is a portable digital Leeb hardness tester designed for accurate hardness measurements of large, hard metallic materials. It features a built-in printer for immediate result output, a true color TFT display, and supports multiple hardness scales. This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your AMT212 device.

2. Sicherheitshinweise

Please read and understand all safety instructions before operating the AMT212 hardness tester. Failure to follow these instructions may result in injury or damage to the device.

3. Packungsinhalt

Überprüfen Sie, ob alle Artikel im Paket vorhanden sind:

4. Produktüberschreitungview

The AMT212 features an intuitive interface and robust design for reliable hardness testing.

AMTAST AMT212 Portable Leeb Hardness Tester with built-in printer and display

Abbildung 4.1: Vorderseite view of the AMTAST AMT212 Portable Leeb Hardness Tester, showing the display, control buttons, and built-in printer.

Hauptmerkmale:

Diagram illustrating key features of the AMT212: Built-in Printer, Automatic Alarm, Hardness Scale Dual-display, and Battery Information Indication.

Figure 4.2: Visual representation of the AMT212's core functionalities, including the built-in printer, automatic alarm, dual hardness scale display, and battery indicator. The image also illustrates the device's versatility for use at various angles and in narrow spaces, and shows the standard D impact device.

Seite view of the AMTAST AMT212 Hardness Tester showing the kickstand, USB port, and power switch.

Abbildung 4.3: Seite view of the AMT212, highlighting the integrated kickstand for angled viewing, the USB port for data transfer or charging, and the power ON/OFF switch.

Hinteren view of the AMTAST AMT212 Hardness Tester with the standard D impact device connected.

Abbildung 4.4: Rückseite view of the AMT212, showing the connection point for the standard D impact device and product labeling with model number, battery type, charger specifications, and printer paper width.

5. Einrichtung

5.1 Laden des Akkus

Before first use, ensure the device is fully charged. Connect the charger to the device's charging port and plug it into a power outlet. The battery status indicator on the display will show the charging progress.

5.2 Anschließen des Aufprallgeräts

Carefully connect the standard D impact device cable to the designated port on the AMT212. Ensure a secure connection. The device will automatically identify the connected impact device type.

5.3 Druckerpapier einlegen

Open the printer cover located at the top of the device. Insert a roll of 58mm thermal paper, ensuring the paper feeds correctly through the mechanism. Close the cover securely.

6. Bedienungsanleitung

6.1 Ein-/Ausschalten

Zum Ein- oder Ausschalten des Geräts den Netzschalter (normalerweise mit einem Netzschaltersymbol gekennzeichnet) gedrückt halten.

6.2 Menünavigation

The AMT212 features a menu-driven interface. Use the arrow keys (Up, Down, Left, Right) and the 'MENU' or 'OK' button to navigate through options and confirm selections. The true color TFT screen provides rich and intuitive information.

6.3 Selecting Material and Hardness Scale

From the main menu, select the appropriate material type (e.g., Steel, Cast Iron, Aluminum Alloy) and the desired hardness scale (e.g., HL, HRC, HB). The device allows for arbitrary switching between materials and hardness scales.

6.4 Durchführung einer Messung

  1. Ensure the surface of the test piece is clean, smooth, and free from scale, oil, or other contaminants.
  2. Platzieren Sie das Aufprallgerät fest und senkrecht auf der Testfläche.
  3. Press the release button on the impact device to initiate the impact. The measurement will be displayed on the screen.
  4. Repeat the measurement multiple times (typically 3-5 times) at different points on the test piece to ensure accuracy and consistency.
  5. The device can be used at any angle, including upside down, in narrow spaces, or other challenging working conditions.

6.5 Saving and Printing Results

Use the 'SAVE' button to store measurement data in the device's memory. The 'PRINT' button will immediately print the current test results via the built-in printer. The 'FEED' button advances the paper.

6.6 Automatic Alarm Function

The device features an automatic alarm function suitable for batch testing. If a test result falls outside pre-set tolerance limits, the device will automatically alert the user.

6.7 Kalibrierungsfunktionen

The AMT212 includes a starting value calibration function to ensure data applicability and accuracy across different codes and standards, as well as a user calibration function for fine-tuning.

7. Hardness Scales and Applicable Materials

Hardness scales and measuring ranges for the AMT212 Leeb Hardness Tester, including HL, HB, HRB, HRC, HRA, HV, HS.

Figure 7.1: Display showing the available hardness scales (HL, HB, HRB, HRC, HRA, HV, HS) and their respective measuring ranges. The image also illustrates a typical measurement display with MAX and MIN values.

7.1 Measuring Range:

The device can also switch to Strength (σb) mode.

7.2 Applicable Materials:

The AMT212 is suitable for testing a wide range of metallic materials:

Illustrations of material types applicable for testing with the AMT212: Steel, Iron, Alloy, and Copper (Bronze).

Figure 7.2: Graphical representation of the various material categories that can be tested using the AMT212, including different types of steel, cast iron, various alloys, and copper-based materials.

