1. Einleitung

This manual provides essential information for the installation, operation, and maintenance of the FERMAX 4825 DUOX Plus DIN10 24VDC 2.5A Power Supply with Filter. This unit is designed to provide stable and reliable power to various FERMAX DUOX Plus intercom system components.

The FERMAX 4825 is a DIN rail mountable power supply, featuring a 24V DC output at 2.5A, and an integrated filter for optimal performance within DUOX Plus systems. It is protected by an electronic fuse to ensure safety and longevity.

2. Produktüberschreitungview

FERMAX 4825 DUOX Plus DIN10 Power Supply with labels for input, output, power bus, and indicators.

Abbildung 1: Front view of the FERMAX 4825 DUOX Plus DIN10 Power Supply. The image displays the input terminals (N, L), output terminals (24V, 2.5A), Power Bus and Prev Bus terminals, and LED indicators for ON and OVERLOAD status. Key specifications like input voltage (100-240V; 1.2A, 50-60Hz) and output voltage (24V; 2.5A) are visible, along with the FERMAX brand logo and model number REF. 4825.

The FERMAX 4825 power supply is equipped with the following key features:

3. Sicherheitshinweise

4. Einrichtung und Installation

4.1 Montage

  1. Select a suitable location within an electrical cabinet or distribution board that allows for proper ventilation.
  2. Mount the FERMAX 4825 power supply onto a standard DIN rail. Ensure it is securely fastened.

4.2 Kabelverbindungen

Die Positionen der Anschlüsse entnehmen Sie Abbildung 1.

  1. Eingangsleistung (AC): Connect the main AC power supply to the terminals labeled N (Neutral) and L (Line). Ensure proper polarity. The input range is 100-240V AC, 50-60 Hz.
  2. Masseanschluss: Connect the protective earth ground to the terminal marked with the ground symbol.
  3. Output Power (DC): Connect the DUOX Plus equipment requiring 24V DC power to the terminals labeled + Und - under "OUTPUT". The output is 24V DC, 2.5A.
  4. Power Bus / Prev Bus: Connect the DUOX Plus system bus lines to the "POWER BUS" and "PREV BUS" terminals as per your specific DUOX Plus system diagram. These terminals are typically used for data and power distribution within the intercom system.

Important: Double-check all wiring connections before applying power to prevent damage to the unit or connected equipment.

5. Bedienungsanleitung

5.1 Einschalten

  1. After ensuring all connections are secure and correct, switch on the main AC power supply to the unit.
  2. The "ON" LED indicator on the front panel should illuminate, indicating that the power supply is active and providing output voltage.

5.2 Statusanzeigen

6. Wartung

The FERMAX 4825 power supply is designed for reliable, long-term operation with minimal maintenance. Follow these guidelines:

7. Fehlerbehebung

8. Spezifikationen

BesonderheitSpezifikation
MarkeFERMAX
Modell4825 (F04825)
Eingangslautstärketage100-240V AC
Eingangsfrequenz50-60 Hz
Eingangsstrom1.2 A
Ausgangsvolumentage24 V Gleichstrom
Ausgangsstrom2.5 A
Leistungsabgabe60 Watt
KühlmethodeAir Cooling / Ventilator
MontageDIN Rail (DIN10)
SchutzElectronic Fuse Protected
Gewicht96 Gramm

Hinweis: Technische Daten können ohne vorherige Ankündigung geändert werden.

9. Garantie und Support

FERMAX products are manufactured to high-quality standards. This product includes a satisfaction guarantee and quality customer service.

For technical support, warranty claims, or further assistance, please contact your local FERMAX distributor or visit the official FERMAX website. Please have your product model (4825) and serial number (if applicable) ready when contacting support.

Weitere Informationen finden Sie unter FERMAX official webWebsite.

Zugehörige Dokumente - 4825

Vorview Fermax DUOX Plus Power Supply Ref. 4826: Technical Specifications and Installation Guide
Comprehensive technical specifications, safety guidelines, and installation instructions for the Fermax DUOX Plus Power Supply (Ref. 4826), a 24Vdc 1.5A unit designed for professional audio-visual and intercom systems.
Vorview Fermax VEO DUOX Plus Monitor – Kurzanleitung für den Benutzer
Eine Kurzanleitung zur Bedienung des Fermax VEO DUOX Plus-Video-Gegensprechanlagenmonitors mit detaillierten Informationen zu Steuertasten, Benutzermenünavigation, Parametereinstellungen, Melodieauswahl, Bilderfassung und Türmatikfunktionen.
Vorview [DUOX PLUS] Ersatzteil PVT09375 Mikrofon Amplifier MARINE Ersatzhandbuch
Schritt-für-Schritt-Anleitung zum Austausch des PVT09375-Mikrofons amplifier auf einem FERMAX DUOX PLUS MARINE-System. Enthält detaillierte Anleitungen und Bilder.
Vorview Integrationshandleiding: Fermax Meet Intercom met xxter
Erfahren Sie, wie Sie Ihr Fermax Meet-Intercom-System in die xxter-Plattform integrieren, um die erweiterte Video-Intercom-Funktionalität zu verbessern. Diese Anleitung enthält ausführliche Anleitungen zur Konfiguration und Installation.
Vorview Fermax DSV-01/XS 1/W Veo Wifi Duox Plus Cityline Video-Gegensprechanlage
Eine umfassende Anleitung zum Video-Türsprechsystem Fermax 94411 mit Duox Plus-Technologie für vereinfachte Installation und robuste Leistung. Dieses Kit enthält ein Cityline-Außenpanel und einen Veo Wi-Fi-Freisprechmonitor mit Fernzugriff über die Fermax Blue-App.
Vorview Fermax Meet Video-Türsprechanlage – Konfigurationsleitfaden mit Zennio-Inneneinheiten
Ein umfassender Konfigurationsleitfaden zur Integration von Fermax Meet Video-Türsprechanlagen mit Zennio-Inneneinheiten (Z50, Z70 v2, Z100). Beinhaltet die Netzwerkeinrichtung, SIP-Anrufe und die Konfiguration der Außeneinheit für Installationen in Privathaushalten.