Mastervolt 45513000

MASTERVOLT Alpha Pro III

Bedienungsanleitung

Einführung

The Mastervolt Alpha Pro III is an advanced charge regulator designed to optimize the charging process of your batteries. This device ensures efficient and safe power management for various applications, particularly in marine and mobile environments. It is engineered for reliability and ease of integration into existing power systems.

Key features include intelligent multi-stage charging, temperature compensation, and compatibility with 12V-24V systems. This manual provides detailed instructions for installation, operation, maintenance, and troubleshooting to ensure optimal performance and longevity of your Alpha Pro III.

Produkt überview

Mastervolt Alpha Pro III device with various ports and labels

Figure 1: Mastervolt Alpha Pro III device. This image displays the compact, dark grey unit. Visible connections include a "TEMP SENSE" port (RJ45-like), a 4-pin connector, three spade terminals labeled "+BAT", "FIELD", and "GND", and two additional RJ45-like ports. The top surface features the "MASTERVOLT ALPHA PRO III" branding, a label indicating "Type: Alpha Pro III", "Input: 12V-24V-MB", and a serial number. Three small indicator lights are also visible on the top surface.

The Alpha Pro III unit is designed for robust performance. It features clearly labeled connection points for easy installation. The input voltage range is 12V to 24V, making it versatile for different battery bank configurations. Indicator lights provide quick status feedback during operation.

Setup und Installation

Proper installation is crucial for the safe and efficient operation of the Alpha Pro III. Always ensure the power supply is disconnected before making any connections.

  1. Montage: Select a dry, well-ventilated location away from direct heat sources and flammable materials. Secure the unit using appropriate fasteners through the mounting holes.
  2. Anschluss Temperatursensor: Connect the temperature sensor cable to the port labeled "TEMP SENSE". This sensor is vital for accurate temperature-compensated charging.
  3. Battery Connection (+BAT): Connect the positive battery cable to the terminal labeled "+BAT". Ensure a secure, low-resistance connection.
  4. Field Connection (FIELD): Connect the alternator field wire to the terminal labeled "FIELD". This connection allows the Alpha Pro III to control the alternator's output.
  5. Masseanschluss (GND): Connect the ground cable to the terminal labeled "GND". A solid ground connection is essential for safety and performance.
  6. Datenverbindungen: Utilize the RJ45-like ports for communication with other Mastervolt devices or system monitoring, if applicable. Refer to your system's specific wiring diagram for these connections.
  7. Einschalten: Once all connections are verified and secure, reconnect the battery power. Observe the indicator lights for initial status.

For detailed wiring diagrams and specific system configurations, please refer to the comprehensive installation guide available on the Mastervolt website or contact Mastervolt technical support.

Bedienungsanleitung

The Alpha Pro III operates largely automatically once correctly installed. It continuously monitors battery voltage and temperature to optimize the charging profile.

Wartung

The Mastervolt Alpha Pro III is designed for minimal maintenance. However, periodic checks can help ensure its long-term reliability.

Fehlerbehebung

If you encounter issues with your Alpha Pro III, refer to the following common troubleshooting steps:

ProblemMögliche UrsacheLösung
Keine LadeleistungLoose connections, blown fuse, alternator issue, or unit fault.Check all wiring connections. Inspect system fuses. Verify alternator operation. If issues persist, contact support.
Rote LED leuchtetÜberlautstärketage, over-temperature, or internal fault.Überprüfen Sie die Batterieladungtage. Ensure adequate ventilation. Disconnect power, wait 5 minutes, and reconnect. If error persists, seek professional assistance.
Inaccurate chargingFaulty temperature sensor or incorrect battery settings.Verify temperature sensor connection and integrity. Ensure battery type and capacity settings (if configurable) are correct.

For more complex issues or if the problem cannot be resolved using these steps, please contact Mastervolt technical support.

Technische Daten

AttributWert
MarkeMastervolt
Modellname45513000
Teilenummer45513000
UPC816882020377
Artikelgewicht2.38 Pfund
Artikelabmessungen (LxBxH)9.75 x 6.5 x 3 Zoll
MaterialPlastik
FarbeKeine Farbe
Datum der ersten Verfügbarkeit9. Juli 2020
Bestseller-Rang#33 in Photographic Lighting Power Packs

Garantieinformationen

The Mastervolt Alpha Pro III comes with a manufacturer's warranty. For specific details regarding the warranty period, coverage, and terms, please refer to the official warranty documentation included with your product or visit the Mastervolt webBewahren Sie Ihren Kaufbeleg für Garantieansprüche auf.

Support und Kontakt

For technical assistance, product inquiries, or warranty claims, please contact Mastervolt customer support. You can find contact information, including phone numbers and email addresses, on the official Mastervolt webWebsite.

Mastervolt Offiziell WebWebsite: www.mastervolt.com

When contacting support, please have your product model number (45513000) and serial number (J824H 1002, if applicable) ready to expedite the process.

Zugehörige Dokumente - 45513000

Vorview Mastervolt Alpha Pro Bedienungs- und Installationsanleitung: Leitfaden für Laderegler
Diese Anleitung bietet detaillierte Informationen zur Installation, Bedienung und Wartung des Mastervolt Alpha Pro Ladereglers. Erfahren Sie mehr über die 3-Stufen-Ladetechnologie, MasterBus-Integration und Fehlerbehebung für optimale Leistung Ihrer Lichtmaschine und Batterien.
Vorview CZone MasterBus Bridge Interface – Kurzanleitung zur Installation | Mastervolt
Mastervolts Kurzanleitung zur Installation des CZone MasterBus Bridge Interface (MBI). Erfahren Sie mehr über sichere Installation, Verkabelung und Einrichtung von Schiffselektronik. Modell 80-911-0072-00.
Vorview Handbuch des Fernsteuerungspanels Mastervolt REMOTE ICC
Benutzerhandbuch für das ferngesteuerte Bedienfeld Mastervolt REMOTE ICC, inklusive Installation, Betrieb, Sicherheit und Garantie.
Vorview Mastervolt Amperian Interface: Allgemeine Hinweise, Gewährleistung, Haftung und Verwendungszweck
Umfassender Leitfaden zum Mastervolt Amperian Interface mit allgemeinen Hinweisen, Garantiebedingungen, Haftung, bestimmungsgemäßer Verwendung, Installationsrichtlinien und Entsorgungshinweisen. Gewährleisten Sie einen sicheren und effektiven Betrieb.
Vorview Mastervolt Mass Combi Pro Installations- und Bedienungsanleitung
Dieses Handbuch enthält detaillierte Anweisungen zur Installation, Bedienung und Wartung der Wechselrichter-/Ladegerätkombinationen Mass Combi Pro 12/3000-150 und 24/3500-100 von Mastervolt.
Vorview Guide Rapida App CZONE Mastervolt: Controllo e Monitoraggio Imbarcazioni
Nutzen Sie die CZONE-App von Mastervolt, um Ihr elektrisches System auf Ihrem iPad zu steuern und zu überwachen. Eine schnelle, vollständige Anleitung für die Leitung, Überwachung und Alarmierung.