8. Wartung

8.1 Gerät reinigen

Regularly wipe the exterior of the device with a soft, dry cloth. Do not use liquid cleaners or solvents, as they may damage the display or internal components.

8.2 Cleaning the Impact Device

Use the provided cleaning brush to remove any debris from the impact device, especially the impact body and guide tube. Ensure the impact body moves freely. Do not lubricate the impact device.

8.3 Speicherung

When not in use, store the AMT212 and its accessories in the provided carrying case in a dry, dust-free environment, away from direct sunlight and extreme temperatures.

8.4 Batteriepflege

To prolong battery life, avoid fully discharging the battery frequently. If storing the device for an extended period, charge the battery to approximately 50% and recharge every few months.

9. Fehlerbehebung

Problem Mögliche Ursache Lösung
Gerät lässt sich nicht einschalten. Niedriger oder leerer Akku. Laden Sie den Akku mit dem mitgelieferten Ladegerät auf.
Ungenaue Messwerte.
  • Impact device not properly connected.
  • Test surface not clean or smooth.
  • Incorrect material or hardness scale selected.
  • Impact device requires cleaning or replacement.
  • Ensure impact device is securely connected.
  • Clean and prepare the test surface.
  • Verify selected material and scale.
  • Clean the impact device or consider replacement if worn.
Drucker druckt nicht.
  • No paper or paper jammed.
  • Printer cover not closed properly.
  • Check and load new thermal paper.
  • Ensure printer cover is fully closed.
Display issues (e.g., frozen screen). Softwarefehler oder vorübergehender Irrtum. Turn off the device, wait a few seconds, then turn it back on. If the problem persists, contact customer support.

10. Spezifikationen

Specifications of the AMTAST AMT212 Precision Hardness Tester, including display type, indication error, measuring direction, memory, working temperature, size, weight, and power source.

Figure 10.1: Detailed specifications of the AMT212, highlighting its precision and technical capabilities.

Parameter Wert
Messbereich HLD:170~960, HRC:17.9~69.5, HB:19~683, HV:80~1042, HS:30.6~102.6, HRA:59.1~88, HRB:13.5~101.7
Measuring Materials Steel and cast steel, alloy tool steel, stainless steel, gray cast iron, nodular cast iron, cast aluminum alloy, copper zinc alloys (brass), copper and tin alloy, copper(bronze), forged steel
Härteskalen HL, HB, HRB, HRC, HRA, HV, HS (can switch to Strength σb mode)
Messrichtung 360°
Anzeigefehler ±6HLD (D impact device)
Anzeige 320x240 true color TFT screen
Leistung Wiederaufladbarer Li-Akku
Arbeitstemperatur -20°C bis 55°C
Größe 210x85x45mm
Gewicht 0.6 kg
Erinnerung Max 600 groups (relative to impact times 1~32 adjustable)

11. Garantieinformationen

AMTAST products are manufactured to high quality standards. This product is covered by a limited warranty against defects in materials and workmanship for a period of one (1) year from the original date of purchase. This warranty does not cover damage caused by misuse, accident, unauthorized modification, or normal wear and tear. Please retain your proof of purchase for warranty claims.

12. Kundendienst

For technical assistance, troubleshooting, or warranty inquiries, please contact AMTAST customer support. Refer to the contact information provided with your product packaging or visit the official AMTAST webBesuchen Sie die Website für die aktuellsten Supportinformationen.

When contacting support, please have your product model number (AMT212) and purchase date available.

Zugehörige Dokumente - AMT212

Vorview AMTAST Oberflächenrauheitsmessgerät – Bedienungsanleitung
Ausführliche Bedienungsanleitung für das AMTAST Oberflächenrauheitsmessgerät mit detaillierten Informationen zu Funktionen, Bedienung, Wartung, Fehlerbehebung und technischen Spezifikationen für eine präzise Oberflächentexturanalyse.
Vorview AMTAST Bewässerungsuhr: Installations-, Bedienungs- und Fehlerbehebungsleitfaden
Ausführlicher Leitfaden für den AMTAST-Wasserzeitschalter, der das Produkt überviewSpezifikationen, Installation, Einstellungen für das automatische Bewässerungsprogramm, manuelle Bewässerung, Regenverzögerung, Kindersicherung und häufig gestellte Fragen.
Vorview AMT-105 Innen-/Außen-Alarmthermometer – Produktanleitung
Produkthandbuch für das AMTAST AMT-105 Innen-/Außen-Alarmthermometer mit detaillierter Beschreibung der Funktionen, Spezifikationen, Installationsschritte und Bedienungshinweise.
Vorview Amtast AMT620 Labor-pH-Meter – Merkmale und Spezifikationen
Detaillierte Informationen zum Amtast AMT620 Labor-pH-Meter, einschließlich seiner Funktionen wie automatischer/manueller pH-Temperaturkompensation, GLP-Funktion, Datenspeicherung und RS232-Schnittstelle. Spezifikationen für pH-, mV- und Temperaturmessbereiche sowie Genauigkeit werden bereitgestellt.