1. Produktüberschreitungview
The EXCEL Tankless Gas Water Heater is designed to provide instant hot water for various applications, including small apartments, lofts, flats, RVs, and mobile homes. This unit operates on Propane (LPG) and features exclusive low water pressure startup technology, requiring only 2 PSI of water pressure to activate. Its vent-free design eliminates the need for complex and costly flue installations, making it a convenient and energy-efficient solution for on-demand hot water.

Abbildung 1.1: Vorder- und Seitenansicht view of the EXCEL Tankless Gas Water Heater, showcasing sein kompaktes Design und die Bedienknöpfe.
Hauptmerkmale:
- Propane Gas (LPG) Unit: Designed for use with liquid propane gas.
- Low Water Pressure Startup: Activates with as little as 2 PSI of water pressure, ideal for areas with fluctuating water supply. This is achieved through a magnetic water flow sensor, unlike older units that rely on rubber diaphragms requiring higher pressure.
- Vent-Free Technology: Does not require a traditional flue or ductwork for exhaust. Equipped with an Oxygen Depletion Safety (ODS) shutoff and an exclusive 20-minute safety shutoff feature for indoor installation with proper ventilation.
- Kompakte Größe: Dimensions are approximately 12.8 inches (front width) x 8 inches (depth) x 18.75 inches (height), allowing for flexible installation.
- Automatische Zündung: Powered by 2 D-size batteries (included) for automatic ignition upon water flow.
- Energie- und Wassereinsparung: Delivers hot water instantly, reducing waste.
2. Sicherheitshinweise
Read and understand all safety warnings and instructions before installing, operating, or performing maintenance on this appliance. Failure to follow these instructions could result in property damage, personal injury, or death.
Allgemeine Sicherheitsvorkehrungen:
- Dieses Gerät muss von einem qualifizierten Fachmann gemäß allen örtlichen Vorschriften und Bestimmungen installiert werden.
- Ensure adequate ventilation when installing the unit indoors due to its vent-free design.
- Lagern oder verwenden Sie kein Benzin oder andere brennbare Dämpfe und Flüssigkeiten in der Nähe dieses oder anderer Geräte.
- Check for gas leaks using a soapy water solution after installation and during maintenance. Never use an open flame.
- The unit is equipped with an Oxygen Depletion Safety (ODS) shutoff system and a 20-minute safety shutoff feature. Do not bypass or tampmit diesen Sicherheitseinrichtungen.
- Ensure proper battery installation for automatic ignition. Use new, high-quality D-size alkaline batteries.
- Protect the unit from freezing temperatures. Drain the unit if it will be exposed to freezing conditions (see Maintenance section).
- Dieses Produkt enthält Chemikalien, die dem Staat Kalifornien als krebserregend und fortpflanzungsschädigend bekannt sind (Warnung gemäß Proposition 65).
3. Einrichtung und Installation
Proper installation is critical for the safe and efficient operation of your EXCEL Tankless Gas Water Heater. Refer to the diagrams below for connection points.
Komponentenidentifikation:

Figure 3.1: Connection points at the bottom of the unit.

Figure 3.2: Location of the Winter Drain and Battery Box.
Installationsschritte:
- Montage: Securely mount the unit to a wall using appropriate hardware. Ensure the mounting surface can support the weight of the unit when filled with water.
- Wasseranschlüsse:
- Connect the cold water supply line to the Kaltwassereinlass.
- Connect the hot water output line to the Warmwasserauslass.
- Ensure all water connections are tight and leak-free. Use appropriate sealing tape or compound.
- Gasanschluss:
- Connect the Propane (LPG) gas supply line to the Gaseinlass. The unit includes an LPG Brass Fitting for a ⅜" Flare connection.
- Verify all gas connections are secure and test for leaks using a soapy water solution.
- Einlegen der Batterie: Open the battery box and insert two D-size batteries. Ensure correct polarity. These batteries power the automatic ignition system.
- Belüftung: For indoor installations, ensure the area has adequate ventilation as this is a vent-free appliance.

Abbildung 3.3: Intern view highlighting the magnetic water flow sensor, which enables low water pressure startup.
4. Bedienungsanleitung
Follow these steps to operate your EXCEL Tankless Gas Water Heater.
Erstinbetriebnahme:
- Ensure all water and gas connections are properly made and leak-free.
- Öffnen Sie das Hauptgaszufuhrventil.
- Open a hot water faucet in your system. The unit will detect water flow (as low as 2 PSI) and automatically ignite.
- Allow water to run for a few moments to purge any air from the lines.
Tägliche Operation:
- To get hot water, simply open any hot water faucet connected to the unit. The heater will automatically ignite and begin heating water as it flows through.
- The unit is designed for a temperature rise of approximately 45°F, delivering 1.6 Gallons Per Minute (GPM).
- While suitable for multiple points of use, it is recommended to use no more than one point of use at a time for optimal performance.
- For incoming cold water temperatures below 50°F (down to 40°F), you may need to reduce the water flow rate using the control knob to achieve desired hot water temperature.
- The unit features a 20-minute safety shutoff. If hot water is continuously drawn for more than 20 minutes, the unit will automatically shut off. To restart, close the hot water faucet and then reopen it.
5. Wartung
Regelmäßige Wartung gewährleistet die Langlebigkeit und den effizienten Betrieb Ihres Warmwasserbereiters.
Routinekontrollen:
- Batteriewechsel: Replace the two D-size batteries annually, or if the ignition becomes inconsistent. Use high-quality alkaline batteries.
- Dichtheitsprüfung: Periodically check all water and gas connections for leaks. For gas leaks, use a soapy water solution.
- Außenreinigung: Reinigen Sie das Äußere des Geräts mit einem weichen, damp Tuch. Keine Scheuer- oder Lösungsmittel verwenden.
Winterization (Freezing Protection):
If the unit will be exposed to freezing temperatures, it is crucial to drain all water from the system to prevent damage.
- Schalten Sie die Gaszufuhr zum Gerät ab.
- Schalten Sie die Kaltwasserzufuhr zum Gerät ab.
- Open a hot water faucet in your system to relieve pressure.
- Suchen Sie die Winter Drain valve at the bottom of the unit (refer to Figure 3.2). Open this valve to drain the water from the heat exchanger.
- Once drained, close the drain valve.

Abbildung 5.1: Intern view of the copper heat exchanger, which should be drained to prevent freezing damage.
6. Fehlerbehebung
This section provides solutions to common issues you might encounter with your water heater.
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Kein Warmwasser / Gerät zündet nicht | No water flow or insufficient water pressure | Ensure water supply is on and water pressure is at least 2 PSI. Check for kinks in water lines. |
| Leere oder schwache Batterien | Replace both D-size batteries with new alkaline batteries. | |
| Keine Gasversorgung | Ensure gas tank is not empty and gas supply valve is fully open. | |
| ODS or 20-minute safety shutoff activated | Ensure adequate ventilation. If unit ran for 20 minutes, close and reopen hot water faucet to reset. | |
| Das Wasser ist nicht heiß genug | High water flow rate for incoming temperature | Reduce water flow rate using the control knob on the unit. |
| Niedrige Temperatur des einströmenden Wassers | The unit adds approximately 45°F to incoming water. If incoming water is very cold, the output temperature will be lower. Reduce flow rate. | |
| Gas or water leaks | Lose Verbindungen oder beschädigte Komponenten | Tighten all connections. If leaks persist, contact a qualified professional for inspection and repair. Do not attempt to repair gas leaks yourself. |
Wenn das Problem nach dem Ausprobieren dieser Lösungen weiterhin besteht, wenden Sie sich an einen qualifizierten Servicetechniker.
7. Spezifikationen
Technical specifications for the EXCEL Tankless Gas Water Heater.

Abbildung 7.1: Produktetikett mit detaillierten Spezifikationen.
| Spezifikation | Wert |
|---|---|
| Marke | EXCEL |
| Modellnummer | 850020757060 |
| Produktabmessungen (B x T x H) | 12.8" x 8" x 18.75" (ca.) |
| Artikelgewicht | 8.6 Pfund |
| Kraftstoffart | Propan (LPG) |
| Bandtage | 3 Volts (for ignition) |
| Batterien erforderlich | 2 D-size batteries |
| Maximaler Durchfluss | 1.6 Gallonen pro Minute (GPM) |
| Wärmeabgabe | 40,000 British Thermal Units (BTU) |
| Temperaturanstieg | Adds approximately 45°F to cold water |
| Minimum Water Pressure Startup | 2 PSI |
| Maximaler Betriebsdruck | 120 PSI |
| Sicherheitsfunktionen | Oxygen Depletion Safety (ODS) shutoff, 20-minute safety shutoff |
| Montagetyp | Wandhalterung |
| Im Lieferumfang enthaltene Komponenten | 2 Size D Batteries, Exhaust diffuser Plate, LPG Brass Fitting for ⅜" Flare connection |
8. Garantie und Support
For warranty information and technical support, please refer to the documentation included with your purchase or contact the seller directly. The seller for this product is typically Energy-Store.
For additional resources and product information, you may visit the official EXCEL webWebsite: www.excelonlinestore.com